← Back
Two family converted from one family
150-29 121 AVENUE
QUEENS · Baisley Park · BIN 4265217
💬 Discuss this project
1935Year Built
2Stories
B3Building Class
R3XZoning
2,170 sfGross Floor Area
2Units
Two family converted from one family · 4,000 sf lot · 0.54 FAR built · Flood zone X
Locations of Work
ArchitectureElectrical
Roof1p · 1 filing · 7 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
TOM PETERSEN ARCHITECT, LLC107/25/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
SUNCO CAPITAL203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
SUNCO CAPITAL LLCGeneral Contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
THOMAS PETERSEN ARCHITECT7854107/25/2024
Building Lifecycle
All (10)Filed (1)Permit Issued (1)Signed Off (1)Objection (2)Special Inspection (5)
10/31/2024
Signed off — Alteration
INSTALLATION OF SOLAR PANELS ON ROOF. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
Q01083680-I1
09/17/2024
Permit issued — Solar
Q01083680-I1-SL
09/05/2024
Objection resolved — Addressed
07/26/2024
Objection raised — Structural
07/25/2024
Filed — Alteration
INSTALLATION OF SOLAR PANELS ON ROOF. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
Q01083680-I1
07/22/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
TOM PETERSEN
07/22/2024
Special inspection requirement — Structural Stability – Alterations of existing buildings
TOM PETERSEN
07/22/2024
Special inspection requirement — Energy Code Compliance Inspections
TOM PETERSEN
07/22/2024
Special inspection requirement — Final
TOM PETERSEN
07/22/2024
Special inspection requirement — Air barrier - visual inspection
TOM PETERSEN
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarSigned-offSUNCO CAPITAL LLC09/17/2024
BISEQISSUEDMILLENNIUM BLDG CONSTRUCTION COR03/14/2005
BIS—ISSUEDMILLENNIUM BLDG CONSTRUCTION COR03/14/2005
BISPLISSUEDMASTERS MECHANICAL PLUMBING & HE10/15/2004
BIS—ISSUEDCHOO CONSTRUCTION CORP.05/06/2004
BISEQISSUEDCHOO CONSTRUCTION CORP.05/06/2004
1 project · most recent 07/26/2024
FiledStatusContractorScope
07/26/2024CompleteBERGER QUALITY ELEC'L CON—
▾Special Inspection Requirements (DOB NOW) — 5
DateRequirementInspectorRole
07/22/2024Fire-Resistant Penetrations and JointsTOM PETERSENspecial
07/22/2024Structural Stability – Alterations of existing buildingsTOM PETERSENspecial
07/22/2024Energy Code Compliance InspectionsTOM PETERSENprogress
07/22/2024FinalTOM PETERSENprogress
07/22/2024Air barrier - visual inspectionTOM PETERSENenergy_progress
▾Documents — 7 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/21/2026Q01083680-I1Request digital key ↗
▸Seals & Professional Certifications4
▸DOB NOWProgress Inspector Seal & Signature2
08/27/2026Q01083680-I1Open ↗
08/27/2026Q01083680-I1Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/13/2026Q01083680-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/27/2026Q01083680-I1Open ↗
▸Environmental & Asbestos1
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/13/2026Q01083680-I1Open ↗
▸Approvals, Objections & Sign-offs1
▸DOB NOWUtility Company Final Acceptance Letter1
08/13/2026Q01083680-I1Open ↗