← Back
Four families
151 LEONARD STREET
BROOKLYN · BIN 3070871
💬 Discuss this project
1920Year Built
3Stories
C3Building Class
R6BZoning
2,310 sfGross Floor Area
4Units
Rent Stabilized1 Open Violation ▸FDNY Report ↗
Four families · 5,000 sf lot · 0.46 FAR built · Flood zone X
Locations of Work
No floor-level scope or drawing coverage on file for this building.
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
STRUCTURAL ENGINEERING TECHNOLOGIES412/18/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
AVALON DESIGNS803/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
INNOVATIVE CONSTR NYC LLCGeneral Contractor407/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
HRF SERVICES CORP5616210/01/2024
Building Lifecycle
All (39)Filed (4)Permit Issued (2)Signed Off (2)Violation (10)Objection (7)Special Inspection (14)
05/05/2026
Violation issued (HPD, closed)
A
06/17/2025
Signed off — Alteration
Demolition of collapsed concrete wall during adjacent neighbor full demolition
B01116426-I1
06/10/2025
Signed off — Alteration
B01111115-I1
01/14/2025
Permit issued — Structural
B01116426-I1-ST
01/09/2025
Permit issued — Foundation
B01111115-I1-FO
12/18/2024
Filed — Alteration
Demolition of collapsed concrete wall during adjacent neighbor full demolition
B01116426-P1
12/11/2024
Special inspection requirement — Construction Operations Influencing Adjacent Structures
12/11/2024
Special inspection requirement — Final
12/11/2024
Special inspection requirement — Structural Stability – Alterations of existing buildings
12/11/2024
Special inspection requirement — Demolition
11/25/2024
Violation issued (HPD, closed)
I
11/05/2024
Special inspection requirement — Excavations - Sheeting, Shoring, and Bracing
FAHAD FATEH
11/05/2024
Special inspection requirement — Post-installed Anchors
FAHAD FATEH
10/17/2024
Special inspection requirement — Structural Stability – Alterations of existing buildings
FAHAD FATEH
10/15/2024
Objection resolved — Addressed
10/15/2024
Objection resolved — Addressed
10/15/2024
Objection resolved — Addressed
10/10/2024
Objection raised — Other
10/10/2024
Objection raised — Other
10/10/2024
Objection raised — Other
10/01/2024
Filed — Alteration
Demolition of collapsed concrete wall during adjacent neighbor full demolition
B01116426-I1
10/01/2024
Filed — Alteration
B01111115-I1
09/20/2024
Objection raised — Other
09/13/2024
Special inspection requirement — Footing and Foundation
FAHAD FATEH
09/13/2024
Special inspection requirement — Final
FAHAD FATEH
09/13/2024
Special inspection requirement — Subgrade Inspections
FAHAD FATEH
09/13/2024
Special inspection requirement — Concrete - Cast-In-Place
FAHAD FATEH
09/11/2024
Filed — Full Demolition
B01090065-I1
08/09/2024
Special inspection requirement — Construction Operations Influencing Adjacent Structures
08/09/2024
Special inspection requirement — Demolition
08/09/2024
Special inspection requirement — Structural Stability – Alterations of existing Buildings
08/01/2024
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
07/01/2024
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
04/10/2024
Violation issued (HPD, closed)
A
03/23/2023
Violation issued (HPD, closed)
A
11/07/2022
Violation issued (HPD, closed)
I
02/25/2022
Violation issued (HPD, closed)
A
02/25/2022
Violation issued (HPD, closed)
I
04/09/2021
Violation issued (HPD, closed)
A
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWStructuralSigned-offINNOVATIVE CONSTR NYC LLC01/14/2025
DOB NOWFoundationSigned-offINNOVATIVE CONSTR NYC LLC01/09/2025
Nothing on file for this building.
▾Special Inspection Requirements (DOB NOW) — 14
DateRequirementInspectorRole
12/11/2024Construction Operations Influencing Adjacent Structures—special
12/11/2024Final—progress
12/11/2024Structural Stability – Alterations of existing buildings—special
12/11/2024Demolition—special
11/05/2024Excavations - Sheeting, Shoring, and BracingFAHAD FATEHspecial
11/05/2024Post-installed AnchorsFAHAD FATEHspecial
10/17/2024Structural Stability – Alterations of existing buildingsFAHAD FATEHspecial
09/13/2024Footing and FoundationFAHAD FATEHprogress
09/13/2024FinalFAHAD FATEHprogress
09/13/2024Subgrade InspectionsFAHAD FATEHspecial
09/13/2024Concrete - Cast-In-PlaceFAHAD FATEHspecial
08/09/2024Construction Operations Influencing Adjacent Structures—special
08/09/2024Demolition—special
08/09/2024Structural Stability – Alterations of existing Buildings—special
▾Documents — 11 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch4
08/24/2026B01090065-I1Request digital key ↗
08/24/2026B01111115-I1Request digital key ↗
08/24/2026B01116426-P1Request digital key ↗
Showing 3 of 4 on file for this type
▸Seals & Professional Certifications5
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/24/2026B01111115-I1Open ↗
08/24/2026B01116426-I1Open ↗
08/24/2026B01116426-P1Open ↗
▸DOB NOWProgress Inspector Seal & Signature1
08/29/2026B01111115-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/29/2026B01111115-I1Open ↗
▸Inspections & Test Reports1
▸DOB NOWGeotechnical Report (BC 1803.6)1
08/13/2026B01111115-I1Open ↗
▸Other Documents1
▸DOB NOWPARTIAL DEMO: 10-DAY Notice1
08/13/2026B01116426-I1Open ↗