← Back
QUEENS
151-57 GAR 20 AVENUE
QUEENS · Whitestone-Beechhurst · BIN 4623951
💬 Discuss this project
—Year Built
—Stories
—Building Class
—Zoning
—Gross Floor Area
—Units
Flood zone X
Locations of Work
ArchitecturePlumbing
Floor 13p · 1 filing · 20 docs
Site & exterior1 filing · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
KAISHENG GROUP LLC1303/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
AMERILAND BROOK LLC301/26/2024
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
DYNASTY CONTRACTING LLCGeneral Contractor303/21/2026
KWONG MING ELECTRIC INCElectrical103/22/2026
WATSON'S PLBG, HTG, & BDGPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
AMERILAND BROOK LLC1506210/19/2023
Building Lifecycle
All (23)Filed (3)Permit Issued (2)Signed Off (2)Inspection (6)Special Inspection (10)
04/12/2024
Signed off — New Building
INSTALL STORM DRAINAGE PIPING AT OSP; DETENTION TANK FILED UNDER JOB#Q00669891
Q00874295-I1
02/27/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
02/21/2024
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
02/01/2024
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
01/26/2024
Filed — New Building
INSTALL STORM DRAINAGE PIPING AT OSP; DETENTION TANK FILED UNDER JOB#Q00669891
Q00874295-S2
01/10/2024
Signed off — New Building
INSTALL STORM DRAINAGE PIPING AT OSP; DETENTION TANK FILED UNDER JOB#Q00669891
Q00874295-S1
01/01/2024
Inspection — Certified Storm Drainage-ST-Fixtures-Finish
Certified
View inspection ↗
12/29/2023
Inspection — Certified Storm Drainage-ST-Piping-Roughing
Certified
View inspection ↗
12/29/2023
Inspection — Certified Storm Drainage-ST-Piping-Underground
Certified
View inspection ↗
12/12/2023
Permit issued — Plumbing
Q00874295-S1-PL
10/25/2023
Permit issued — General Construction
Q00874295-I1-GC-CX
10/19/2023
Filed — New Building
INSTALL STORM DRAINAGE PIPING AT OSP; DETENTION TANK FILED UNDER JOB#Q00669891
Q00874295-S1
10/19/2023
Special inspection requirement — Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation
XIAOHONG ZHAO
05/12/2023
Filed — New Building
INSTALL STORM DRAINAGE PIPING AT OSP; DETENTION TANK FILED UNDER JOB#Q00669891
Q00874295-I1
05/12/2023
Special inspection requirement — Concrete - Cast-In-Place
XIAOHONG ZHAO
05/12/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
XIAOHONG ZHAO
05/12/2023
Special inspection requirement — Masonry
XIAOHONG ZHAO
05/12/2023
Special inspection requirement — Final
XIAOHONG ZHAO
05/12/2023
Special inspection requirement — Footing and Foundation
XIAOHONG ZHAO
05/12/2023
Special inspection requirement — Energy Code Compliance Inspections
XIAOHONG ZHAO
05/12/2023
Special inspection requirement — Fire-Resistance Rated Construction
XIAOHONG ZHAO
05/12/2023
Special inspection requirement — Electric vehicle service equipment requirements
XIAOHONG ZHAO
05/12/2023
Special inspection requirement — Interior lighting power
XIAOHONG ZHAO
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offWATSON'S PLBG, HTG, & BDG12/12/2023
DOB NOWGeneral ConstructionPermit IssuedDYNASTY CONTRACTING LLC10/25/2023
1 project · most recent 01/26/2024
Storm
FiledStatusContractorScope
01/26/2024Signed-offWATSON'S PLBG, HTG, & BDGStorm
1 project · most recent 10/27/2023
General Wiring
FiledStatusContractorScope
10/27/2023CompleteKWONG MING ELECTRIC INCGeneral Wiring
▾Field Inspections (DOB CAP) — 6
DateTypeResultReport
02/27/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
02/21/2024Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
02/01/2024Pass-Final CND-Occupancy InspectionPassView ↗
01/01/2024Certified Storm Drainage-ST-Fixtures-FinishCertifiedView ↗
12/29/2023Certified Storm Drainage-ST-Piping-RoughingCertifiedView ↗
12/29/2023Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 10
DateRequirementInspectorRole
