← Back
Predominantly retail with other uses
150-10 BEAVER ROAD
QUEENS · BIN 4607442
💬 Discuss this project
2021Year Built
1Stories
K4Building Class
M1-2A/R7-2Zoning
9,868 sfGross Floor Area
1Units
0 Open ViolationsFDNY Report ↗
Predominantly retail with other uses · Owner of record: BEAVER ROAD MANAGEMENT LLC · 25,545 sf lot · 0.39 FAR built · Flood zone X
Locations of Work
StructuralMechanicalFire Protection
Roof2p · 2 filings · 18 docs
Floor 12p · 2 filings · 18 docs
Mezzanine4p · 3 filings · 20 docs
Cellar3p · 2 filings · 17 docs
2 jobs · most recent 01/12/2023
General Wiring
FiledStatusContractorScope
01/12/2023CompleteRICHARD NEUGeneral Wiring
02/18/2020CompleteRICHARD NEU—
Building Lifecycle
All (50)Filed (8)Permit Issued (5)Signed Off (4)Violation (11)Inspection (3)Special Inspection (19)
11/19/2025
Violation issued (FDNY_NOV, closed)
04/26/2023
Signed off — Alteration
INSTALLATION OF SPRINKLER SYSTEMS INCONJUNCTION WITH NB APPLICATION# 421583922. NO CHANGE IN USE, EGRESS OR OCCUPANCY
Q00599951-I1
03/27/2023
Signed off — Alteration
INSTALLATION OF MECHANICAL SYSTEMS- HEATING & COOLING SYSTEM FILED INCONJUNCTION WITH NB JOB#421583922 . NO CHANGE IN USE, EGRESS OCCUPANCY.
Q00479555-I1
02/23/2023
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
02/21/2023
Permit issued — Sprinklers
Q00599951-I1-PL
02/15/2023
Signed off — Alteration
THIS APPLICATION IS FILED FOR STRUCTURAL IN CONJUNCTION WITH NB JOB#421583922. NO CHANGE IN USE, OCCUPANCY AND AN EGRESS IS INVOLVED UNDER THIS APPLICATION
Q00303574-I1
02/05/2023
Special inspection requirement — Final
Sunil Saigal
02/05/2023
Special inspection requirement — Mechanical Systems
Victor Suben
02/02/2023
Filed — Alteration
INSTALLATION OF MECHANICAL SYSTEMS- HEATING & COOLING SYSTEM FILED INCONJUNCTION WITH NB JOB#421583922 . NO CHANGE IN USE, EGRESS OCCUPANCY.
Q00479555-P2
02/02/2023
Special inspection requirement — Mechanical Systems
Victor Suben
02/02/2023
Special inspection requirement — Final
Sunil Saigal
09/21/2022
Inspection — Certified Sprinkler-SP-Fixtures-Finish
Certified
View inspection ↗
09/19/2022
Permit issued — Mechanical Systems
Q00479555-I1-MS
09/19/2022
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
08/28/2022
Special inspection requirement — Sprinkler Systems
Victor Suben
08/28/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
Victor Suben
08/22/2022
Filed — Alteration
INSTALLATION OF SPRINKLER SYSTEMS INCONJUNCTION WITH NB APPLICATION# 421583922. NO CHANGE IN USE, EGRESS OR OCCUPANCY
Q00599951-P1
02/03/2022
Filed — Alteration
INSTALLATION OF MECHANICAL SYSTEMS- HEATING & COOLING SYSTEM FILED INCONJUNCTION WITH NB JOB#421583922 . NO CHANGE IN USE, EGRESS OCCUPANCY.
Q00479555-P1
02/03/2022
Special inspection requirement — Mechanical Systems
02/03/2022
Special inspection requirement — Final
11/16/2021
Permit issued — Sprinklers
Q00599951-I1-EW-SP
09/29/2021
Filed — Alteration
INSTALLATION OF SPRINKLER SYSTEMS INCONJUNCTION WITH NB APPLICATION# 421583922. NO CHANGE IN USE, EGRESS OR OCCUPANCY
Q00599951-I1
06/15/2021
Violation issued (ECB, closed)
Construction
04/27/2021
Filed — Alteration
INSTALLATION OF MECHANICAL SYSTEMS- HEATING & COOLING SYSTEM FILED INCONJUNCTION WITH NB JOB#421583922 . NO CHANGE IN USE, EGRESS OCCUPANCY.
