← Back
BuildNYC
Two family frame
150-21 HAWTREE STREET
QUEENS · Ozone Park · BIN 4623567
💬 Discuss this project
2024Year Built
3Stories
B2Building Class
R3XZoning
2,573 sfGross Floor Area
2Units
0 Active ViolationsFDNY Report ↗
Two family frame · Owner of record: Vistah Group · 3,610 sf lot · 0.71 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralElectricalMechanicalPlumbingGeneral
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
RoofPhotovoltaic array on roof2p · 2 filings · 20 docs
Floor 318p · 1 filing · 20 docs
Floor 217p · 1 filing · 20 docs
Floor 158p · 1 filing · 20 docs
Cellar20p · 1 filing · 20 docs
Site & exteriorProposed 8' high plywood construction fence19p · 2 filings · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
Vistah Group1609/08/2026
Kamali Organization1608/29/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
05/27/2026$1.7M—Vistah Group → DONG FANG LLC$671/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
Arnold Montag Architect AM/PM Desi904/02/2026
Synergic Design Architects109/23/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
AM PM Design Consulting P603/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
Green JJ ManagementGeneral Contractor704/09/2026
Tri State Plumbing & HeatingPlumbing407/08/2026
Yafe MeodGeneral Contractor303/21/2026
Accord PowerGeneral Contractor203/21/2026
Green JJ ManagementScaffold207/08/2026
Planet Construction & de*General Contractor104/09/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
G Engineering7778404/02/2026
Synergic Design8561109/23/2024
Building Lifecycle
All (75)Filed (8)Permit Issued (14)Signed Off (5)Violation (2)Inspection (8)Objection (8)Special Inspection (30)
04/17/2026
Signed off — New Building
Proposed 2 family,3 story with Cellar
Q00478440-I1
04/09/2026
Special inspection requirement — Fire-Resistance Rated Construction
XIONGCAI GU
04/09/2026
Special inspection requirement — Permanent certificate
XIONGCAI GU
04/09/2026
Special inspection requirement — Structural Steel - Welding
XIONGCAI GU
04/09/2026
Special inspection requirement — Final
DENIS PORTAEV
04/09/2026
Special inspection requirement — Metering
XIONGCAI GU
04/09/2026
Special inspection requirement — Ventilation and air distribution system
XIONGCAI GU
04/09/2026
Special inspection requirement — Mechanical Systems
XIONGCAI GU
04/09/2026
Special inspection requirement — Concrete - Cast-In-Place
XIONGCAI GU
04/09/2026
Special inspection requirement — Structural Steel - Details
XIONGCAI GU
04/09/2026
Special inspection requirement — Structural Wood Frame
XIONGCAI GU
04/09/2026
Special inspection requirement — Insulation placement and R values
XIONGCAI GU
04/09/2026
Special inspection requirement — HVAC-R and service water heating equipment
XIONGCAI GU
04/09/2026
Special inspection requirement — Fenestration areas
XIONGCAI GU
04/09/2026
Special inspection requirement — Maintenance information
XIONGCAI GU
04/09/2026
Special inspection requirement — Masonry
XIONGCAI GU
04/09/2026
Special inspection requirement — Wood – Prefabricated I-Joists
XIONGCAI GU
04/09/2026
Special inspection requirement — Exterior Insulation and Finish Systems (EIFS)
XIONGCAI GU
04/09/2026
Special inspection requirement — Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation
XIONGCAI GU
04/09/2026
Special inspection requirement — Structural Cold-Formed Steel
XIONGCAI GU
04/09/2026
Special inspection requirement — Subgrade Inspections
XIONGCAI GU
04/09/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
XIONGCAI GU
04/09/2026
Special inspection requirement — Subsurface Investigations (Borings/Test Pits)
