← Back
Primarily 4 family with 1 store or office
151 4 AVENUE
BROOKLYN · BIN 3019323
💬 Discuss this project
1920Year Built
4Stories
S4Building Class
C4-4DZoning
4,615 sfGross Floor Area
5Units
Rent Stabilized83 Open Violations ▸FDNY Report ↗
Primarily 4 family with 1 store or office · Owner of record: IMPROBABLE PROPERTIES LLC · 1,541 sf lot · 2.99 FAR built · Flood zone X
Locations of Work
ArchitectureMechanicalPlumbingLandscape
Roof1p · 1 filing · 3 docs
Floor 46p · 3 filings · 12 docs
Floor 31p · 1 filing · 3 docs
Floor 23p · 2 filings · 9 docs
Floor 1
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
IMPROBABLE PROPERTIES1407/08/2026
NOOM103/22/2026
348 DOUGLASS ST303/21/2026
RESTAURANT203/21/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
04/14/2022$3.5M—348 DOUGLAS STREET LLC → IMPROBABLE PROPERTIES LLC$769/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
TERRY B FUQUA405/10/2023
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
CODE803/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
MANNY LOPEZ ENTERPRISES CGeneral Contractor207/08/2026
BDS ELECTRIC CORP.Electrical103/22/2026
PLBG P & H INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
BEN FUQUA ARCHITECT PLLC5769405/10/2023
Building Lifecycle
All (80)Filed (4)Permit Issued (3)Violation (60)Inspection (3)Objection (6)Special Inspection (4)
04/30/2026
Violation issued (HPD, open)
A
11/19/2025
Violation issued (HPD, open)
I
11/14/2025
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
06/05/2025
Violation issued (HPD, open)
A
11/27/2024
Violation issued (HPD, open)
I
09/23/2024
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
04/03/2024
Violation issued (HPD, open)
A
11/20/2023
Violation issued (HPD, open)
I
10/11/2023
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
10/11/2023
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
06/30/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
06/30/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
06/20/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
06/20/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
05/31/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
05/17/2023
Permit issued — Plumbing
B00768337-I1-PL
05/10/2023
Filed — Alteration
WATER AND WASTE FOR THREE NEW RESIDENTIAL UNIT CONFIGURATIONS ON TOP THREE FLOORS OF A MULTI-USE BUILDING. CAP AND REMOVAL OF EXISTING GAS APPLIANCES. NO CHANGE IN USE OCCUPANCY OR EGRESS.
B00768337-P1
05/09/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
Terry Fuqua
04/25/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
04/05/2023
Objection raised — Zoning
04/05/2023
Objection resolved — Addressed
04/05/2023
Objection raised — Other
04/05/2023
Objection resolved — Addressed
04/04/2023
Filed — Alteration
GUT RENOVATION OF THE TOP THREE FLOORS OF A MULTI-USE BUILDING TO AFFORD NEW LAYOUTS OF THREE RESIDENTIAL UNITS. NEW MECHANICAL SYSTEMS FOR ALL THREE UNITS. NO CHANGE IN USE, OCCUPANCY, OR EGRESS.
B00768338-I1
03/17/2023
Violation issued (HPD, open)
A
02/03/2023
Permit issued — General Construction
B00768336-I1-GC
12/01/2022
Permit issued — General Construction
B00768336-I1-GC
11/09/2022
Violation issued (HPD, open)
I
09/12/2022
Objection raised — Other
09/12/2022
Objection resolved — Addressed
09/09/2022
Filed — Alteration
WATER AND WASTE FOR THREE NEW RESIDENTIAL UNIT CONFIGURATIONS ON TOP THREE FLOORS OF A MULTI-USE BUILDING. CAP AND REMOVAL OF EXISTING GAS APPLIANCES. NO CHANGE IN USE OCCUPANCY OR EGRESS.
B00768337-I1
09/06/2022
Filed — Alteration
GUT RENOVATION OF THE TOP THREE FLOORS OF A MULTI-USE BUILDING TO AFFORD NEW LAYOUTS OF THREE RESIDENTIAL UNITS. NO CHANGE IN USE, OCCUPANCY, OR EGRESS.
