← Back
Two family frame
151 CENTRAL AVENUE
BROOKLYN · BIN 3347836
💬 Discuss this project
2001Year Built
2Stories
B2Building Class
R6Zoning
2,112 sfGross Floor Area
2Units
0 Open ViolationsFDNY Report ↗
Two family frame · 2,100 sf lot · 1.01 FAR built · Flood zone X
Locations of Work
Architecture
Floor 22p · 1 filing · 5 docs
Floor 12p · 1 filing · 5 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
HPD 806103/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
01/17/2025$1.3M—Private party → Private party$608/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
PERMIT ARCHITECTS106/01/2026
HAMIDE RIHTIM203/19/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
EC BUILDING CONSULTANTS403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
PASQUALE QUARATINO INCGeneral Contractor503/21/2026
PASQUALE QUARATINO INCPlumbing507/08/2026
Building Lifecycle
All (29)Filed (3)Permit Issued (2)Violation (1)Inspection (3)Objection (10)Special Inspection (10)
07/30/2026
Objection resolved — Addressed
07/30/2026
Objection resolved — Addressed
07/30/2026
Objection resolved — Addressed
07/30/2026
Objection resolved — Addressed
07/30/2026
Objection resolved — Addressed
06/08/2026
Objection raised — Other
06/08/2026
Objection raised — Other
06/08/2026
Objection raised — Other
06/08/2026
Objection raised — Other
06/08/2026
Objection raised — Other
06/01/2026
Filed — Alteration
IN UNIT 1 ON FLOOR 1 OF EXIST. 2-FAM HOUSE, REMOVAL OF WINDOW AND INSTALLATION OF DOOR AND WINDOW, AND EXTERIOR STAIR AS SHOWN ON PLANS. NO CHANGE TO EGRESS, USE, OR OCCUPANCY.
B01409139-I1
05/29/2026
Special inspection requirement — Footing and Foundation
05/29/2026
Special inspection requirement — Concrete - Cast-In-Place
05/29/2026
Special inspection requirement — Post-installed Anchors
05/29/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
05/29/2026
Special inspection requirement — Structural Steel - Welding
05/29/2026
Special inspection requirement — Subgrade Inspections
05/29/2026
Special inspection requirement — Structural Steel - Details
05/29/2026
Special inspection requirement — Energy Code Compliance Inspections
George Showman
05/29/2026
Special inspection requirement — Final
George Showman
10/29/2025
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
10/15/2025
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
05/08/2025
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
03/31/2025
Permit issued — General Construction
B01197477-I1-GC
03/31/2025
Permit issued — Plumbing
B01197477-S1-PL
03/19/2025
Filed — Alteration
REMOVING AND INSTALLING NEW PLUMBING FIXTURES AS SHOWN ON DRAWINGS. NO CHANGE TO OCCUPANCY USE OR EGRESS.
B01197477-I1
03/19/2025
Filed — Alteration
REMOVING AND INSTALLING NEW PLUMBING FIXTURES AS SHOWN ON DRAWINGS. NO CHANGE TO OCCUPANCY USE OR EGRESS.
B01197477-S1
03/19/2025
Special inspection requirement — Final
William Alicea
12/14/1995
Violation issued (ECB, closed)
Zoning
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionPermit IssuedNot Applicable03/31/2025
DOB NOWPlumbingSigned-offPASQUALE QUARATINO INC03/31/2025
BIS—ISSUEDBANTA HOMES CORP.06/10/2002
BIS—ISSUEDBANTA HOMES CORP.02/20/2002
BISPLISSUEDTRI CITY MECHANICAL GROUP CORP10/09/2001
BIS—ISSUEDBANTA HOMES CORP.02/07/2001
1 project · most recent 03/19/2025
Water/Sanitary
FiledStatusContractorScope
03/19/2025Signed-offPASQUALE QUARATINO INCWater/Sanitary
1 project · most recent 06/01/2026
Steel
FiledStatusContractorScope
06/01/2026——Steel
▾Field Inspections (DOB CAP) — 3
DateTypeResultReport
10/29/2025Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
10/15/2025Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
05/08/2025Pass-Final PL - Up to 3 Requested FloorsPassView ↗
▾Special Inspection Requirements (DOB NOW) — 10
DateRequirementInspectorRole
05/29/2026Footing and Foundation—progress
05/29/2026Concrete - Cast-In-Place—special
05/29/2026Post-installed Anchors—special
05/29/2026Structural Stability – Alterations of existing buildings—special
05/29/2026Structural Steel - Welding—special
05/29/2026Subgrade Inspections—special
05/29/2026Structural Steel - Details—special
05/29/2026Energy Code Compliance InspectionsGeorge Showmanprogress
05/29/2026FinalGeorge Showmanprogress
03/19/2025FinalWilliam Aliceaprogress
▾Documents — 9 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch3
08/22/2026B01197477-I1Request digital key ↗
08/22/2026B01197477-S1Request digital key ↗
08/14/2026B01409139-I1Request digital key ↗
▸Seals & Professional Certifications6
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/22/2026B01197477-I1Open ↗
08/22/2026B01197477-S1Open ↗
08/16/2026B01409139-I1Open ↗
▸DOB NOWProgress Inspector Seal & Signature3
08/26/2026B01409139-I1Open ↗
08/26/2026B01409139-I1Open ↗
08/24/2026B01197477-I1Open ↗