Q00479555-I1
03/05/2021
Signed off — Alteration
INSTALLATION OF TEMPORARY HEAVY DUTY SIDEWALK SHED AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.SIDEWALK SHED SHALL COMPLY WITH CHAPTER #33 OF THE NYC BUILDING CODE.LIVE LOAD 300PSF.
Q00316994-I1
07/22/2020
Violation issued (ECB, closed)
Unknown
02/28/2020
Special inspection requirement — Final
BRIAN T. O'CONNOR
02/26/2020
Filed — Alteration
INSTALLATION OF TEMPORARY HEAVY DUTY SIDEWALK SHED AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.SIDEWALK SHED SHALL COMPLY WITH CHAPTER #33 OF THE NYC BUILDING CODE.LIVE LOAD 300PSF.
Q00316994-P1
02/18/2020
Filed — Alteration
INSTALLATION OF TEMPORARY HEAVY DUTY SIDEWALK SHED AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.SIDEWALK SHED SHALL COMPLY WITH CHAPTER #33 OF THE NYC BUILDING CODE.LIVE LOAD 300PSF.
Q00316994-I1
02/18/2020
Permit issued — Sidewalk Shed
Q00316994-I1-SH
01/31/2020
Permit issued — Structural
Q00303574-I1-ST
01/28/2020
Filed — Alteration
THIS APPLICATION IS FILED FOR STRUCTURAL IN CONJUNCTION WITH NB JOB#421583922. NO CHANGE IN USE, OCCUPANCY AND AN EGRESS IS INVOLVED UNDER THIS APPLICATION
Q00303574-I1
01/25/2020
Special inspection requirement — Structural Steel - Details
Sunil Saigal
01/25/2020
Special inspection requirement — Energy Code Compliance Inspections
Sunil Saigal
01/25/2020
Special inspection requirement — Subgrade Inspections
Sunil Saigal
01/25/2020
Special inspection requirement — Structural Steel - Welding
Sunil Saigal
01/25/2020
Special inspection requirement — Structural Steel - High Strength Bolting
Sunil Saigal
01/25/2020
Special inspection requirement — Structural Stability – Alterations of existing buildings
Sunil Saigal
01/25/2020
Special inspection requirement — Seismic Isolation Systems
Sunil Saigal
01/25/2020
Special inspection requirement — Masonry
Sunil Saigal
01/25/2020
Special inspection requirement — Concrete - Cast-In-Place
Sunil Saigal
01/24/2020
Special inspection requirement — Final
Sunil Saigal
06/08/2007
Violation issued (ECB, closed)
Construction
03/21/2007
Violation issued (ECB, closed)
Construction
03/20/2007
Violation issued (DOB, closed)
VW*-VIOLATION - WORK W/O PERMIT DISMISSED
09/23/2005
Violation issued (ECB, closed)
Construction
05/05/2005
Violation issued (ECB, closed)
Construction
01/24/2005
Violation issued (ECB, closed)
Construction
08/27/2004
Violation issued (ECB, closed)
Construction
06/03/1995
Violation issued (ECB, closed)
Construction
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
TRIERA CONTRACTING3107/08/2026
BEAVER ROAD MANAGEMENT303/22/2026
METRO CONTRACTING NY1003/21/2026
L B MANAGEMENT1203/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
VS CONSULTING ENGINEERING, PC502/02/2023
GREEN DESIGN202/26/2020
ENTHINK ENGINEERS LLC101/28/2020
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
ROYAL BUILDERS GROUP1003/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
TRIERA CONTRACTING INCGeneral Contractor603/21/2026
HORBRIDGE PLUMBING & HEATINGPlumbing203/22/2026
LLOYD G DRUMMOND PLBG&GENPlumbing207/08/2026
DYNAMIC PLBNG & SPRKR CORFire Protection107/08/2026
METRO CONTRACTING NY, INC.General Contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
VICTOR SUBEN6672402/02/2023
