← Back
BROOKLYN
The 151 Newel Street Condominium
151 NEWELL STREET · BIN 3065759
💬 Discuss this project
—Year Built
—Stories
—Building Class
—Zoning
—Gross Floor Area
—Units
0 Open ViolationsFDNY Report ↗
Flood zone X
Locations of Work
ArchitectureStructuralElectricalMechanicalPlumbingFire Protection
Roof3p · 2 filings · 16 docs
Bulkhead4p · 3 filings · 20 docs
Floor 43p · 2 filings · 20 docs
Floor 34p · 3 filings · 20 docs
Floor 24p · 4 filings · 20 docs
Floor 14p · 2 filings · 16 docs
Cellar6p · 4 filings · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
168 EVERGREEN5807/08/2026
OWNERS REP1003/22/2026
FIRST WORLD DEVELOPMENT303/22/2026
E M BUILDERS GROUP603/22/2026
151 NEWEL603/21/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
02/10/2021$1.4M—— → —— not available
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
ALL CITY ENGINEERING, P.C.706/09/2023
PAUL PERDEK, PROF. ENG. PLLC910/26/2022
SHARON ENGINEERING, P.C807/18/2022
ASHRAF CORP107/09/2021
STUDIOSC ARCHITECTURE PLLC105/07/2021
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
BMB BUILDING CONSULTING3203/21/2026
DANICO SERVICES203/21/2026
AE DESIGN SOLUTION1803/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
E&M BUILDERS GROUP CORPGeneral Contractor2107/08/2026
CORE SCAFFOLD SYSTEMS INC.General Contractor1007/08/2026
CENTRAL SCAFFOLD & HOISTGeneral Contractor603/21/2026
PLBG P & H INCPlumbing407/08/2026
BRUCHE MECHANICAL NY LLCFire Protection207/08/2026
PLBGGeneral Contractor203/22/2026
LAKHI GENERAL CONTRACTORGeneral Contractor107/08/2026
STEPHEN CONTEElectrical103/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
HRF SERVICES CORP56161506/09/2023
Building Lifecycle
All (159)Filed (26)Permit Issued (20)Signed Off (12)Violation (17)Inspection (6)Objection (48)Special Inspection (30)
07/06/2023
Signed off — Alteration
PROPOSE PLUMBING WORKS IN CONJUNCTION WITH NB#321600157
B00491398-I1
06/20/2023
Signed off — Alteration
PROPOSE MECHANICAL SCOPE OF WORK FILED IN CONJUNCTION WITH NB#321600157
B00491408-I1
06/16/2023
Special inspection requirement — HVAC-R and service water heating system controls
FAHAD FATEH
06/16/2023
Special inspection requirement — HVAC-R and service water heating equipment
FAHAD FATEH
06/16/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
FAHAD FATEH
06/16/2023
Special inspection requirement — Energy Code Compliance Inspections
FAHAD FATEH
06/16/2023
Special inspection requirement — Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation
FAHAD FATEH
06/16/2023
Special inspection requirement — Maintenance information
FAHAD FATEH
06/16/2023
Special inspection requirement — HVAC-R and service water piping design and insulation
FAHAD FATEH
06/16/2023
Special inspection requirement — Metering
FAHAD FATEH
06/15/2023
Signed off — Alteration
Propose Sprinkler scope of work filed in conjunction with NB # 321600157
B00509293-I1
06/09/2023
Filed — Alteration
PROPOSE PLUMBING WORKS IN CONJUNCTION WITH NB#321600157
B00491398-P3
06/06/2023
Special inspection requirement — Energy Code Compliance Inspections
FAHAD FATEH
06/06/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
FAHAD FATEH
06/06/2023
Special inspection requirement — Metering
FAHAD FATEH
06/06/2023
Special inspection requirement — HVAC-R and service water heating system controls
FAHAD FATEH
06/06/2023
Special inspection requirement — HVAC-R and service water piping design and insulation
FAHAD FATEH
06/06/2023
Special inspection requirement — Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation
FAHAD FATEH
06/06/2023
Special inspection requirement — HVAC-R and service water heating equipment
FAHAD FATEH
06/06/2023
Special inspection requirement — Maintenance information
FAHAD FATEH
05/23/2023
Signed off — Alteration
INSTALLATION OF HEAVYDUTY SIDEWALK SHED AS PER PLANS. NO CHANGE IN USE OCCUPANCY OR EGRESS UNDER THIS APPLICATION. NO CHANGE IN USE OCCUPANCY OR EGRESS UNDER THIS APPLICATION.
