← Back
Two family converted from one family
152-16 134 AVENUE
QUEENS · BIN 4263192
💬 Discuss this project
1930Year Built
2Stories
B3Building Class
R3-1Zoning
980 sfGross Floor Area
2Units
Rent Stabilized2 Open Violations ▸FDNY Report ↗
Two family converted from one family · Owner of record: DC PROPERTIES NY LLC · 4,000 sf lot · 0.25 FAR built · Flood zone X500
Locations of Work
ArchitectureStructuralElectricalMechanicalPlumbing
Floor 215p · 1 filing · 20 docs
Floor 112p · 1 filing · 20 docs
Cellar19p · 1 filing · 20 docs
1 job · most recent 08/11/2025
Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
08/11/2025Permit IssuedNOVELTY CONSTRUCTION CORPAir Conditioning Systems
Cooling
Carrier Carrier ( MODEL No. 24ABB348A360) 48,000 BTU · Condensing Unit ×3
Comfort Aire COMFORT-AIRE ( MPDEL No. RSG1336S1M-1 ) 36,000 BTU · Condensing Unit ×3
1 job · most recent 08/11/2025
Gas Water/Sanitary
FiledStatusContractorScope
08/11/2025Permit IssuedROCK E SMALL PLBG&HTG INCGas, Water/Sanitary
1 job · most recent 05/15/2025
General Wiring
FiledStatusContractorScope
05/15/2025Permit IssuedSCOTT ELEC'L SERVICE, LLCGeneral Wiring
1 job · most recent 08/11/2025
Wood
FiledStatusContractorScope
08/11/2025Permit IssuedROCK E SMALL PLBG&HTG INCWood
1 job · most recent 08/11/2025
Fence
FiledStatusContractorScope
08/11/2025Permit IssuedROCK E SMALL PLBG&HTG INCFence
Building Lifecycle
All (72)Filed (5)Permit Issued (6)Violation (2)Inspection (5)Objection (24)Special Inspection (30)
02/06/2026
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
11/25/2025
Violation issued (HPD, open)
I
10/02/2025
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
10/02/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
10/02/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
09/17/2025
Special inspection requirement — Masonry
Nasir Khanzada
09/17/2025
Special inspection requirement — Concrete - Cast-In-Place
Nasir Khanzada
09/17/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Nasir Khanzada
09/17/2025
Special inspection requirement — Subgrade Inspections
Nasir Khanzada
09/17/2025
Special inspection requirement — Designated Seismic System
Nasir Khanzada
09/17/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
Nasir Khanzada
09/17/2025
Special inspection requirement — Mechanical Systems
Nasir Khanzada
09/17/2025
Special inspection requirement — Construction Utilizing CLT or SCL, Type IV
Nasir Khanzada
09/17/2025
Special inspection requirement — Subsurface Investigations (Borings/Test Pits)
Nasir Khanzada
09/17/2025
Special inspection requirement — Structural Wood Frame
Nasir Khanzada
09/17/2025
Special inspection requirement — Final
Nasir Khanzada
09/17/2025
Special inspection requirement — Energy Code Compliance Inspections
Nasir Khanzada
09/17/2025
Special inspection requirement — Fire-Resistance Rated Construction
Nasir Khanzada
09/17/2025
Special inspection requirement — Footing and Foundation
Nasir Khanzada
09/17/2025
Special inspection requirement — Interior lighting power
Nasir Khanzada
09/17/2025
Special inspection requirement — Air barrier - visual inspection
Nasir Khanzada
09/17/2025
Special inspection requirement — Permanent certificate
Nasir Khanzada
09/17/2025
Special inspection requirement — Insulation placement and R values
Nasir Khanzada
09/17/2025
Special inspection requirement — Fenestration air leakage
Nasir Khanzada
09/17/2025
Special inspection requirement — Maintenance information
Nasir Khanzada
09/17/2025
Special inspection requirement — Fenestration areas
Nasir Khanzada
09/17/2025
Special inspection requirement — Metering
Nasir Khanzada
09/17/2025
Special inspection requirement — Fenestration and door U-factor and product ratings
Nasir Khanzada
09/17/2025
Special inspection requirement — Protection of exposed foundation insulation
Nasir Khanzada
08/11/2025
Filed — Alteration
SITE FENCE FILING IN CONJUNCTION WITH ALT- 2FILING FOR RENOVATION OF EXISTING TWO-FAMILY DWELLING WITH HORIZONTAL AND VERTICAL EXTENSION.