ROBERT DYKSTRA
04/09/2026
Special inspection requirement — Energy Code Compliance Inspections
XIONGCAI GU
04/09/2026
Special inspection requirement — Footing and Foundation
XIONGCAI GU
04/09/2026
Special inspection requirement — Fenestration air leakage
XIONGCAI GU
04/09/2026
Special inspection requirement — Interior lighting power
XIONGCAI GU
04/09/2026
Special inspection requirement — HVAC-R and service water heating system controls
XIONGCAI GU
04/09/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
XIONGCAI GU
04/09/2026
Special inspection requirement — Air barrier — testing
XIONGCAI GU
04/09/2026
Special inspection requirement — Air barrier - visual inspection
XIONGCAI GU
04/02/2026
Filed — New Building
Proposed 2 family,3 story with Cellar
Q00478440-P4
02/16/2026
Signed off — New Building
Proposed 2 family,3 story with Cellar
Q00478440-S2
02/16/2026
Signed off — New Building
Proposed 2 family,3 story with Cellar
Q00478440-S4
02/12/2026
Inspection — Pass-Final Curb Cut Non-Directive 14
Pass
View inspection ↗
01/20/2026
Inspection — Fail-Final Curb Cut Non-Directive 14
Fail
View inspection ↗
01/14/2026
Signed off — Alteration
Q01053218-I1
01/12/2026
Permit issued — Curb Cut
Q00478440-S2-CC
12/23/2025
Signed off — Alteration
Q01115225-I1
11/05/2025
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
10/17/2025
Permit issued — Plumbing
Q00478440-S4-PL
09/16/2025
Filed — New Building
Proposed 2 family,3 story with Cellar
Q00478440-P2
09/03/2025
Permit issued — Plumbing
Q00478440-S4-PL
08/21/2025
Permit issued — Plumbing
Q00478440-S4-PL
02/27/2025
Violation issued (ECB, closed)
Construction
02/27/2025
Violation issued (ECB, closed)
Unknown
02/06/2025
Permit issued — Foundation
Q00478440-I1-ST
02/06/2025
Permit issued — Mechanical Systems
Q00478440-I1-FO
02/06/2025
Inspection — Pass-Final House Connection
Pass
View inspection ↗
01/23/2025
Permit issued — Construction Fence
Q01053218-I1-FN
01/23/2025
Permit issued — Foundation
Q00478440-I1-GC
01/02/2025
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
01/02/2025
Inspection — Certified Storm Drainage-ST-Piping-Underground
Certified
View inspection ↗
01/02/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
01/02/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
12/04/2024
Filed — New Building
Proposed 2 family,3 story with Cellar
Q00478440-P1
10/29/2024
Permit issued — Foundation
Q00478440-I1-MS
09/26/2024
Permit issued — Plumbing
Q00478440-S4-PL
09/25/2024
Permit issued — Solar
Q01115225-I1-SL
09/23/2024
Filed — Alteration
Q01115225-I1
Latest 60 of 75 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWCurb CutSigned-offPlanet Construction & de*01/12/2026
DOB NOWPlumbingSigned-offDW Plumbing10/17/2025
DOB NOWPlumbingSigned-offDW Plumbing09/03/2025
DOB NOWPlumbingSigned-offDW Plumbing08/21/2025
DOB NOWFoundationSigned-offGreen JJ Management02/06/2025
DOB NOWMechanical SystemsSigned-offGreen JJ Management02/06/2025
DOB NOWConstruction FenceSigned-offGreen JJ Management01/23/2025
DOB NOWFoundationPermit IssuedGreen JJ Management01/23/2025
DOB NOWFoundationSigned-offGreen JJ Management10/29/2024
DOB NOWPlumbingSigned-offDW Plumbing09/26/2024
DOB NOWSolarSigned-offAccord Power09/25/2024
DOB NOWConstruction FenceSigned-offGreen JJ Management06/06/2024
DOB NOWMechanical SystemsPermit IssuedGreen JJ Management05/20/2024
DOB NOWStructuralPermit IssuedYafe Meod11/09/2023
1 project · most recent 04/02/2026
Air Conditioning Systems Heating and Air Conditioning Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