B00552279-I1
05/19/2023
Filed — Alteration
PROPOSE PLUMBING WORKS IN CONJUNCTION WITH NB#321600157
B00491398-P2
05/18/2023
Signed off — Alteration
Propose to install temporary construction fence at sidewalk total 133.00 LF as per drawings in connection with NB # 321600157.
B00515689-I1
03/30/2023
Inspection — Certified Sprinkler-SP-Fixtures-Finish
Certified
View inspection ↗
03/27/2023
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
03/03/2023
Permit issued — Sprinklers
B00509293-I1-EW-SP
03/02/2023
Permit issued — Plumbing
B00491398-I1-PL
02/21/2023
Signed off — Alteration
PROPOSE STRUCTURAL WORKS IN CONJUNCTION WITH NB #321600157
B00491680-I1
02/17/2023
Signed off — Alteration
PROPOSE EARTH WORK & FOUNDATION WORKS IN CONJUNCTION WITH NB #321600157
B00493594-I1
02/17/2023
Signed off — Alteration
PROPOSE EARTH WORK & FOUNDATION WORKS IN CONJUNCTION WITH NB #321600157
B00493594-S2
01/23/2023
Violation issued (ECB, closed)
Construction
01/09/2023
Signed off — Alteration
INSTALLATION OF TEMPORARY SIDEWALK SHED AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B00737419-I1
01/03/2023
Signed off — Alteration
INSTALLATION OF TEMPORARY OVERHEAD PROTECTION AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B00738697-I1
12/22/2022
Signed off — Alteration
INSTALLATION OF TEMPORARY ROOF PROTECTION AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B00793753-I1
12/22/2022
Signed off — Alteration
INSTALLATION OF TEMPORARY PIPE SCAFFOLD AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B00737424-I1
12/02/2022
Violation issued (ECB, closed)
Construction
11/17/2022
Permit issued — Mechanical Systems
B00491408-I1-MS
11/04/2022
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
11/04/2022
Inspection — Certified Storm Drainage-ST-Piping-Roughing
Certified
View inspection ↗
10/28/2022
Permit issued — Construction Fence
B00515689-I1-FN
10/26/2022
Filed — Alteration
INSTALLATION OF TEMPORARY PIPE SCAFFOLD AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B00737424-P1
10/14/2022
Permit issued — Construction Fence
B00515689-I1-FN
08/20/2022
Permit issued — Protection and Mechanical Methods
B00793753-I1-PM
08/18/2022
Filed — Alteration
INSTALLATION OF TEMPORARY ROOF PROTECTION AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B00793753-I1
08/16/2022
Filed — Alteration
INSTALLATION OF TEMPORARY SIDEWALK SHED AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B00737419-P2
08/16/2022
Filed — Alteration
INSTALLATION OF TEMPORARY OVERHEAD PROTECTION AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B00738697-P2
08/01/2022
Permit issued — Supported Scaffold
B00737424-I1-SF
07/29/2022
Filed — Alteration
INSTALLATION OF TEMPORARY PIPE SCAFFOLD AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B00737424-I1
07/25/2022
