← Back
Two stories - detached, small or mid-size
150-51 87 AVENUE
QUEENS · BIN 4208210
💬 Discuss this project
1920Year Built
2.5Stories
A1Building Class
R3XZoning
2,935 sfGross Floor Area
1Units
Rent Stabilized0 Open ViolationsFDNY Report ↗
Two stories - detached, small or mid-size · 4,000 sf lot · 0.73 FAR built · Flood zone X
Locations of Work
Architecture
Floor 11p · 1 filing · 10 docs
Cellar2p · 2 filings · 13 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
11/05/2018$805K—Private party → Private party$274/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
NY BUILDING ASSOCIATES INC208/09/2022
ALBERTO ROMAN111/22/2021
JAMIL COPPIN ARCHITECT PC108/04/2020
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
AM EXPEDITING DRAFTING DESIGN403/21/2026
ARCHVISION DESIGN STUDIO103/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
AM EXPEDITING DRAFTING &General Contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
NKM ENGINEERING PLLC6244208/09/2022
JAMIL COPPIN ARCHITECT PC3266108/04/2020
Building Lifecycle
All (41)Filed (4)Permit Issued (1)Signed Off (1)Violation (9)Inspection (1)Objection (15)Special Inspection (10)
11/25/2025
Violation issued (HPD, closed)
I
04/01/2024
Violation issued (HPD, closed)
I
03/27/2024
Violation issued (HPD, closed)
C
03/27/2024
Violation issued (HPD, closed)
A
03/27/2024
Violation issued (HPD, closed)
B
03/27/2024
Violation issued (HPD, closed)
C
09/14/2022
Signed off — Alteration
BUILD NEW CONCRETE REAR CELLAR ESTAIR, ENTRANCE AND WINDOW, INSTALL NON LOAD BEARING PARTITIONS IN CELLAR AND FIRST FLOOR AND REMOVE MASONRY FENCE TO BUILD NEW MASONRY FENCE ON TOP OF EXISTING REATINING WALL. NO CHANGE IN USE, OCCUPANCY OR EGRESS.
Q00662358-I1
09/13/2022
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
08/31/2022
Objection resolved — Addressed
08/31/2022
Objection resolved — Addressed
08/31/2022
Objection resolved — Addressed
08/20/2022
Objection raised — Zoning
08/20/2022
Objection raised — Fire_Protection
08/20/2022
Objection raised — Zoning
08/15/2022
Objection raised — Other
08/15/2022
Objection resolved — Addressed
08/09/2022
Filed — Alteration
BUILD NEW CONCRETE REAR CELLAR ESTAIR, ENTRANCE AND WINDOW, INSTALL NON LOAD BEARING PARTITIONS IN CELLAR AND FIRST FLOOR AND REMOVE MASONRY FENCE TO BUILD NEW MASONRY FENCE ON TOP OF EXISTING REATINING WALL. NO CHANGE IN USE, OCCUPANCY OR EGRESS.
Q00662358-P1
08/08/2022
Special inspection requirement — Preliminary
NARESH MAHANGU
08/08/2022
Special inspection requirement — Concrete - Cast-In-Place
NARESH MAHANGU
08/08/2022
Special inspection requirement — Structural Stability – Alterations of existing buildings
NARESH MAHANGU
08/08/2022
Special inspection requirement — Energy Code Compliance Inspections
NARESH MAHANGU
08/08/2022
Special inspection requirement — Fire-Resistance Rated Construction
NARESH MAHANGU
02/16/2022
Permit issued — General Construction
Q00662358-I1-GC
01/14/2022
Filed — Alteration
BUILD NEW CONCRETE REAR CELLAR ESTAIR, ENTRANCE AND WINDOW, INSTALL NON LOAD BEARING PARTITIONS IN CELLAR AND FIRST FLOOR AND REMOVE MASONRY FENCE TO BUILD NEW MASONRY FENCE ON TOP OF EXISTING REATINING WALL. NO CHANGE IN USE, OCCUPANCY OR EGRESS.