04/02/2026Signed-offPlanet Construction & de*Air Conditioning Systems, Heating and Air Conditioning Systems, Ventilation Systems
Cooling
Midea CONDENSER 1: DLCMHBH48EAK (HEATING AND COOLING) 2 tons · Condensing Unit ×2
CONDENSER 2: DLCMHBH48EAK (HEATING AND COOLING) 2 tons · Condensing Unit ×2
LOCATION OSP - CONDENSER 3: DLCMRBH18BAK (HEATING AND COOLING) 40,000 BTU · Furnace ×2
LOCATION OSP - CONDENSER 4: DLCSRBH09AAK (HEATING AND COOLING) 68,000 BTU · Furnace ×2
Rheem R92T0701317MSA 68,000 BTU · Furnace ×1
R92TA0401317MSA 40,000 BTU · Furnace ×1
RA1324AJ1NA 2 tons · Condensing Unit ×1
RA1330AJ1NA 2 tons · Condensing Unit ×1
Ventilation
Greenheck Sp-B80 75 CFM · Exhaust Fan ×18
SP-A190 150 CFM · Kitchen Exhaust ×6
Heat / Cool
Midea CONDENSER 1 MODEL: DLCMHBH48EAK, CONDENSER 2 MODEL: DLCMHBH48EAK 48,000 BTU · Heat Pump Outdoor ×2
MODEL: DLCMRBH18BAK 18,000 BTU · Heat Pump Outdoor ×1
MODEL: DLCSRBH09AAK 9,000 BTU · Heat Pump Outdoor ×1
1 project · most recent 04/02/2026
Gas Storm Water/Sanitary
FiledStatusContractorScope
04/02/2026Signed-offTri State Plumbing & HeatingGas, Storm, Water/Sanitary
2 projects · most recent 09/24/2024
General Wiring
FiledStatusContractorScope
09/24/2024CompletePower Surge Electric—
09/10/2024CompleteKwong Ming ElectricGeneral Wiring
1 project · most recent 04/02/2026
Steel Concrete Wood
FiledStatusContractorScope
04/02/2026Signed-offPlanet Construction & de*Steel, Concrete, Wood
▾Field Inspections (DOB CAP) — 8
DateTypeResultReport
02/12/2026Pass-Final Curb Cut Non-Directive 14PassView ↗
01/20/2026Fail-Final Curb Cut Non-Directive 14FailView ↗
11/05/2025Pass-Final CND-Occupancy InspectionPassView ↗
02/06/2025Pass-Final House ConnectionPassView ↗
01/02/2025Certified Gas-Gas-Piping-RoughingCertifiedView ↗
01/02/2025Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
01/02/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
01/02/2025Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 114
DateRequirementInspectorRole
04/09/2026Permanent certificateXIONGCAI GUenergy_progress
04/09/2026Air barrier - visual inspectionXIONGCAI GUenergy_progress
04/09/2026Fenestration and door U-factor and product ratingsXIONGCAI GUenergy_progress
04/09/2026Electric vehicle service equipment requirementsXIONGCAI GUenergy_progress
04/09/2026Protection of exposed foundation insulationXIONGCAI GUenergy_progress
04/09/2026Ventilation and air distribution systemXIONGCAI GUenergy_progress
04/09/2026Maintenance informationXIONGCAI GUenergy_progress
04/09/2026Air barrier — testing XIONGCAI GUenergy_progress
04/09/2026Fenestration areasXIONGCAI GUenergy_progress
04/09/2026HVAC-R and service water piping design and insulationXIONGCAI GUenergy_progress
04/09/2026MasonryXIONGCAI GUspecial
04/09/2026Wood – Prefabricated I-JoistsXIONGCAI GUspecial
04/09/2026Mechanical SystemsXIONGCAI GUspecial
04/09/2026Exterior Insulation and Finish Systems (EIFS)XIONGCAI GUspecial
04/09/2026Private On-Site Storm Water Disposal Systems-, and Detention Facilities, InstallationXIONGCAI GUspecial
04/09/2026Concrete - Cast-In-PlaceXIONGCAI GUspecial
04/09/2026Structural Steel - WeldingXIONGCAI GUspecial
04/09/2026Structural Cold-Formed SteelXIONGCAI GUspecial
04/09/2026Subgrade InspectionsXIONGCAI GUspecial
04/09/2026Structural Steel - DetailsXIONGCAI GUspecial
04/09/2026Fire-Resistant Penetrations and JointsXIONGCAI GUspecial
04/09/2026Subsurface Investigations (Borings/Test Pits)ROBERT DYKSTRAspecial
04/09/2026Structural Wood FrameXIONGCAI GUprogress
04/09/2026FinalDENIS PORTAEVprogress
04/09/2026Fire-Resistance Rated ConstructionXIONGCAI GUprogress
Latest 25 of 114.