Q01082526-P2
08/08/2025
Special inspection requirement — Construction Utilizing CLT or SCL, Type IV
Nasir Khanzada
08/08/2025
Special inspection requirement — Masonry
Nasir Khanzada
08/08/2025
Special inspection requirement — Mechanical Systems
Nasir Khanzada
08/08/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Nasir Khanzada
08/08/2025
Special inspection requirement — Subgrade Inspections
Nasir Khanzada
08/08/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
Nasir Khanzada
06/10/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
04/02/2025
Permit issued — Plumbing
Q01082526-S2-PL
03/27/2025
Filed — Alteration
SITE FENCE FILING IN CONJUNCTION WITH ALT- 2FILING FOR RENOVATION OF EXISTING TWO-FAMILY DWELLING WITH HORIZONTAL AND VERTICAL EXTENSION.
Q01082526-P1
03/13/2025
Permit issued — Mechanical Systems
Q01082526-I1-GC
03/13/2025
Permit issued — Structural
Q01082526-I1-MS
03/13/2025
Permit issued — Foundation
Q01082526-I1-ST
03/12/2025
Permit issued — Construction Fence
Q01082526-S1-FN
03/12/2025
Permit issued — Mechanical Systems
Q01082526-I1-FO-EA
12/05/2024
Violation issued (HPD, open)
I
10/22/2024
Objection resolved — Addressed
10/22/2024
Objection resolved — Addressed
10/22/2024
Objection resolved — Addressed
10/08/2024
Filed — Alteration
SITE FENCE FILING IN CONJUNCTION WITH ALT- 2FILING FOR RENOVATION OF EXISTING TWO-FAMILY DWELLING WITH HORIZONTAL AND VERTICAL EXTENSION.
Q01082526-S1
10/08/2024
Filed — Alteration
SITE FENCE FILING IN CONJUNCTION WITH ALT- 2FILING FOR RENOVATION OF EXISTING TWO-FAMILY DWELLING WITH HORIZONTAL AND VERTICAL EXTENSION.
Q01082526-S2
09/03/2024
Objection resolved — Addressed
08/30/2024
Objection raised — Scope
08/13/2024
Objection resolved — Addressed
08/13/2024
Objection resolved — Addressed
08/13/2024
Objection resolved — Addressed
08/13/2024
Objection resolved — Addressed
08/12/2024
Objection resolved — Addressed
08/12/2024
Objection resolved — Addressed
08/09/2024
Objection raised — Zoning
08/09/2024
Objection raised — Energy
Latest 60 of 72 events.
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
O BRIEN ST PROPERTIES103/22/2026
DC PROPERTIES NY LLC103/21/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
02/14/2018$475K—— → —$485/sf building
04/17/2014$220K—Private party → Private party$224/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
NASIR J, KHANZADA LLC508/11/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
NASIR J. KHANZADA LLC1003/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
NOVELTY CONSTRUCTION CORPGeneral Contractor1107/08/2026
SCOTT ELEC'L SERVICE, LLCElectrical103/22/2026
ROCK E SMALL PLBG&HTG INCPlumbing106/28/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
NASIR J. KHANZADA LLC1527708/11/2025
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedROCK E SMALL PLBG&HTG INC04/02/2025
DOB NOWMechanical SystemsPermit IssuedNOVELTY CONSTRUCTION CORP03/13/2025
DOB NOWStructuralPermit IssuedNOVELTY CONSTRUCTION CORP03/13/2025
DOB NOWFoundationPermit IssuedNOVELTY CONSTRUCTION CORP03/13/2025
DOB NOWConstruction FencePermit IssuedNOVELTY CONSTRUCTION CORP03/12/2025
DOB NOWMechanical SystemsPermit IssuedNOVELTY CONSTRUCTION CORP03/12/2025
▾Field Inspections (DOB CAP) — 5
DateTypeResultReport
02/06/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
10/02/2025Certified Gas-Gas-Piping-RoughingCertifiedView ↗
10/02/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
