← Back
Two family brick
1506 PRESIDENT STREET
BROOKLYN · Crown Heights (South) · BIN 3037836
💬 Discuss this project
1901Year Built
2Stories
B1Building Class
R4Zoning
3,798 sfGross Floor Area
2Units
Two family brick · 2,405 sf lot · 1.58 FAR built · Flood zone X
Locations of Work
ArchitectureElectricalGeneral
Filed — no permit issued9p · 1 filing · 9 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
ADB ASSOCIATES110/27/2021
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
ACV DESIGN LTD3864110/27/2021
Building Lifecycle
All (31)Filed (1)Objection (18)Special Inspection (12)
03/21/2023
Special inspection requirement — Subsurface Investigations (Borings/Test Pits)
Daniel Boss
03/13/2023
Objection raised — Other
03/13/2023
Objection raised — Fire_Protection
03/13/2023
Objection raised — Other
03/13/2023
Objection raised — Other
03/13/2023
Objection resolved — Addressed
05/24/2022
Objection raised — Scope
05/24/2022
Objection resolved — Addressed
05/24/2022
Objection raised — Scope
05/24/2022
Objection resolved — Addressed
02/28/2022
Objection raised — Zoning
02/28/2022
Objection resolved — Addressed
02/28/2022
Objection raised — Other
02/28/2022
Objection raised — Scope
02/28/2022
Objection resolved — Addressed
11/01/2021
Objection raised — Zoning
11/01/2021
Objection resolved — Addressed
11/01/2021
Objection raised — Zoning
11/01/2021
Objection resolved — Addressed
10/27/2021
Filed — Alteration
EXISTING 2 STORY BRICK & CELLAR, 2 FAMILY DWELLING. PROPOSED HORIZONTAL FLOOR AREA TRANSFER AT REAR & INTERIOR RENOVATION AS PER PLAN .
B00589039-I1
09/06/2021
Special inspection requirement — Excavations - Sheeting, Shoring, and Bracing
ANTHONY VILLANO
09/06/2021
Special inspection requirement — Fire-Resistant Penetrations and Joints
ANTHONY VILLANO
09/06/2021
Special inspection requirement — Masonry
ANTHONY VILLANO
09/06/2021
Special inspection requirement — Structural Stability – Alterations of existing buildings
ANTHONY VILLANO
09/06/2021
Special inspection requirement — Energy Code Compliance Inspections
ANTHONY VILLANO
09/06/2021
Special inspection requirement — Fenestration air leakage
ANTHONY VILLANO
09/06/2021
Special inspection requirement — Insulation placement and R values
ANTHONY VILLANO
09/06/2021
Special inspection requirement — Fenestration areas
ANTHONY VILLANO
09/06/2021
Special inspection requirement — Interior lighting power
ANTHONY VILLANO
09/06/2021
Special inspection requirement — Concrete - Cast-In-Place
ANTHONY VILLANO
09/06/2021
Special inspection requirement — Fenestration and door U-factor and product ratings
ANTHONY VILLANO
Nothing on file for this building.
Nothing on file for this building.
▾Special Inspection Requirements (DOB NOW) — 12
DateRequirementInspectorRole
03/21/2023Subsurface Investigations (Borings/Test Pits)Daniel Bossspecial
09/06/2021Excavations - Sheeting, Shoring, and BracingANTHONY VILLANOspecial
09/06/2021Fire-Resistant Penetrations and JointsANTHONY VILLANOspecial
09/06/2021MasonryANTHONY VILLANOspecial
09/06/2021Structural Stability – Alterations of existing buildingsANTHONY VILLANOspecial
09/06/2021Energy Code Compliance InspectionsANTHONY VILLANOprogress
09/06/2021Fenestration air leakageANTHONY VILLANOenergy_progress
09/06/2021Insulation placement and R valuesANTHONY VILLANOenergy_progress
09/06/2021Fenestration areasANTHONY VILLANOenergy_progress
09/06/2021Interior lighting powerANTHONY VILLANOenergy_progress
09/06/2021Concrete - Cast-In-PlaceANTHONY VILLANOspecial
09/06/2021Fenestration and door U-factor and product ratingsANTHONY VILLANOenergy_progress
▾Documents — 9 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/14/2026B00589039-I1Request digital key ↗
▸Zoning, Tax Lot & Property Records1
▸DOB NOWZD1: DOB Zoning Diagram1
08/14/2026B00589039-I1Open ↗
▸Seals & Professional Certifications2
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/31/2026B00589039-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/22/2026B00589039-I1Open ↗
▸Environmental & Asbestos1
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/14/2026B00589039-I1Open ↗
▸Inspections & Test Reports2
▸DOB NOWTR4 Test Report and Plot Diagram1
08/14/2026B00589039-I1Open ↗
▸DOB NOWSOIL REPORT1
08/14/2026B00589039-I1Open ↗
▸Other Documents2
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone1
08/14/2026B00589039-I1Open ↗
▸DOB NOWPlot Diagram1
08/14/2026B00589039-I1Open ↗