ENTHINK ENGINEERS LLC6247101/28/2020
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSprinklersSigned-offLLOYD G DRUMMOND PLBG&GEN02/21/2023
DOB NOWMechanical SystemsSigned-offMETRO CONTRACTING NY, INC.09/19/2022
DOB NOWSprinklersSigned-offCITYWIDE PLBG, HTG &SPRKL11/16/2021
DOB NOWSidewalk ShedSigned-offTRIERA CONTRACTING INC02/18/2020
DOB NOWStructuralSigned-offTRIERA CONTRACTING INC01/31/2020
BISPLISSUEDHORBRIDGE PLUMBING & HEATING12/07/2022
BIS—ISSUEDMETRO CONTRACTING NY, INC.10/17/2022
BISPLISSUEDHORBRIDGE PLUMBING & HEATING09/21/2021
BIS—ISSUEDMETRO CONTRACTING NY, INC.09/20/2021
BISEQISSUEDMETRO CONTRACTING NY, INC.03/05/2021
BIS—ISSUEDMETRO CONTRACTING NY, INC.03/04/2020
BISEQISSUEDMETRO CONTRACTING NY, INC.02/26/2020
BIS—ISSUEDMETRO CONTRACTING NY, INC.06/04/2019
BISEQISSUEDMETRO CONTRACTING NY, INC.09/28/2018
BISEQISSUEDMETRO CONTRACTING NY, INC.07/07/2017
BISOTISSUEDB H & B CONSTRUCTION INC07/03/2013
BISEQISSUEDMETRO CONTRACTING NY, INC.06/17/2011
BISOTISSUEDMETRO CONTRACTING NY, INC.06/17/2011
BISCCISSUEDMETRO CONTRACTING NY, INC.04/12/2011
BISCCISSUEDMETRO CONTRACTING NY, INC.04/12/2011
BISPLISSUEDCHINATOWN PLBG & HTG INC01/20/2000
BISOTISSUEDDUN-RITE WATERMAIN & SEWER11/17/1999
▾Field Inspections (DOB CAP) — 3
DateTypeResultReport
02/23/2023Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
09/21/2022Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
09/19/2022Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 19
DateRequirementInspectorRole
02/05/2023FinalSunil Saigalprogress
02/05/2023Mechanical SystemsVictor Subenspecial
02/02/2023Mechanical SystemsVictor Subenspecial
02/02/2023FinalSunil Saigalprogress
08/28/2022Sprinkler SystemsVictor Subenspecial
08/28/2022Fire-Resistant Penetrations and JointsVictor Subenspecial
02/03/2022Mechanical Systems—special
02/03/2022Final—progress
02/28/2020FinalBRIAN T. O'CONNORprogress
01/25/2020Structural Steel - DetailsSunil Saigalspecial
01/25/2020Energy Code Compliance InspectionsSunil Saigalprogress
01/25/2020Subgrade InspectionsSunil Saigalspecial
01/25/2020Structural Steel - WeldingSunil Saigalspecial
01/25/2020Structural Steel - High Strength BoltingSunil Saigalspecial
01/25/2020Structural Stability – Alterations of existing buildingsSunil Saigalspecial
01/25/2020Seismic Isolation SystemsSunil Saigalspecial
01/25/2020MasonrySunil Saigalspecial
01/25/2020Concrete - Cast-In-PlaceSunil Saigalspecial
01/24/2020FinalSunil Saigalprogress
▾Documents — 304 on file (BIS + DOB NOW)
▸Plans & Drawings8
▸DOB NOWPlans/Sketch5
08/25/2026Q00599951-I1Request digital key ↗
08/25/2026Q00599951-P1Request digital key ↗
08/25/2026Q00479555-I1Request digital key ↗
Showing 3 of 5 on file for this type
▸DOB NOWPlans/Sketch - Sidewalk Shed2
08/28/2026Q00316994-I1Request digital key ↗
08/15/2026Q00316994-P1Request digital key ↗
▸DOB NOWPlans/Sketch - Structural1
08/28/2026Q00303574-I1Request digital key ↗
▸Applications & Permits63
▸BISPLAN / WORK APPROVAL APPLICATION49
10/29/2025420301845Open ↗
09/06/2023421583922Open ↗
09/05/2023421583922Open ↗
Showing 3 of 49 on file for this type
▸BISWORK PERMIT APPLICATION11
09/20/2021421583922Open ↗
09/20/2021421583922Open ↗
03/13/2020421583922Open ↗
Showing 3 of 11 on file for this type
