| Owner | Filings | Most Recent |
|---|---|---|
| CHURCH OF ST CLARE | 12 | 04/09/2026 |
| ST CLARE CHURCH | 2 | 03/21/2026 |
| ST CLARES R C CHURCH | 4 | 03/21/2026 |
| Firm | Filings | Most Recent |
|---|---|---|
| THINK DESIGN ARCHITECTURE | 1 | 01/28/2026 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| MACKENZIE, DOUGLAS | Electrical | 1 | 03/21/2026 |
| RODRIGUEZ, GIANFRANCO | Electrical | 1 | 03/21/2026 |
| EDDY'S GENERAL CONSTRUCT | General Contractor | 1 | 04/09/2026 |
| Agency | License # | Filings | Most Recent |
|---|---|---|---|
| THINK DESIGN ARCHITECTURA | 683 | 1 | 01/28/2026 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| DOB NOW | Mechanical Systems | Permit Issued | EDDY'S GENERAL CONSTRUCT | 03/25/2026 |
| BIS | OT | ISSUED | WINICK PRODUCTIONS, LLC | 11/10/2020 |
| BIS | PL | ISSUED | CAPITAL CONTR P&H CORP | 09/24/2019 |
| BIS | OT | ISSUED | CES DANBURY SOLAR LLC | 02/12/2019 |
| BIS | PL | ISSUED | CAPITAL CONTR P&H CORP | 08/14/2018 |
| BIS | SP | ISSUED | WALTER J. GRANDE P&H INC. | 03/02/2018 |
| BIS | PL | ISSUED | KCM PLUMBING & HEATING CO | 01/24/2018 |
| BIS | OT | ISSUED | EMPIRE STATE CONTRACTING | 07/03/2017 |
| BIS | EQ | ISSUED | EMPIRE STATE CONTRACTING | 07/03/2017 |
| BIS | SP | ISSUED | CAPITAL CONTR P & H CORP | 06/27/2001 |
| BIS | PL | ISSUED | CAPITAL CONTR P&H CORP | 06/19/2001 |
| BIS | PL | ISSUED | SCARAN PLUMBING INC | 11/17/1995 |
| BIS | MH | ISSUED | SCARAN OIL SERVICE | 11/14/1995 |
| BIS | SP | ISSUED | BEST SPRINKLER LTD | 08/09/1995 |
| Filed | Status | Contractor | Scope | Make / Model / Capacity |
|---|---|---|---|---|
| 01/28/2026 | Permit Issued | EDDY'S GENERAL CONSTRUCT | Heating and Air Conditioning Systems | Heat / Cool Carrier 48FEFM16A3A5A0A0A0 180,000 BTU · Rooftop Unit ×4 25SCA460N0030103 48,000 BTU · Condensing Unit ×1 |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 10/11/2018 | Complete | STAR ELEC'L CONTRACTORS C | — |
| 10/03/2018 | Complete | BRANDL ELECTRIC INC. | — |
| 01/16/2018 | Complete | FICHERA ELECTRIC, INC | General Wiring |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 01/08/2026 | Mechanical Systems | Frank Martarella III | special |
| 01/08/2026 | Energy Code Compliance Inspections | Frank Martarella III | progress |
| 01/08/2026 | Final | Frank Martarella III | progress |
| 01/08/2026 | Maintenance information | Frank Martarella III | energy_progress |
| 01/08/2026 | HVAC-R and service water heating system controls | Frank Martarella III | energy_progress |
| 01/08/2026 | HVAC-R and service water heating equipment | Frank Martarella III | energy_progress |
| 01/08/2026 | HVAC-R and service water piping design and insulation | Frank Martarella III | energy_progress |
| 01/08/2026 | Permanent certificate | Frank Martarella III | energy_progress |
| 01/08/2026 | Shutoff dampers | Frank Martarella III | energy_progress |