← Back
Two family frame
150-04 109 DRIVE
QUEENS · BIN 4464067
💬 Discuss this project
2002Year Built
2Stories
B2Building Class
R5DZoning
1,760 sfGross Floor Area
2Units
Rent Stabilized3 Open Violations ▸FDNY Report ↗
Two family frame · Owner of record: 150-04 109 DR. LLC · 1,960 sf lot · 0.9 FAR built · Flood zone X
Locations of Work
ArchitectureFire Protection
Floor 31p · 1 filing · 20 docs
Floor 2
Floor 1
Cellar2p · 1 filing · 20 docs
1 job · most recent 06/25/2025
Heating and Air Conditioning Systems
FiledStatusContractorScope
06/25/2025——Heating and Air Conditioning Systems
1 job · most recent 06/25/2025
Sprinkler System
FiledStatusContractorScope
06/25/2025——Sprinkler System
1 job · most recent 06/25/2025
Steel Concrete
FiledStatusContractorScope
06/25/2025——Steel, Concrete
Building Lifecycle
All (54)Filed (4)Violation (17)Objection (23)Special Inspection (10)
11/25/2025
Violation issued (HPD, closed)
I
10/03/2025
Objection raised — Admin
09/26/2025
Objection resolved — Addressed
09/17/2025
Objection raised — Energy
09/02/2025
Objection resolved — Addressed
09/02/2025
Objection resolved — Addressed
09/02/2025
Objection resolved — Addressed
09/02/2025
Special inspection requirement — Permanent certificate
09/02/2025
Special inspection requirement — Air barrier — testing
09/02/2025
Special inspection requirement — Fenestration and door U-factor and product ratings
09/02/2025
Special inspection requirement — Fenestration air leakage
09/02/2025
Special inspection requirement — Fenestration areas
09/02/2025
Special inspection requirement — Air barrier - visual inspection
09/02/2025
Special inspection requirement — Insulation placement and R values
08/22/2025
Filed — Alteration
Q01275571-I1
08/18/2025
Objection resolved — Addressed
07/11/2025
Objection raised — Cost
07/11/2025
Objection raised — Admin
07/11/2025
Objection raised — Structural
07/01/2025
Objection resolved — Addressed
07/01/2025
Objection resolved — Addressed
06/25/2025
Filed — ALT-CO - New Building with Existing Elements to Remain
HEREWITH FILING FOR HYDRAULICALLY CALCULATED SPRINKLER SYSTEM THROUGH-OUT BUILDING. FILED IN CONJUNCTION WITH ALT TYPE 1, DOB NOW #Q01194626.
Q01194626-S3
06/18/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
06/16/2025
Objection raised — Fire_Protection
06/16/2025
Objection raised — Fire_Protection
06/03/2025
Filed — ALT-CO - New Building with Existing Elements to Remain
HEREWITH FILING FOR HYDRAULICALLY CALCULATED SPRINKLER SYSTEM THROUGH-OUT BUILDING. FILED IN CONJUNCTION WITH ALT TYPE 1, DOB NOW #Q01194626.
Q01194626-S1
05/27/2025
Objection resolved — Addressed
05/27/2025
Objection resolved — Addressed
05/27/2025
Objection resolved — Addressed
05/27/2025
Objection resolved — Addressed
05/05/2025
Objection raised — Zoning
05/05/2025
Objection raised — Admin
05/05/2025
Objection raised — Zoning
05/05/2025
Objection raised — Zoning
04/10/2025
Objection raised — Admin
04/04/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
04/02/2025
Special inspection requirement — Sprinkler Systems
03/27/2025
Filed — ALT-CO - New Building with Existing Elements to Remain
HEREWITH FILING FOR HYDRAULICALLY CALCULATED SPRINKLER SYSTEM THROUGH-OUT BUILDING. FILED IN CONJUNCTION WITH ALT TYPE 1, DOB NOW #Q01194626.
