| Owner | Filings | Most Recent |
|---|---|---|
| BROOKLYN COMMUNITY CHRISTIAN CHURCH | 20 | 07/08/2026 |
| OWNER OF 1506 NECK RD (AK | 1 | 03/22/2026 |
| OWNER OF 1502 NECK RD (AK | 1 | 03/22/2026 |
| BROOKLYNCHINESE CHRISTIAN CHURCH | 1 | 03/21/2026 |
| CHINESE CHRISTAIN CHURCH | 7 | 03/21/2026 |
| Firm | Filings | Most Recent |
|---|---|---|
| HTX BUILDING CONSULTING INC | 5 | 01/05/2026 |
| INDETAIL ARCHITECTURAL AND ENGIN | 6 | 07/24/2024 |
| Representative | Filings | Most Recent |
|---|---|---|
| HTX BUILDING CONSULTING | 11 | 03/21/2026 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| JOHN EVAN CONTRACTING COR | General Contractor | 12 | 07/08/2026 |
| JABBIE INDUSTRIES INCORP* | General Contractor | 1 | 07/08/2026 |
| CATMAN PLUMBING INC | Plumbing | 1 | 07/08/2026 |
| Agency | License # | Filings | Most Recent |
|---|---|---|---|
| NYX ENGINEERING, PLLC | 6118 | 2 | 01/05/2026 |
| NKM ENGINEERING PLLC | 6244 | 7 | 07/22/2024 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| DOB NOW | General Construction | Signed-off | JABBIE INDUSTRIES INCORP* | 12/16/2025 |
| DOB NOW | Mechanical Systems | Signed-off | JOHN EVAN CONTRACTING COR | 09/20/2024 |
| DOB NOW | General Construction | Permit Issued | JOHN EVAN CONTRACTING COR | 03/21/2024 |
| DOB NOW | General Construction | Permit Issued | JOHN EVAN CONTRACTING COR | 03/21/2024 |
| DOB NOW | Earth Work | Signed-off | JOHN EVAN CONTRACTING COR | 03/21/2024 |
| DOB NOW | General Construction | Permit Issued | JOHN EVAN CONTRACTING COR | 02/21/2024 |
| DOB NOW | Plumbing | Signed-off | CATMAN PLUMBING INC | 01/30/2024 |
| DOB NOW | Foundation | Signed-off | JOHN EVAN CONTRACTING COR | 01/05/2024 |
| BIS | — | ISSUED | CHINESE CHRISTIAN CHURCH | 08/19/2020 |
| BIS | OT | ISSUED | SING CONSTRUCTION, INC | 11/21/2019 |
| BIS | EQ | ISSUED | HONGTAI CONSTRUCTION INC | 08/14/2017 |
| BIS | OT | ISSUED | HONGTAI CONSTRUCTION INC | 08/14/2017 |
| BIS | — | ISSUED | FORTUNA DESIGN & CONSTRUCTION | 04/05/2012 |
| BIS | — | ISSUED | CHINESE CHRISTIAN CHURCH | 03/03/2000 |
| BIS | — | ISSUED | MAINLAND PLG HTNG INC | 02/01/2000 |
| BIS | PL | ISSUED | MAINLAND PLG HTNG INC | 02/01/2000 |
| BIS | PL | ISSUED | MAINLAND PLUMBING AND HEATING | 05/02/1995 |
| Filed | Status | Contractor | Scope | Make / Model / Capacity |
|---|---|---|---|---|
| 07/24/2024 | Signed-off | JOHN EVAN CONTRACTING COR | Heating and Air Conditioning Systems | Heat / Cool Mitsubishi Electric MXZ-SM48NAM2 48,000 BTU · Heat Pump Outdoor ×12 |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 07/24/2024 | Signed-off | CATMAN PLUMBING INC | Gas, Water/Sanitary |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 09/02/2024 | Complete | A.C. MORGAN ELECTRIC | General Wiring |
| Date | Type | Result | Report |
|---|---|---|---|
| 03/20/2026 | Pass-Final General Construction Non-Directive 14 | Pass | View ↗ |
| 11/13/2024 | Pass-Final CND-Occupancy Inspection | Pass | View ↗ |
| 10/01/2024 | Certified Remove/Cap - work done in accordance with code | Certified | View ↗ |
| 09/24/2024 | Certified Water and Sanitary-WS-Fixtures-Finish | Certified | View ↗ |
| 09/16/2024 | Pass-Final CND-Occupancy Inspection | Pass | View ↗ |
| 09/05/2024 | Fail-Final CND-Occupancy Inspection | Fail | View ↗ |
| 05/17/2024 | Certified Water and Sanitary-WS-Sanitary Piping-Roughing | Certified | View ↗ |
| 04/15/2024 | Certified Storm Drainage-ST-Piping-Underground | Certified | View ↗ |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 01/21/2026 | Energy Code Compliance Inspections | Xiao Huang | progress |
| 01/21/2026 | Fire-Resistant Penetrations and Joints | Xiao Huang | special |
| 01/21/2026 | Structural Stability – Alterations of existing buildings | Xiao Huang | special |
| 10/03/2025 | Energy Code Compliance Inspections | — | progress |
| 10/03/2025 | Structural Stability – Alterations of existing buildings | — | special |
| 10/03/2025 | Fire-Resistant Penetrations and Joints | — | special |
| 08/21/2024 | Lighting controls | NARESH MAHANGU | energy_progress |
| 08/21/2024 | Air barrier - visual inspection | NARESH MAHANGU | energy_progress |
| 08/21/2024 | Maintenance information | NARESH MAHANGU | energy_progress |
| 08/21/2024 | Energy Code Compliance Inspections | NARESH MAHANGU | progress |
| 08/21/2024 | Fire-Resistance Rated Construction | NARESH MAHANGU | progress |
| 08/21/2024 | Structural Stability – Alterations of existing buildings | NARESH MAHANGU | special |
| 08/21/2024 | Fire-Resistant Penetrations and Joints | NARESH MAHANGU | special |
| 08/21/2024 | Interior lighting power | NARESH MAHANGU | energy_progress |
| 08/01/2024 | Mechanical Systems | NARESH MAHANGU | special |
| 08/01/2024 | Structural Stability – Alterations of existing buildings | NARESH MAHANGU | special |
| 08/01/2024 | Final | YUNHO LEE | progress |
| 08/01/2024 | Energy Code Compliance Inspections | NARESH MAHANGU | progress |
| 08/01/2024 | HVAC-R and service water piping design and insulation | NARESH MAHANGU | energy_progress |
| 08/01/2024 | HVAC-R and service water heating equipment | NARESH MAHANGU | energy_progress |
| 08/01/2024 | Maintenance information | NARESH MAHANGU | energy_progress |
| 08/01/2024 | HVAC-R and service water heating system controls | NARESH MAHANGU | energy_progress |
| 07/24/2024 | Maintenance information | — | energy_progress |
| 07/24/2024 | HVAC-R and service water piping design and insulation | — | energy_progress |
| 07/24/2024 | HVAC-R and service water heating system controls | — | energy_progress |