▸BISBPP-5 - Authorization to the Department of Transportation3
09/30/2022421812747Open ↗
Showing 1 of 3 on file for this type
▸Zoning, Tax Lot & Property Records7
▸BISZONING DIAGRAM3
05/31/2019421583922Open ↗
02/20/2018421257981Open ↗
Showing 2 of 3 on file for this type
▸BISTAX LOT: TENTATIVE LOT NUMBER ISSUED2
12/15/2017421583922Open ↗
Showing 1 of 2 on file for this type
▸BISEASEMENT AND RESTRICTIVE DECLARATIONS - SUPPPORTING DOCUMENTATION2
03/19/2019421583922Open ↗
03/19/2019421583922Open ↗
▸Seals & Professional Certifications42
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION12
06/06/2019421583922Open ↗
05/30/2019421257981Open ↗
12/15/2017421583922Open ↗
Showing 3 of 12 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature12
09/02/2026Q00479555-P2Open ↗
08/25/2026Q00599951-I1Open ↗
08/25/2026Q00599951-I1Open ↗
Showing 3 of 12 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature8
08/28/2026Q00316994-P1Open ↗
08/28/2026Q00316994-I1Open ↗
08/25/2026Q00599951-P1Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWProgress Inspector Seal & Signature5
09/02/2026Q00479555-P2Open ↗
08/30/2026Q00316994-I1Open ↗
08/25/2026Q00479555-I1Open ↗
Showing 3 of 5 on file for this type
▸BISPROFESSIONAL CERTIFIED CHECKLIST2
09/30/2022421812747Open ↗
Showing 1 of 2 on file for this type
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY2
04/25/2022440714283Open ↗
07/03/2017440416701Open ↗
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION1
07/03/2017440416701Open ↗
▸Trade Schedules & Equipment12
▸BISSCHEDULE B - PLUMBING7
06/30/2022421583922Open ↗
06/29/2022421583922Open ↗
06/03/2022421583922Open ↗
Showing 3 of 7 on file for this type
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE3
12/15/2017421583922Open ↗
Showing 1 of 3 on file for this type
▸BISHVAC & SERVICE WATER HEATING EQUIPMENT1
10/14/2022421583922Open ↗
▸BISDEP SEWER CERTIFICATE (SD1 & SD2)1
11/01/2022421583922Open ↗
▸Safety & Tenant Protection11
▸BISSTREET TREE CHECKLIST9
09/30/2022421812747Open ↗
06/16/2022440714283Open ↗
04/25/2022440714283Open ↗
Showing 3 of 9 on file for this type
▸BISBPP: STREET TREES SITE PLAN2
09/30/2022421812747Open ↗
06/16/2022440714283Open ↗
▸Environmental & Asbestos4
▸BISASBESTOS EXEMPTION CERTIFICATION LETTER4
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 4 on file for this type
▸Energy Compliance13
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS3
06/06/2019421583922Open ↗
12/15/2017421583922Open ↗
06/14/2017421257981Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY2
10/14/2022421583922Open ↗
08/31/2021421583922Open ↗
▸BISAIR SEALING AND INSULATION - VISUAL1
10/14/2022421583922Open ↗
▸BISFENESTRATION AIR LEAKAGE1
10/14/2022421583922Open ↗
▸BISINTERIOR LIGHTING POWER1
10/14/2022421583922Open ↗
▸BISEXTERIOR LIGHTING POWER1
10/14/2022421583922Open ↗
▸BISFENESTRATION U-FACTOR & PRODUCT RATING1
10/14/2022421583922Open ↗
▸BISFENESTRATION AREAS1
10/14/2022421583922Open ↗
▸BISAIR SEALING AND INSULATION - TESTING1
10/14/2022421583922Open ↗
▸DOB NOWEN2: As Built Energy Analysis.1
08/13/2026Q00479555-I1Open ↗
▸Inspections & Test Reports21
▸BISTECHNICAL REPORT: RESPONSIBILITY7
01/12/2023401024299Open ↗
10/26/2022420026420Open ↗
10/17/2022420865406Open ↗