Q01194626-I1
04/22/2021
Violation issued (HPD, closed)
I
06/01/2014
Violation issued (HPD, closed)
C
06/01/2014
Violation issued (HPD, open)
C
06/01/2014
Violation issued (HPD, open)
B
06/01/2014
Violation issued (HPD, closed)
C
08/17/2011
Violation issued (HPD, closed)
B
08/17/2011
Violation issued (HPD, closed)
C
08/17/2011
Violation issued (HPD, closed)
B
08/17/2011
Violation issued (HPD, open)
B
02/17/2009
Violation issued (ECB, closed)
Construction
02/13/2009
Violation issued (ECB, closed)
Unknown
02/13/2009
Violation issued (ECB, closed)
Construction
02/13/2009
Violation issued (ECB, closed)
Unknown
06/27/2002
Violation issued (DOB, closed)
VPW*-VIOLATION UNSERVED ECB-WORK WITHOUT PERMIT-DISMISSED
06/27/2002
Violation issued (ECB, closed)
Construction
11/12/1992
Violation issued (DOB, closed)
VP*-VIOLATION UNSERVED ECB- DISMISSED
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
OWNER OF 104-51 STUPHIN B103/22/2026
EXCLUSIVE HOME CONSTRUCTION403/21/2026
150-04 109 DR103/21/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
01/18/2018$485K—— → —$276/sf building
▾Design Consultants (Architect / Engineer of Record)
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
ARNOLD MONTAG ARCHITECT AM PM DESI203/21/2026
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
BIS—ISSUEDKEREN' CONSTRUCTION & DEVELOPMEN10/09/2002
BIS—ISSUEDOWNER07/19/2002
▾Special Inspection Requirements (DOB NOW) — 10
DateRequirementInspectorRole
09/02/2025Permanent certificate—energy_progress
09/02/2025Air barrier — testing —energy_progress
09/02/2025Fenestration and door U-factor and product ratings—energy_progress
09/02/2025Fenestration air leakage—energy_progress
09/02/2025Fenestration areas—energy_progress
09/02/2025Air barrier - visual inspection—energy_progress
09/02/2025Insulation placement and R values—energy_progress
06/18/2025Structural Stability – Alterations of existing buildings—special
04/04/2025Fire-Resistant Penetrations and Joints—special
04/02/2025Sprinkler Systems—special
▾Documents — 24 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch4
08/20/2026Q01194626-S3Request digital key ↗
08/19/2026Q01275571-I1Request digital key ↗
08/15/2026Q01194626-I1Request digital key ↗
Showing 3 of 4 on file for this type
▸Zoning, Tax Lot & Property Records3
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026Q01194626-I1Open ↗
▸DOB NOWZD1: DOB Zoning Diagram1
08/13/2026Q01194626-I1Open ↗
▸DOB NOWZoning Exhibit form (1-5)1
08/13/2026Q01194626-I1Open ↗
▸Seals & Professional Certifications4
▸DOB NOWDPL-1: Design Professional Seal & Signature4
08/20/2026Q01194626-S3Open ↗
08/20/2026Q01194626-I1Open ↗
08/20/2026Q01194626-S1Open ↗
Showing 3 of 4 on file for this type
▸Safety & Tenant Protection3
▸DOB NOWParks Department Acknowledgment Letter for Street Trees Plan2
08/13/2026Q01194626-I1Open ↗
08/13/2026Q01194626-S3Open ↗
▸DOB NOWStreet Tree Sign Off1
08/15/2026Q01194626-I1Open ↗
▸Environmental & Asbestos3
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
08/20/2026Q01194626-S3Open ↗
08/15/2026Q01194626-I1Open ↗
08/14/2026Q01194626-S1Open ↗
▸Inspections & Test Reports2
▸DOB NOWTR4 Test Report and Plot Diagram1
08/13/2026Q01194626-I1Open ↗
▸DOB NOWSOIL REPORT1
08/13/2026Q01194626-I1Open ↗
▸Other Documents5
▸DOB NOWSite Survey: Initial2
08/13/2026Q01194626-S3Open ↗
08/13/2026Q01194626-I1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone2
08/13/2026Q01194626-I1Open ↗
08/13/2026Q01194626-S3Open ↗
▸DOB NOWProperty Ownership Certification1
08/15/2026Q01194626-I1Open ↗