Filed — Alteration
INSTALLATION OF TEMPORARY OVERHEAD PROTECTION AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B00738697-P1
07/25/2022
Filed — Alteration
INSTALLATION OF TEMPORARY SIDEWALK SHED AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B00737419-P1
07/18/2022
Filed — Alteration
PROPOSE STRUCTURAL WORKS IN CONJUNCTION WITH NB #321600157
B00491680-P2
07/18/2022
Special inspection requirement — Sprayed fire-resistant materials
FAHAD FATEH
07/18/2022
Special inspection requirement — Post-installed Anchors
FAHAD FATEH
07/18/2022
Special inspection requirement — Structural Cold-Formed Steel
FAHAD FATEH
07/18/2022
Special inspection requirement — Structural Steel - Details
FAHAD FATEH
07/18/2022
Special inspection requirement — Masonry
FAHAD FATEH
07/18/2022
Special inspection requirement — Structural Steel - High Strength Bolting
FAHAD FATEH
07/18/2022
Special inspection requirement — Structural Steel - Welding
FAHAD FATEH
07/18/2022
Special inspection requirement — Concrete - Cast-In-Place
FAHAD FATEH
07/18/2022
Special inspection requirement — Final
FAHAD FATEH
Latest 60 of 159 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSprinklersSigned-offBRUCHE MECHANICAL NY LLC03/03/2023
DOB NOWPlumbingSigned-offPLBG P & H INC03/02/2023
DOB NOWMechanical SystemsSigned-offE&M BUILDERS GROUP CORP11/17/2022
DOB NOWConstruction FenceSigned-offE&M BUILDERS GROUP CORP10/28/2022
DOB NOWConstruction FenceSigned-offE&M BUILDERS GROUP CORP10/14/2022
DOB NOWProtection and Mechanical MethodsSigned-offCORE SCAFFOLD SYSTEMS INC08/20/2022
DOB NOWSupported ScaffoldSigned-offCORE SCAFFOLD SYSTEMS INC08/01/2022
DOB NOWProtection and Mechanical MethodsSigned-offCORE SCAFFOLD SYSTEMS INC06/30/2022
DOB NOWSidewalk ShedSigned-offCORE SCAFFOLD SYSTEMS INC06/30/2022
DOB NOWSidewalk ShedSigned-offCENTRAL SCAFFOLD & HOIST05/19/2022
DOB NOWProtection and Mechanical MethodsSigned-offCENTRAL SCAFFOLD & HOIST05/19/2022
DOB NOWStructuralSigned-offE&M BUILDERS GROUP CORP03/17/2022
DOB NOWFoundationSigned-offE&M BUILDERS GROUP CORP03/15/2022
DOB NOWSupport of ExcavationSigned-offE&M BUILDERS GROUP CORP02/07/2022
DOB NOWPlumbingSigned-offPLBG P & H INC01/24/2022
DOB NOWSprinklersSigned-offBRUCHE MECHANICAL NY LLC01/24/2022
DOB NOWMechanical SystemsSigned-offE&M BUILDERS GROUP CORP11/26/2021
DOB NOWConstruction FenceSigned-offE&M BUILDERS GROUP CORP10/18/2021
DOB NOWSidewalk ShedSigned-offLAKHI GENERAL CONTRACTOR07/12/2021
DOB NOWConstruction FenceSigned-offE&M BUILDERS GROUP CORP06/14/2021
BIS—ISSUEDE&M BUILDERS GROUP CORP10/25/2022
BIS—ISSUEDE&M BUILDERS GROUP CORP11/05/2021
BIS—ISSUEDFIRST WORLD DEVELOPMENT07/13/2021
4 projects · most recent 06/15/2023
General Wiring
FiledStatusContractorScope
06/15/2023CompleteLENS ELECTRIC, INCGeneral Wiring
