| Owner | Filings | Most Recent |
|---|---|---|
| Vistah Group | 17 | 04/09/2026 |
| Kamali Organization | 15 | 07/08/2026 |
| Firm | Filings | Most Recent |
|---|---|---|
| Arnold Montag Architect AM/PM Desi | 8 | 09/16/2025 |
| Synergic Design Architects | 1 | 09/24/2024 |
| Representative | Filings | Most Recent |
|---|---|---|
| AM PM Design Consulting P | 2 | 03/21/2026 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| Green JJ Management | General Contractor | 5 | 07/08/2026 |
| Green JJ Management | Scaffold | 4 | 04/09/2026 |
| Yafe Meod | General Contractor | 3 | 03/21/2026 |
| Tri State Plumbing & Heating | Plumbing | 3 | 07/08/2026 |
| Accord Power | General Contractor | 1 | 04/09/2026 |
| Planet Construction & de* | General Contractor | 1 | 04/09/2026 |
| Agency | License # | Filings | Most Recent |
|---|---|---|---|
| G Engineering | 7778 | 3 | 09/16/2025 |
| Synergic Design | 8561 | 1 | 09/24/2024 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| DOB NOW | Curb Cut | Signed-off | Planet Construction & de* | 01/12/2026 |
| DOB NOW | Plumbing | Signed-off | DW Plumbing | 10/01/2025 |
| DOB NOW | Plumbing | Signed-off | DW Plumbing | 09/05/2025 |
| DOB NOW | Mechanical Systems | Signed-off | Green JJ Management | 02/06/2025 |
| DOB NOW | Foundation | Signed-off | Green JJ Management | 02/06/2025 |
| DOB NOW | General Construction | Permit Issued | Green JJ Management | 01/23/2025 |
| DOB NOW | Construction Fence | Signed-off | Green JJ Management | 01/23/2025 |
| DOB NOW | Mechanical Systems | Signed-off | Green JJ Management | 10/29/2024 |
| DOB NOW | Plumbing | Signed-off | DW Plumbing | 09/25/2024 |
| DOB NOW | Solar | Signed-off | Accord Power | 09/25/2024 |
| DOB NOW | Construction Fence | Signed-off | Green JJ Management | 06/06/2024 |
| DOB NOW | General Construction | Permit Issued | Green JJ Management | 05/20/2024 |
| DOB NOW | Structural | Permit Issued | Yafe Meod | 11/13/2023 |
| Filed | Status | Contractor | Scope | Make / Model / Capacity |
|---|---|---|---|---|
| 09/16/2025 | Signed-off | Planet Construction & de* | Air Conditioning Systems, Ventilation Systems | Cooling Midea LOCATION OSP CONDENSER 1: MODEL: DLCMHBH48EAK (HEATING AND COOLNG) 40,000 BTU · Furnace ×2 CONDENSER 2: MODEL: DLCMHBH48EAK (HEATING AND COOLNG) 2 tons · Condensing Unit ×2 CONDENSER 3: DLCMRBH18BAK (HEATING AND COOLING) 2 tons · Condensing Unit ×2 LOCATION OSP CONDENSER 1: MODEL: DLCMHBH48EAK (HEATING AND COOLING) 40,000 BTU · Furnace ×2 Rheem R92TA0401317MSA 40,000 BTU · Furnace ×2 RA1324AJ1NA 2 tons · Condensing Unit ×1 RA1330AJ1NA 2 tons · Condensing Unit ×1 Ventilation Greenheck Sp-B80 75 CFM · Exhaust Fan ×18 |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 09/16/2025 | Signed-off | Tri State Plumbing & Heating | Gas, Storm, Water/Sanitary |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 09/25/2024 | Complete | Power Surge Electric | — |
| 09/10/2024 | Complete | Kwong Ming Electric | General Wiring |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 09/16/2025 | Signed-off | Planet Construction & de* | Concrete, Wood |
| Date | Type | Result | Report |
|---|---|---|---|
| 02/12/2026 | Pass-Final Curb Cut Non-Directive 14 | Pass | View ↗ |
| 01/20/2026 | Fail-Final Curb Cut Non-Directive 14 | Fail | View ↗ |
| 10/30/2025 | Pass-Final CND-Occupancy Inspection | Pass | View ↗ |
| 03/18/2025 | Pass-Final House Connection | Pass | View ↗ |
| 12/24/2024 | Certified Gas-Gas-Piping-Roughing | Certified | View ↗ |
| 12/24/2024 | Certified Storm Drainage-ST-Piping-Underground | Certified | View ↗ |
| 12/24/2024 | Certified Water and Sanitary-WS-Sanitary Piping-Roughing | Certified | View ↗ |
| 12/24/2024 | Certified Water and Sanitary-WS-Sanitary Piping-Underground | Certified | View ↗ |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 07/22/2025 | Maintenance information | Arnold Montag | energy_progress |
| 07/22/2025 | Air barrier - visual inspection | XIONGCAI GU | energy_progress |
| 07/22/2025 | Metering | Arnold Montag | energy_progress |
| 07/22/2025 | Fenestration areas | XIONGCAI GU | energy_progress |
| 07/22/2025 | Ventilation and air distribution system | Arnold Montag | energy_progress |
| 07/22/2025 | Permanent certificate | Arnold Montag | energy_progress |
| 07/22/2025 | Concrete - Cast-In-Place | XIONGCAI GU | special |
| 07/22/2025 | Fire-Resistant Penetrations and Joints | XIONGCAI GU | special |
| 07/22/2025 | Masonry | XIONGCAI GU | special |
| 07/22/2025 | Mechanical Systems | XIONGCAI GU | special |
| 07/22/2025 | Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation | XIONGCAI GU | special |
| 07/22/2025 | Structural Cold-Formed Steel | XIONGCAI GU | special |
| 07/22/2025 | Subgrade Inspections | XIONGCAI GU | special |
| 07/22/2025 | Subsurface Investigations (Borings/Test Pits) | ROBERT DYKSTRA | special |
| 07/22/2025 | Wood – Prefabricated I-Joists | XIONGCAI GU | special |
| 07/22/2025 | Energy Code Compliance Inspections | XIONGCAI GU | progress |
| 07/22/2025 | Final | XIONGCAI GU | progress |
| 07/22/2025 | Fire-Resistance Rated Construction | XIONGCAI GU | progress |
| 07/22/2025 | Footing and Foundation | XIONGCAI GU | progress |
| 07/22/2025 | Structural Wood Frame | XIONGCAI GU | progress |
| 07/22/2025 | HVAC-R and service water heating equipment | XIONGCAI GU | energy_progress |
| 07/22/2025 | Fenestration air leakage | XIONGCAI GU | energy_progress |
| 07/22/2025 | Electric vehicle service equipment requirements | XIONGCAI GU | energy_progress |
| 07/22/2025 | Insulation placement and R values | XIONGCAI GU | energy_progress |
| 07/22/2025 | HVAC-R and service water heating system controls | XIONGCAI GU | energy_progress |