Showing 3 of 7 on file for this type
▸BISTECHNICAL REPORT: SOIL INSPECTION3
12/15/2017421583922Open ↗
Showing 1 of 3 on file for this type
▸BISSTRUCTURAL STABILITY - EXISTING BUILDINGS2
10/18/2022420026420Open ↗
10/14/2022421583922Open ↗
▸BISMASONRY2
10/18/2022420026420Open ↗
10/14/2022421583922Open ↗
▸BISSUBSURFACE / SOILS INVESTIGATION (BORINGS/TEST PITS)1
08/11/2023421583922Open ↗
▸BISFRAME (2008)/STRUCTURAL WOOD FRAME (2014) INSPECTION1
10/14/2022421583922Open ↗
▸BISFIRE-RESISTANT PENETRATIONS AND JOINTS (FIRESTOP)1
10/14/2022421583922Open ↗
▸BISTECHNICAL REPORT: CONCRETE/TEST CYLINDER1
06/08/2019421583922Open ↗
▸BISFIRE-RESISTIVE RATED CONSTRUCTION1
10/14/2022421583922Open ↗
▸BISFOOTING AND FOUNDATION INSPECTION1
10/14/2022421583922Open ↗
▸BISSOIL PERC. TEST-STORM WATER SYSTEM (DRYWELL)1
10/14/2022421583922Open ↗
▸Approvals, Objections & Sign-offs32
▸BISSCHEDULE A - OCCUPANCY / USE10
09/06/2023421583922Open ↗
09/05/2023421583922Open ↗
10/26/2022421583922Open ↗
Showing 3 of 10 on file for this type
▸BISADMINISTRATIVE OBJECTIONS9
02/14/2017421415640Open ↗
Showing 1 of 9 on file for this type
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST6
01/13/2023401024299Open ↗
01/10/2023420025387Open ↗
01/10/2023420025396Open ↗
Showing 3 of 6 on file for this type
▸BISLETTERS - SUPPORTING DOCUMENTATION3
02/01/2019421583922Open ↗
05/22/2017421257981Open ↗
Showing 2 of 3 on file for this type
▸BISFINAL2
10/17/2022420865406Open ↗
10/17/2022440416701Open ↗
▸BISBPP-UTILITY APPROVAL TO RELOCATE POLE1
06/30/2022440714283Open ↗
▸BISCURB CUT (CC) SIGNOFF1
08/07/2023421583922Open ↗
▸Cost, Insurance & Ownership11
▸BISPROJECT-SPECIFIC GL INSURANCE4
09/20/2021421583922Open ↗
03/13/2020421583922Open ↗
06/27/2019421583922Open ↗
Showing 3 of 4 on file for this type
▸BISCOST AFFIDAVIT3
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 3 on file for this type
▸BISCIVIL PENALTY AFFADAVIT/REQUEST2
07/07/2017440416701Open ↗
07/07/2017440416701Open ↗
▸BISCOST AFFIDAVIT (FINAL): PW32
10/21/2022420026420Open ↗
10/21/2022420865406Open ↗
▸Filing & Intake Forms33
▸BISEFILING COVER SHEET15
11/14/2022421812747Open ↗
05/01/2018421583922Open ↗
05/01/2018421583922Open ↗
Showing 3 of 15 on file for this type
▸BISADDITIONAL INFORMATION10
07/28/2023421812747Open ↗
09/30/2022421812747Open ↗
06/16/2022440714283Open ↗
Showing 3 of 10 on file for this type
▸BISBPP: CHECKLIST IN LIEU OF PLANS-ALT33
09/30/2022421812747Open ↗
04/25/2022440714283Open ↗
Showing 2 of 3 on file for this type
▸BISBOROUGH INTAKE FORM3
11/14/2022421812747Open ↗
11/03/2022421622417Open ↗
09/20/2021421583922Open ↗
▸BISEFILING JOB APPLICATION COVER SHEET2
04/25/2022440714283Open ↗
07/03/2017440416701Open ↗
▸Other Documents12
▸BISBPP - SUPPORTING DOCUMENTATION4
09/30/2022421812747Open ↗
09/30/2022421812747Open ↗
09/30/2022421812747Open ↗
Showing 3 of 4 on file for this type
▸BISPLOT DIAGRAM3
12/15/2017421583922Open ↗
Showing 1 of 3 on file for this type
▸BISLOWEST FLOOR ELEVATION1
10/14/2022421583922Open ↗
▸BISBPP: PHOTOS-SIGNED/SEALED BY APPLICANT1
06/16/2022440714283Open ↗
▸BISCURB CUT: PROVIDE EXISTING NUMBER1
06/30/2022440714283Open ↗
▸BIS* ENVIRONMENTAL 'E' DEP NOTICE OF SATISFACTION1
10/18/2022420026420Open ↗
▸BISRESTRICTION: DEED1
11/03/2022421622417Open ↗