▾Documents — 84 on file (BIS + DOB NOW)
▸Plans & Drawings9
▸DOB NOWPlans/Sketch9
08/22/2026Q01053218-I1Request digital key ↗
08/21/2026Q01115225-I1Request digital key ↗
08/21/2026Q00478440-P4Request digital key ↗
Showing 3 of 9 on file for this type
▸Zoning, Tax Lot & Property Records10
▸DOB NOWZD1: DOB Zoning Diagram4
08/21/2026Q00478440-P4Open ↗
08/13/2026Q00478440-I1Open ↗
08/13/2026Q00478440-P2Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWZoning Exhibit form (1-5)4
08/21/2026Q00478440-P4Open ↗
08/13/2026Q00478440-P3Open ↗
08/13/2026Q00478440-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWHouse Number Verification: TOPO Stamp2
08/21/2026Q00478440-P4Open ↗
08/13/2026Q00478440-I1Open ↗
▸Seals & Professional Certifications37
▸DOB NOWProgress Inspector Seal & Signature20
09/23/2026Q01115225-I1Open ↗
09/23/2026Q01115225-I1Open ↗
09/23/2026Q01115225-I1Open ↗
Showing 3 of 20 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature9
08/21/2026Q00478440-P4Open ↗
08/21/2026Q00478440-I1Open ↗
08/13/2026Q01115225-I1Open ↗
Showing 3 of 9 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature8
09/23/2026Q01115225-I1Open ↗
09/23/2026Q01115225-I1Open ↗
08/31/2026Q00478440-I1Open ↗
Showing 3 of 8 on file for this type
▸Trade Schedules & Equipment3
▸DOB NOWDEP: Sewer Certification (Sanitary/Storm)3
08/13/2026Q00478440-P3Open ↗
08/13/2026Q00478440-P2Open ↗
08/13/2026Q00478440-I1Open ↗
▸Safety & Tenant Protection7
▸DOB NOWStreet Tree Checklist4
08/21/2026Q00478440-I1Open ↗
08/21/2026Q00478440-P4Open ↗
08/13/2026Q00478440-P3Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWParks Department Acknowledgment Letter for Street Trees Plan1
08/13/2026Q00478440-I1Open ↗
▸DOB NOWStreet Tree Sign Off1
08/13/2026Q00478440-I1Open ↗
▸DOB NOWStreet Trees Site Plan1
08/13/2026Q00478440-I1Open ↗
▸Energy Compliance2
▸DOB NOWPreliminary Commissioning Report Certification1
08/13/2026Q00478440-S4Open ↗
▸DOB NOWEN2: As Built Energy Analysis.1
08/13/2026Q00478440-I1Open ↗
▸Inspections & Test Reports6
▸DOB NOWSOIL REPORT4
08/21/2026Q00478440-P4Open ↗
08/13/2026Q00478440-P2Open ↗
08/13/2026Q00478440-P3Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWTR4 Test Report and Plot Diagram1
08/13/2026Q00478440-I1Open ↗
▸DOB NOWTR4 Plot Diagram1
08/13/2026Q00478440-I1Open ↗
▸Approvals, Objections & Sign-offs1
▸DOB NOWUtility Company Final Acceptance Letter1
08/13/2026Q01115225-I1Open ↗
▸Other Documents9
▸DOB NOWSite Survey: Initial4
08/21/2026Q00478440-P4Open ↗
08/13/2026Q00478440-I1Open ↗
08/13/2026Q00478440-P2Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone4
08/21/2026Q00478440-P4Open ↗
08/13/2026Q00478440-P2Open ↗
08/13/2026Q00478440-P3Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWFinal Survey1
08/13/2026Q00478440-I1Open ↗