Q00662358-I1
11/26/2021
Objection raised — Scope
11/26/2021
Objection resolved — Addressed
11/26/2021
Objection raised — Scope
11/26/2021
Objection resolved — Addressed
11/26/2021
Objection raised — Zoning
11/26/2021
Objection raised — Scope
11/26/2021
Objection raised — Structural
11/22/2021
Filed — Alteration
Q00635077-I1
11/21/2021
Special inspection requirement — Masonry
11/21/2021
Special inspection requirement — Concrete - Cast-In-Place
11/21/2021
Special inspection requirement — Fire-Resistant Penetrations and Joints
11/21/2021
Special inspection requirement — Structural Stability – Alterations of existing buildings
11/21/2021
Special inspection requirement — Fire-Resistance Rated Construction
10/27/2021
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
07/28/2021
Violation issued (ECB, closed)
Construction
07/28/2021
Violation issued (ECB, closed)
Construction
08/04/2020
Filed — Alteration
Q00377388-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionSigned-offAM EXPEDITING DRAFTING &02/16/2022
1 project · most recent 02/14/2022
FiledStatusContractorScope
02/14/2022CompleteAUJLA ELECTRIC CORP—
1 project · most recent 11/22/2021
FiledStatusContractorScope
11/22/2021——1 scope_items
▾Field Inspections (DOB CAP) — 1
DateTypeResultReport
09/13/2022Pass-Final General Construction Non-Directive 14PassView ↗
▾Special Inspection Requirements (DOB NOW) — 10
DateRequirementInspectorRole
08/08/2022PreliminaryNARESH MAHANGUprogress
08/08/2022Concrete - Cast-In-PlaceNARESH MAHANGUspecial
08/08/2022Structural Stability – Alterations of existing buildingsNARESH MAHANGUspecial
08/08/2022Energy Code Compliance InspectionsNARESH MAHANGUprogress
08/08/2022Fire-Resistance Rated ConstructionNARESH MAHANGUprogress
11/21/2021Masonry—special
11/21/2021Concrete - Cast-In-Place—special
11/21/2021Fire-Resistant Penetrations and Joints—special
11/21/2021Structural Stability – Alterations of existing buildings—special
11/21/2021Fire-Resistance Rated Construction—progress
▾Documents — 46 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch3
08/26/2026Q00662358-I1Request digital key ↗
08/15/2026Q00635077-I1Request digital key ↗
08/15/2026Q00662358-P1Request digital key ↗
▸DOB NOWPlans/Sketch - Plumbing1
08/28/2026Q00377388-I1Request digital key ↗
▸Applications & Permits5
▸BISPLAN / WORK APPROVAL APPLICATION5
08/10/2020421944203Open ↗
06/25/2020421944203Open ↗
06/16/2020421944203Open ↗
Showing 3 of 5 on file for this type
▸Seals & Professional Certifications9
▸DOB NOWDPL-1: Design Professional Seal & Signature4
08/28/2026Q00377388-I1Open ↗
08/26/2026Q00662358-I1Open ↗
08/26/2026Q00662358-P1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWProgress Inspector Seal & Signature2
08/28/2026Q00662358-P1Open ↗
08/23/2026Q00662358-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
08/28/2026Q00662358-P1Open ↗
08/23/2026Q00662358-I1Open ↗
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION1
03/12/2020421944203Open ↗
▸Safety & Tenant Protection1
▸BISSTREET TREE CHECKLIST1
03/12/2020421944203Open ↗
▸Environmental & Asbestos6
▸DOB NOWDEP ACP-5: Asbestos Assessment Report5
08/28/2026Q00377388-I1Open ↗
08/26/2026Q00662358-I1Open ↗
08/15/2026Q00662358-P1Open ↗
Showing 3 of 5 on file for this type
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
06/29/2020421944203Open ↗
▸Energy Compliance2
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY1
09/09/2020421944203Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS1
03/12/2020421944203Open ↗
▸Inspections & Test Reports2
▸BISTECHNICAL REPORT: RESPONSIBILITY1
09/09/2020421944203Open ↗
▸BISSOIL REPORT1
06/29/2020421944203Open ↗
▸Approvals, Objections & Sign-offs9
▸BISSCHEDULE A - OCCUPANCY / USE5
06/25/2020421944203Open ↗
04/13/2020421944203Open ↗
04/10/2020421944203Open ↗
Showing 3 of 5 on file for this type
▸BISLETTERS - SUPPORTING DOCUMENTATION3
06/24/2020421944203Open ↗
06/24/2020421944203Open ↗
04/01/2020421944203Open ↗
▸BISCONSTRUCTION CODE DETERMINATION1
06/24/2020421944203Open ↗
▸Cost, Insurance & Ownership3
▸BISCOST AFFIDAVIT3
04/13/2020421944203Open ↗
04/01/2020421944203Open ↗
03/12/2020421944203Open ↗
▸Filing & Intake Forms4
▸BISADDITIONAL INFORMATION2
09/09/2020421944203Open ↗
06/24/2020421944203Open ↗
▸BISBOROUGH INTAKE FORM1
04/13/2020421944203Open ↗
▸BISEFILING COVER SHEET1
03/12/2020421944203Open ↗
▸Other Documents1
▸BISPLOT DIAGRAM1
03/12/2020421944203Open ↗