03/07/2023CompleteKENNETH FISK ELECTRIC CORGeneral Wiring
06/02/2022CompleteV. VASS ELECTRIC CORP—
09/09/2021CompleteK.N.C ELECTRIC INC—
▾Field Inspections (DOB CAP) — 6
DateTypeResultReport
03/30/2023Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
03/27/2023Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
11/04/2022Certified Gas-Gas-Piping-RoughingCertifiedView ↗
11/04/2022Certified Storm Drainage-ST-Piping-RoughingCertifiedView ↗
05/12/2022Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
05/12/2022Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 87
DateRequirementInspectorRole
06/16/2023HVAC-R and service water heating system controlsFAHAD FATEHenergy_progress
06/16/2023Private On-Site Storm Water Disposal Systems-, and Detention Facilities, InstallationFAHAD FATEHspecial
06/16/2023HVAC-R and service water heating equipmentFAHAD FATEHenergy_progress
06/16/2023Maintenance informationFAHAD FATEHenergy_progress
06/16/2023HVAC-R and service water piping design and insulationFAHAD FATEHenergy_progress
06/16/2023MeteringFAHAD FATEHenergy_progress
06/16/2023Energy Code Compliance InspectionsFAHAD FATEHprogress
06/16/2023Fire-Resistant Penetrations and JointsFAHAD FATEHspecial
06/06/2023Energy Code Compliance InspectionsFAHAD FATEHprogress
06/06/2023Fire-Resistant Penetrations and JointsFAHAD FATEHspecial
06/06/2023Maintenance informationFAHAD FATEHenergy_progress
06/06/2023HVAC-R and service water heating system controlsFAHAD FATEHenergy_progress
06/06/2023HVAC-R and service water heating equipmentFAHAD FATEHenergy_progress
06/06/2023HVAC-R and service water piping design and insulationFAHAD FATEHenergy_progress
06/06/2023MeteringFAHAD FATEHenergy_progress
06/06/2023Private On-Site Storm Water Disposal Systems-, and Detention Facilities, InstallationFAHAD FATEHspecial
07/18/2022Structural Steel - DetailsFAHAD FATEHspecial
07/18/2022Structural Steel - High Strength BoltingFAHAD FATEHspecial
07/18/2022Structural Steel - WeldingFAHAD FATEHspecial
07/18/2022FinalFAHAD FATEHprogress
07/18/2022Concrete - Cast-In-PlaceFAHAD FATEHspecial
07/18/2022MasonryFAHAD FATEHspecial
07/18/2022Post-installed AnchorsFAHAD FATEHspecial
07/18/2022Sprayed fire-resistant materialsFAHAD FATEHspecial
07/18/2022Structural Cold-Formed SteelFAHAD FATEHspecial
Latest 25 of 87.
▾Documents — 188 on file (BIS + DOB NOW)
▸Plans & Drawings24
▸DOB NOWPlans/Sketch24
09/01/2026B00509293-I1Request digital key ↗
09/01/2026B00509293-P1Request digital key ↗
09/01/2026B00552279-I1Request digital key ↗
Showing 3 of 24 on file for this type
▸Applications & Permits18
▸BISPLAN / WORK APPROVAL APPLICATION12
06/23/2023321600157Open ↗
05/02/2023321600157Open ↗
05/01/2023322160558Open ↗
Showing 3 of 12 on file for this type
▸BISBPP-5 - Authorization to the Department of Transportation2