10/19/2023Private On-Site Storm Water Disposal Systems-, and Detention Facilities, InstallationXIAOHONG ZHAOspecial
05/12/2023Concrete - Cast-In-PlaceXIAOHONG ZHAOspecial
05/12/2023Fire-Resistant Penetrations and JointsXIAOHONG ZHAOspecial
05/12/2023MasonryXIAOHONG ZHAOspecial
05/12/2023FinalXIAOHONG ZHAOprogress
05/12/2023Footing and FoundationXIAOHONG ZHAOprogress
05/12/2023Energy Code Compliance InspectionsXIAOHONG ZHAOprogress
05/12/2023Fire-Resistance Rated ConstructionXIAOHONG ZHAOprogress
05/12/2023Electric vehicle service equipment requirementsXIAOHONG ZHAOenergy_progress
05/12/2023Interior lighting powerXIAOHONG ZHAOenergy_progress
▾Documents — 50 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch3
08/24/2026Q00874295-S1Request digital key ↗
08/24/2026Q00874295-I1Request digital key ↗
08/24/2026Q00874295-S2Request digital key ↗
▸Applications & Permits4
▸BISPLAN / WORK APPROVAL APPLICATION4
01/25/2024421888513Open ↗
04/21/2020421888513Open ↗
07/16/2019421888513Open ↗
Showing 3 of 4 on file for this type
▸Zoning, Tax Lot & Property Records9
▸DOB NOWRestrictive Declaration/Easement 13
08/13/2026Q00874295-I1Open ↗
08/13/2026Q00874295-S2Open ↗
08/13/2026Q00874295-S1Open ↗
▸BISEASEMENT AND RESTRICTIVE DECLARATIONS - SUPPPORTING DOCUMENTATION1
05/01/2020421888513Open ↗
▸BISZONING DIAGRAM1
05/01/2020421888513Open ↗
▸BISTAX LOT: TENTATIVE LOT NUMBER ISSUED1
05/01/2020421888513Open ↗
▸DOB NOWZD1: DOB Zoning Diagram1
08/13/2026Q00874295-I1Open ↗
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026Q00874295-I1Open ↗
▸DOB NOWZoning Exhibit form (1-5)1
08/13/2026Q00874295-I1Open ↗
▸Seals & Professional Certifications11
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/24/2026Q00874295-S1Open ↗
08/24/2026Q00874295-I1Open ↗
08/24/2026Q00874295-S2Open ↗
▸DOB NOWProgress Inspector Seal & Signature3
08/26/2026Q00874295-I1Open ↗
08/26/2026Q00874295-I1Open ↗
08/26/2026Q00874295-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
08/26/2026Q00874295-I1Open ↗
08/24/2026Q00874295-S1Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
07/16/2019421888513Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
07/16/2019421888513Open ↗
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION1
07/16/2019421888513Open ↗
▸Trade Schedules & Equipment2
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE1
07/16/2019421888513Open ↗
▸DOB NOWDEP: Sewer Certification (Sanitary/Storm)1
08/13/2026Q00874295-I1Open ↗
▸Safety & Tenant Protection6
▸BISSTREET TREE CHECKLIST3
05/01/2020421888513Open ↗
07/25/2019421888513Open ↗
07/16/2019421888513Open ↗
▸DOB NOWStreet Tree Checklist1
08/13/2026Q00874295-I1Open ↗
▸DOB NOWStreet Tree Sign Off1
08/13/2026Q00874295-I1Open ↗
▸DOB NOWStreet Trees Site Plan1
08/13/2026Q00874295-I1Open ↗
▸Energy Compliance3
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS2
07/25/2019421888513Open ↗
07/16/2019421888513Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY1
05/01/2020421888513Open ↗
▸Inspections & Test Reports1
▸BISTECHNICAL REPORT: RESPONSIBILITY1
05/01/2020421888513Open ↗
▸Approvals, Objections & Sign-offs3
▸BISSCHEDULE A - OCCUPANCY / USE2
04/21/2020421888513Open ↗
07/16/2019421888513Open ↗
▸BISLETTERS - SUPPORTING DOCUMENTATION1
05/01/2020421888513Open ↗
▸Filing & Intake Forms1
▸BISEFILING COVER SHEET1
07/16/2019421888513Open ↗
▸Other Documents7
▸BISPLOT DIAGRAM1
07/16/2019421888513Open ↗
▸BISSUSTAINABLE ROOF ZONE FORM1
05/01/2020421888513Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone1
08/13/2026Q00874295-I1Open ↗
▸DOB NOWAdjoining Owners Notification1
08/13/2026Q00874295-I1Open ↗
▸DOB NOWProperty Ownership Certification1
08/24/2026Q00874295-I1Open ↗
▸DOB NOWSite Survey: Initial1
08/13/2026Q00874295-I1Open ↗
▸DOB NOWFinal Survey1
08/13/2026Q00874295-I1Open ↗