B00768336-I1
08/26/2022
Special inspection requirement — Energy Code Compliance Inspections
Terry Fuqua
07/01/2022
Special inspection requirement — Mechanical Systems
Terry Fuqua
07/01/2022
Special inspection requirement — Final
Terry Fuqua
02/18/2022
Violation issued (HPD, open)
I
02/18/2022
Violation issued (HPD, open)
A
04/05/2021
Violation issued (HPD, open)
A
04/05/2021
Violation issued (HPD, open)
I
11/08/2019
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
10/28/2019
Violation issued (HPD, open)
I
08/20/2019
Violation issued (HPD, open)
A
08/20/2019
Violation issued (HPD, open)
A
08/20/2019
Violation issued (HPD, open)
C
08/20/2019
Violation issued (HPD, open)
A
08/20/2019
Violation issued (HPD, open)
B
05/26/2019
Violation issued (HPD, open)
B
05/26/2019
Violation issued (HPD, closed)
C
05/26/2019
Violation issued (HPD, open)
B
05/26/2019
Violation issued (HPD, open)
C
05/26/2019
Violation issued (HPD, open)
B
05/26/2019
Violation issued (HPD, open)
B
05/26/2019
Violation issued (HPD, open)
C
05/26/2019
Violation issued (HPD, open)
B
05/26/2019
Violation issued (HPD, open)
B
05/26/2019
Violation issued (HPD, open)
B
10/12/2018
Violation issued (HPD, open)
I
02/07/2018
Violation issued (HPD, open)
B
02/07/2018
Violation issued (HPD, open)
B
02/07/2018
Violation issued (HPD, closed)
B
Latest 60 of 80 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offPLBG P & H INC05/17/2023
DOB NOWGeneral ConstructionPermit IssuedMANNY LOPEZ ENTERPRISES C02/03/2023
DOB NOWGeneral ConstructionPermit IssuedMANNY LOPEZ ENTERPRISES C12/01/2022
BISEQISSUEDGREAT WILL CONSTR., INC02/20/2009
BISOTISSUEDGREAT WILL CONSTR., INC02/20/2009
BISFPISSUEDCITYWIDE FIRE SYSTEM03/17/2008
BISPLISSUEDCALA/SACCO MECHINICAL INC12/17/2007
BISMHISSUEDGREAT WILL CONSTRUCTION, INC.11/20/2007
BISEQISSUEDGREAT WILL CONSTRUCTION, INC.11/20/2007
1 project · most recent 04/04/2023
Associated Ducts and Piping Heating and Air Conditioning Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
04/04/2023——Associated Ducts and Piping, Heating and Air Conditioning Systems, Ventilation Systems
Heat / Cool
Mitsubishi Electric MSZ GL-06NA 6,000 BTU · Fan Coil Indoor ×7
MSZ GL-12NA 12,000 BTU · Fan Coil Indoor ×3
MXZ-4C36NA2 36,000 BTU · Condensing Unit ×3
MSZ GL-08NA 8,100 BTU · Fan Coil Indoor ×1
Ventilation
Ducts & Piping
N/A ×1
1 project · most recent 05/10/2023
Gas Water/Sanitary
FiledStatusContractorScope
05/10/2023Signed-offPLBG P & H INCGas, Water/Sanitary
1 project · most recent 04/12/2024
General Wiring Lighting
FiledStatusContractorScope
04/12/2024CompleteBDS ELECTRIC CORP.General Wiring, Lighting
▾Field Inspections (DOB CAP) — 3
DateTypeResultReport
10/11/2023Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
10/11/2023Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
05/31/2023Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 4
DateRequirementInspectorRole
05/09/2023Fire-Resistant Penetrations and JointsTerry Fuquaspecial
08/26/2022Energy Code Compliance InspectionsTerry Fuquaprogress
07/01/2022Mechanical SystemsTerry Fuquaspecial
07/01/2022FinalTerry Fuquaprogress
▾Documents — 62 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch4
08/28/2026B00768337-I1Request digital key ↗
08/28/2026B00768337-P1Request digital key ↗
08/15/2026B00768338-I1Request digital key ↗
Showing 3 of 4 on file for this type
▸Applications & Permits11
▸BISPLAN / WORK APPROVAL APPLICATION6
02/11/2010310044779Open ↗
10/28/2008310044779Open ↗
08/01/2008310177037Open ↗
Showing 3 of 6 on file for this type
▸BISWORK PERMIT APPLICATION5
02/20/2009310044779Open ↗
08/28/2008310177037Open ↗
03/17/2008310107693Open ↗
Showing 3 of 5 on file for this type
▸Seals & Professional Certifications11
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION6
04/21/2010310177037Open ↗
04/06/2010310044779Open ↗
03/29/2010310044779Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature4
08/28/2026B00768336-I1Open ↗
08/28/2026B00768337-I1Open ↗
08/28/2026B00768337-P1Open ↗
Showing 3 of 4 on file for this type
▸BISPC FULL REPORT1
11/02/2007310044779Open ↗
▸Trade Schedules & Equipment5
▸BISSELF-CERT PLUMBING NOTICE2
04/29/2008310044779Open ↗
04/08/2008310044779Open ↗
▸BISEQUIPMENT USE PERMITS1
04/01/2010310044779Open ↗
▸BISSCHEDULE B - PLUMBING1
04/11/2008310044779Open ↗
▸BISEQUIPMENT USE APPLICATION/PERMIT1
03/29/2010310044779Open ↗
▸Safety & Tenant Protection1
▸BISSTREET TREE CHECKLIST1
08/01/2008310177037Open ↗
▸Environmental & Asbestos7
▸DOB NOWDEP ACP-5: Asbestos Assessment Report4
08/28/2026B00768337-P1Open ↗
08/28/2026B00768337-I1Open ↗
08/15/2026B00768336-I1Open ↗
Showing 3 of 4 on file for this type
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'2
08/01/2008310177037Open ↗
03/07/2008310107693Open ↗
▸BISASBESTOS EXEMPTION CERTIFICATION LETTER1
11/02/2007310044779Open ↗
▸Inspections & Test Reports1
▸BISNOTIF.-PROPOSED STEAM/HOT WATER INSPECTION1
04/08/2008310044779Open ↗
▸Approvals, Objections & Sign-offs13
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST9
04/21/2010310177037Open ↗
04/06/2010310044779Open ↗
03/29/2010310044779Open ↗
Showing 3 of 9 on file for this type
▸BISADMINISTRATIVE OBJECTIONS3
08/01/2008310177037Open ↗
03/07/2008310107693Open ↗
11/02/2007310044779Open ↗
▸BISSCHEDULE A - OCCUPANCY / USE1
07/22/2008310044779Open ↗
▸Cost, Insurance & Ownership6
▸BISCOST AFFIDAVIT6
01/21/2010310044779Open ↗
01/04/2010310177037Open ↗
08/25/2008310177037Open ↗
Showing 3 of 6 on file for this type
▸Filing & Intake Forms2
▸BISEFILING COVER SHEET2
08/01/2008310177037Open ↗
03/07/2008310107693Open ↗
▸Other Documents1
▸BISFIRE SUPP ANSUL APPROVL: FD-FSS1
04/25/2008310044779Open ↗