07/20/2021340810144Open ↗
04/21/2021340810144Open ↗
▸BISWORK PERMIT APPLICATION2
11/08/2021321600157Open ↗
07/14/2021322094149Open ↗
▸BISPLAN - WORK & PERMITS - SUPPPORTING DOCUMENTATION1
05/04/2023322160558Open ↗
▸BISCERTIFICATE OF OCCUPANCY: APPLICATION1
01/12/2023321600157Open ↗
▸Zoning, Tax Lot & Property Records10
▸BISZONING EXHIBIT III:DESC. & OWNRSHP.STMNT2
05/04/2023322160558Open ↗
04/19/2021321600157Open ↗
▸BISZONING EXHIBIT I: CERTIFICATION2
05/04/2023322160558Open ↗
04/19/2021321600157Open ↗
▸BISADDRESS: NEW HOUSE NUMBER APPROVED2
05/04/2023322160558Open ↗
04/19/2021321600157Open ↗
▸BISTAX LOT: TENTATIVE LOT NUMBER ISSUED1
05/04/2023322160558Open ↗
▸BISVERIFY TAX LOT1
06/06/2023321600157Open ↗
▸BISCO OBJ: VERIFY ADDRESS-TOPO STAMP1
06/07/2023321600157Open ↗
▸BISZONING DIAGRAM1
05/28/2021321600157Open ↗
▸Seals & Professional Certifications55
▸DOB NOWDPL-1: Design Professional Seal & Signature25
08/29/2026B00738697-I1Open ↗
08/29/2026B00738697-P1Open ↗
08/29/2026B00737419-I1Open ↗
Showing 3 of 25 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature15
09/01/2026B00493594-S2Open ↗
08/29/2026B00509293-I1Open ↗
08/29/2026B00493594-P3Open ↗
Showing 3 of 15 on file for this type
▸DOB NOWProgress Inspector Seal & Signature13
08/29/2026B00493594-P3Open ↗
08/27/2026B00491398-I1Open ↗
08/27/2026B00491398-I1Open ↗
Showing 3 of 13 on file for this type
▸BISAPPLICANT OWNER SIGNATURE1
04/21/2021340810144Open ↗
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION1
11/08/2021321600157Open ↗
▸Trade Schedules & Equipment4
▸BISDEP STORMWATER SEWER CERTIFICATION (HCP/SCP)1
04/19/2021321600157Open ↗
▸BISDETECTOR:SMOKE-CERT. OF INSTALLATION1
08/14/2023321600157Open ↗
▸BISDEP SANITARY SEWER CERTIFICATION (HCP/SCP)1
06/06/2023321600157Open ↗
▸BISFA - FDNY APPROVAL : FD-FAA1
08/14/2023321600157Open ↗
▸Safety & Tenant Protection7
▸BISSTREET TREE CHECKLIST2
04/21/2021340810144Open ↗
04/19/2021321600157Open ↗
▸BISSTREET TREES: RECEIPT OF STREET TREES SITE PLAN1
04/21/2021340810144Open ↗
▸BISBPP: STREET TREES SITE PLAN1
06/01/2021340810144Open ↗
▸BISSTREET TREE SIGNOFF1
06/06/2023321600157Open ↗
▸BISSTREET TREES SITE PLAN1
06/25/2021340810144Open ↗
▸BISDEMOLITION SUBMITTAL CERTIFICATION FORM1
07/14/2021322094149Open ↗
▸Energy Compliance16
▸DOB NOWEN2: As Built Energy Analysis.2
08/13/2026B00491408-I1Open ↗
08/13/2026B00491398-I1Open ↗
▸BISFENESTRATION U-FACTOR & PRODUCT RATING1
06/15/2023321600157Open ↗
▸BISFENESTRATION AREAS1
06/15/2023321600157Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY1
05/07/2021321600157Open ↗
▸BISINSULATION PLACEMENT & R VALUES1
06/15/2023321600157Open ↗
▸BISLIGHTING IN DWELLING UNITS1
06/15/2023321600157Open ↗
▸BISENERGY CODE COMPLIANCE INSPECTIONS1
06/15/2023321600157Open ↗