10/02/2025Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
06/10/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 54
DateRequirementInspectorRole
09/17/2025MasonryNasir Khanzadaspecial
09/17/2025Concrete - Cast-In-PlaceNasir Khanzadaspecial
09/17/2025Fire-Resistant Penetrations and JointsNasir Khanzadaspecial
09/17/2025Subgrade InspectionsNasir Khanzadaspecial
09/17/2025Designated Seismic SystemNasir Khanzadaspecial
09/17/2025Structural Stability – Alterations of existing buildingsNasir Khanzadaspecial
09/17/2025Mechanical SystemsNasir Khanzadaspecial
09/17/2025Construction Utilizing CLT or SCL, Type IVNasir Khanzadaspecial
09/17/2025Subsurface Investigations (Borings/Test Pits)Nasir Khanzadaspecial
09/17/2025Structural Wood FrameNasir Khanzadaprogress
09/17/2025FinalNasir Khanzadaprogress
09/17/2025Energy Code Compliance InspectionsNasir Khanzadaprogress
09/17/2025Fire-Resistance Rated ConstructionNasir Khanzadaprogress
09/17/2025Footing and FoundationNasir Khanzadaprogress
09/17/2025Interior lighting powerNasir Khanzadaenergy_progress
09/17/2025Air barrier - visual inspectionNasir Khanzadaenergy_progress
09/17/2025Permanent certificateNasir Khanzadaenergy_progress
09/17/2025Insulation placement and R valuesNasir Khanzadaenergy_progress
09/17/2025Fenestration air leakageNasir Khanzadaenergy_progress
09/17/2025Maintenance informationNasir Khanzadaenergy_progress
09/17/2025Fenestration areasNasir Khanzadaenergy_progress
09/17/2025MeteringNasir Khanzadaenergy_progress
09/17/2025Fenestration and door U-factor and product ratingsNasir Khanzadaenergy_progress
09/17/2025Protection of exposed foundation insulationNasir Khanzadaenergy_progress
08/08/2025Construction Utilizing CLT or SCL, Type IVNasir Khanzadaspecial
Latest 25 of 54.
▾Documents — 51 on file (BIS + DOB NOW)
▸Plans & Drawings5
▸DOB NOWPlans/Sketch5
08/21/2026Q01082526-P2Request digital key ↗
08/21/2026Q01082526-P1Request digital key ↗
08/21/2026Q01082526-S2Request digital key ↗
Showing 3 of 5 on file for this type
▸Zoning, Tax Lot & Property Records3
▸DOB NOWZD1: DOB Zoning Diagram3
08/13/2026Q01082526-P2Open ↗
08/13/2026Q01082526-I1Open ↗
08/13/2026Q01082526-P1Open ↗
▸Seals & Professional Certifications28
▸DOB NOWProgress Inspector Seal & Signature16
09/01/2026Q01082526-P2Open ↗
09/01/2026Q01082526-P2Open ↗
09/01/2026Q01082526-P2Open ↗
Showing 3 of 16 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature7
09/01/2026Q01082526-P2Open ↗
09/01/2026Q01082526-P2Open ↗
09/01/2026Q01082526-P2Open ↗
Showing 3 of 7 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature5
08/21/2026Q01082526-I1Open ↗
08/21/2026Q01082526-P2Open ↗
08/21/2026Q01082526-P1Open ↗
Showing 3 of 5 on file for this type
▸Inspections & Test Reports5
▸DOB NOWSOIL REPORT3
08/13/2026Q01082526-I1Open ↗
08/13/2026Q01082526-P1Open ↗
08/13/2026Q01082526-P2Open ↗
▸DOB NOWGeotechnical Report (BC 1803.6)1
08/13/2026Q01082526-I1Open ↗
▸DOB NOWTR4 Test Report and Plot Diagram1
08/13/2026Q01082526-I1Open ↗
▸Other Documents10
▸DOB NOWSite Survey: Initial3
08/13/2026Q01082526-P1Open ↗
08/13/2026Q01082526-I1Open ↗
08/13/2026Q01082526-P2Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone3
08/13/2026Q01082526-I1Open ↗
08/13/2026Q01082526-P2Open ↗
08/13/2026Q01082526-P1Open ↗
▸DOB NOWPlot Diagram3
08/13/2026Q01082526-P2Open ↗
08/13/2026Q01082526-P1Open ↗
08/13/2026Q01082526-I1Open ↗
▸DOB NOWAdjoining Owners Notification1
08/13/2026Q01082526-I1Open ↗