← Back
Primarily 1 family with 1 store or office
1515 WARING AVENUE
BRONX · Pelham Gardens · BIN 2052916
💬 Discuss this project
1965Year Built
2Stories
S1Building Class
R4AZoning
2,520 sfGross Floor Area
2Units
Primarily 1 family with 1 store or office · 2,850 sf lot · 0.88 FAR built · Flood zone X
Locations of Work
ArchitectureElectrical
Roof2p · 1 filing · 9 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
11/24/2021$700K—1515 WARING AVE INC. → Private party$278/sf building
12/14/2018$575K—Private party → 1515 WARING AVE INC$228/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
TOM PETERSEN ARCHITECT, LLC111/25/2025
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
SOLAR CONTRACTING LLCGeneral Contractor104/09/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
THOMAS PETERSEN ARCHITECT7854111/25/2025
Building Lifecycle
All (8)Filed (1)Permit Issued (1)Signed Off (1)Special Inspection (5)
06/22/2026
Signed off — Alteration
SCOPE OF WORK IS SOLELY FOR THE INSTALLATION OF THE SOLAR ELECTRONICGENERATING SYSTEM. ALL OTHER WORK IS NOT TO BE RELIED UPON AS BEINGAPPROVED AND/OR PERMITTED BY THE NYC DEPARTMENT OF BUILDINGS.*NO CHANGE TO USE, EGRESS OR OCCUPANCY.
X01321619-I1
01/12/2026
Permit issued — Solar
X01321619-I1-SL
11/25/2025
Filed — Alteration
SCOPE OF WORK IS SOLELY FOR THE INSTALLATION OF THE SOLAR ELECTRONICGENERATING SYSTEM. ALL OTHER WORK IS NOT TO BE RELIED UPON AS BEINGAPPROVED AND/OR PERMITTED BY THE NYC DEPARTMENT OF BUILDINGS.*NO CHANGE TO USE, EGRESS OR OCCUPANCY.
X01321619-I1
11/19/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
TOM PETERSEN
11/19/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
TOM PETERSEN
11/19/2025
Special inspection requirement — Energy Code Compliance Inspections
TOM PETERSEN
11/19/2025
Special inspection requirement — Final
TOM PETERSEN
11/19/2025
Special inspection requirement — Air barrier - visual inspection
TOM PETERSEN
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarSigned-offSOLAR CONTRACTING LLC01/12/2026
2 projects · most recent 05/12/2026
FiledStatusContractorScope
05/12/2026Pending PaymentSOLAR ELEC CONTRACTNG LLC3 meters, 1 new_meters
05/07/2026CompleteSOLAR ELEC CONTRACTNG LLC1 meters
1 project · most recent 11/25/2025
FiledStatusContractorScope
11/25/2025Signed-offSOLAR CONTRACTING LLC54 panels, 23.22 kw, 567.53 roof_area_sqft
▾Special Inspection Requirements (DOB NOW) — 5
DateRequirementInspectorRole
11/19/2025Fire-Resistant Penetrations and JointsTOM PETERSENspecial
11/19/2025Structural Stability – Alterations of existing buildingsTOM PETERSENspecial
11/19/2025Energy Code Compliance InspectionsTOM PETERSENprogress
11/19/2025FinalTOM PETERSENprogress
11/19/2025Air barrier - visual inspectionTOM PETERSENenergy_progress
▾Documents — 9 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/17/2026X01321619-I1Request digital key ↗
▸Seals & Professional Certifications6
▸DOB NOWProgress Inspector Seal & Signature3
08/23/2026X01321619-I1Open ↗
08/23/2026X01321619-I1Open ↗
08/23/2026X01321619-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
08/23/2026X01321619-I1Open ↗
08/23/2026X01321619-I1Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/13/2026X01321619-I1Open ↗
▸Environmental & Asbestos1
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/13/2026X01321619-I1Open ↗
▸Approvals, Objections & Sign-offs1
▸DOB NOWUtility Company Final Acceptance Letter1
08/17/2026X01321619-I1Open ↗