▸BISLIGHTING CONTROLS1
06/15/2023321600157Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS1
11/08/2021321600157Open ↗
▸BISAS-BUILT ENERGY ANALYSIS (EN2)1
06/15/2023321600157Open ↗
▸BISELECTRICAL ENERGY CONSUMPTION1
06/15/2023321600157Open ↗
▸BISEXTERIOR LIGHTING POWER1
06/15/2023321600157Open ↗
▸BISFENESTRATION AIR LEAKAGE1
06/15/2023321600157Open ↗
▸BISAIR SEALING AND INSULATION - VISUAL1
06/15/2023321600157Open ↗
▸BISINTERIOR LIGHTING POWER1
06/15/2023321600157Open ↗
▸Inspections & Test Reports16
▸BISTECHNICAL REPORT: RESPONSIBILITY3
05/19/2021321600157Open ↗
05/19/2021321600157Open ↗
05/19/2021321600157Open ↗
▸DOB NOWSOIL REPORT3
08/13/2026B00493594-I1Open ↗
08/13/2026B00493594-P3Open ↗
08/13/2026B00493594-P2Open ↗
▸BISTECHNICAL REPORT: CONCRETE/TEST CYLINDER2
08/15/2023321600157Open ↗
11/08/2021321600157Open ↗
▸BISFIRE-RESISTANT PENETRATIONS AND JOINTS (FIRESTOP)1
06/15/2023321600157Open ↗
▸BISFIRE-RESISTIVE RATED CONSTRUCTION1
06/15/2023321600157Open ↗
▸BISSOIL REPORT1
05/19/2021321600157Open ↗
▸BISTECHNICAL REPORT: SOIL INSPECTION1
05/19/2021321600157Open ↗
▸BISTECHNICAL REPORT: CONCRETE DESIGN MIX1
11/08/2021321600157Open ↗
▸BISDEMOLITION (DM) JOB SIGNOFF1
08/03/2023321600157Open ↗
▸DOB NOWTR4 Test Report and Plot Diagram1
08/13/2026B00493594-I1Open ↗
▸DOB NOWTR4 Plot Diagram1
08/13/2026B00493594-I1Open ↗
▸Approvals, Objections & Sign-offs10
▸BISLETTERS - SUPPORTING DOCUMENTATION7
08/15/2023321600157Open ↗
08/15/2023321600157Open ↗
08/15/2023321600157Open ↗
Showing 3 of 7 on file for this type
▸BISSCHEDULE A - OCCUPANCY / USE3
05/02/2023321600157Open ↗
05/01/2023321600157Open ↗
04/15/2021321600157Open ↗
▸Cost, Insurance & Ownership3
▸BISPROJECT-SPECIFIC GL INSURANCE2
11/08/2021321600157Open ↗
07/14/2021322094149Open ↗
▸BISAcord 25 (Acord Certificate of Liability Insurance)1
07/14/2021322094149Open ↗
▸Filing & Intake Forms15
▸BISADDITIONAL INFORMATION11
08/15/2023321600157Open ↗
08/15/2023321600157Open ↗
08/03/2023321600157Open ↗
Showing 3 of 11 on file for this type
▸BISEFILING COVER SHEET2
05/01/2023322160558Open ↗
03/29/2021322094149Open ↗
▸BISEFILING JOB APPLICATION COVER SHEET1
04/21/2021340810144Open ↗
▸BISBPP: CHECKLIST IN LIEU OF PLANS-ALT31
04/21/2021340810144Open ↗
▸Other Documents10
▸BISPLOT DIAGRAM2
05/04/2023322160558Open ↗
04/19/2021321600157Open ↗
▸BISEXTERNAL FORMS - SUPPORTING DOCUMENTATION2
05/01/2023322160558Open ↗
05/01/2023322160558Open ↗
▸DOB NOWAdjoining Owners Notification2
08/13/2026B00493594-I1Open ↗
08/13/2026B00493594-S2Open ↗
▸BISSUSTAINABLE ROOF ZONE FORM1
05/28/2021321600157Open ↗
▸BISBPP: PHOTOS-SIGNED/SEALED BY APPLICANT1
07/20/2021340810144Open ↗
▸BISPROTECTION OF EXPOSED FOUNDATION INSULATION1
06/15/2023321600157Open ↗
▸BISBPP - SUPPORTING DOCUMENTATION1
04/21/2021340810144Open ↗