← Back
Two family brick
150 WEST 11 STREET
MANHATTAN · BIN 1010533
💬 Discuss this project
1836Year Built
3Stories
B1Building Class
C1-6Zoning
2,880 sfGross Floor Area
2Units
0 Open Violations
Two family brick · Owner of record: LIDA'S RANCH LLC · 931 sf lot · 3.09 FAR built · Flood zone X
Locations of Work
Mechanical
Roof1p · 1 filing · 9 docs
Cellar1p · 1 filing · 9 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
06/30/2022$8.9M—Private party → LIDA'S RANCH LLC$3,090/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
HIGH LINE ENGINEERING PC104/26/2023
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
JOSELITO MENDOZAElectrical103/21/2026
WIESLAW MAKSIMElectrical103/21/2026
Z S NY IMPROVEMENT CORPGeneral Contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
HIGH LINE ENGINEERING PC2920104/26/2023
Building Lifecycle
All (12)Filed (1)Permit Issued (1)Signed Off (1)Violation (3)Special Inspection (6)
02/17/2026
Signed off — Alteration
Replacing existing AC units with (4) VRF Heat pump split systems. Outdoor condensing units are being placed on existing steel dunnage.
M00862469-I1
05/03/2023
Permit issued — Mechanical Systems
M00862469-I1-MS
04/26/2023
Filed — Alteration
Replacing existing AC units with (4) VRF Heat pump split systems. Outdoor condensing units are being placed on existing steel dunnage.
M00862469-I1
04/20/2023
Special inspection requirement — Mechanical Systems
Ruslan Nagorny
04/20/2023
Special inspection requirement — Final
Ruslan Nagorny
04/20/2023
Special inspection requirement — HVAC-R and service water heating equipment
Ruslan Nagorny
04/20/2023
Special inspection requirement — HVAC-R and service water heating system controls
Ruslan Nagorny
04/20/2023
Special inspection requirement — Maintenance information
Ruslan Nagorny
04/20/2023
Special inspection requirement — HVAC-R and service water piping design and insulation
Ruslan Nagorny
11/28/2007
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
11/28/2007
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
10/28/2007
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsSigned-offZ S NY IMPROVEMENT CORP05/03/2023
BISOTRE-ISSUEDG B CONSTRUCTION LLC04/25/2005
BISPLISSUEDPP COUSIN INC08/10/2004
BISOTISSUEDG B CONSTRUCTION LLC01/30/2004
BISEQISSUEDROCKLEDGE SCAFFOLD CORP04/05/2003
BISEQISSUEDROCKLEDGE SCAFFOLD CORP03/28/2003
BISEQISSUEDROCKLEDGE SCAFFOLD CORP06/20/2002
BISEQISSUEDROCKLEDGE SCAFFOLD CORP06/20/2002
3 projects · most recent 04/24/2026
General Wiring
FiledStatusContractorScope
04/24/2026Permit IssuedEMPIRE LIC ELECL CONTRSGeneral Wiring
05/30/2023CancelledKOBRYN ELEC'L SERVICES INGeneral Wiring
12/22/2022CompleteDENMAR ELECTRIC CORPGeneral Wiring
▾Special Inspection Requirements (DOB NOW) — 6
DateRequirementInspectorRole
04/20/2023Mechanical SystemsRuslan Nagornyspecial
04/20/2023FinalRuslan Nagornyprogress
04/20/2023HVAC-R and service water heating equipmentRuslan Nagornyenergy_progress
04/20/2023HVAC-R and service water heating system controlsRuslan Nagornyenergy_progress
04/20/2023Maintenance informationRuslan Nagornyenergy_progress
04/20/2023HVAC-R and service water piping design and insulationRuslan Nagornyenergy_progress
▾Documents — 10 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/31/2026M00862469-I1Request digital key ↗
▸Applications & Permits1
▸BISPLAN / WORK APPROVAL APPLICATION1
01/15/2020103121970Open ↗
▸Seals & Professional Certifications7
▸DOB NOWProgress Inspector Seal & Signature5
08/29/2026M00862469-I1Open ↗
08/29/2026M00862469-I1Open ↗
08/29/2026M00862469-I1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/13/2026M00862469-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/29/2026M00862469-I1Open ↗
▸Environmental & Asbestos1
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/13/2026M00862469-I1Open ↗