← Back
Office with commercial, 7-19 stories
152 WEST 36 STREET
MANHATTAN · BIN 1015233
💬 Discuss this project
1900Year Built
8Stories
O6Building Class
M1-9A/R12Zoning
51,853 sfGross Floor Area
49Units
LL97 Covered7 Open Violations 4 unresolved · 3 paperwork only ▸FISP: SWARMP
Office with commercial, 7-19 stories · Owner of record: 152 W 36 OWNER LLC · 5,925 sf lot · 8.75 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralElectricalMechanicalPlumbingFire ProtectionEquipmentGeneral
Permit Issued — active, not yet Signed-off
RoofUnder Construction75p · 4 filings · 20 docs
Floor 16Under Construction61p · 2 filings · 20 docs
Floor 15Under Construction62p · 2 filings · 20 docs
Floor 14Under Construction63p · 2 filings · 20 docs
Floor 13Under Construction62p · 2 filings · 20 docs
Floor 12Under Construction63p · 2 filings · 20 docs
Floor 11Under Construction67p · 2 filings · 20 docs
Floor 10Under Construction65p · 2 filings · 20 docs
Floor 9Under Construction63p · 2 filings · 20 docs
Floor 8Under Construction98p · 4 filings · 20 docs
Floor 7Under Construction97p · 4 filings · 20 docs
Floor 6Under Construction94p · 4 filings · 20 docs
Floor 5Under Construction97p · 4 filings · 20 docs
Floor 4Under Construction106p · 4 filings · 20 docs
Floor 3Under Construction106p · 4 filings · 20 docs
Floor 2Under Construction107p · 4 filings · 20 docs
Floor 1Under Construction109p · 4 filings · 20 docs
CellarUnder Construction129p · 5 filings · 20 docs
1 job · most recent 07/07/2026
Heating and Air Conditioning Systems Heating Systems
FiledStatusContractorScopeMake / Model / Capacity
07/07/2026Permit IssuedJRM CONSTRUCTION MGMT LLCHeating and Air Conditioning Systems, Heating Systems
Heat / Cool
Mitsubishi Electric TUHYE0723AN40A(N/B) 6 tons · Vrf Outdoor ×40
NTXMSM48A182BA 4 tons · Condensing Unit ×21
TRUZA0241HA70NA 2 tons · Condensing Unit ×4
NTXMSM36A142BA 3 tons · Condensing Unit ×2
Heating
Trane ×5
2 jobs · most recent 07/07/2026
Sprinkler System
FiledStatusContractorScope
07/07/2026Permit IssuedKG SPRINKLER CORPSprinkler System
11/12/2025Permit IssuedKG SPRINKLER CORP2 outlets
2 jobs · most recent 07/07/2026
Storm Water/Sanitary
FiledStatusContractorScope
07/07/2026Permit IssuedDONATO PLUMBING, INCStorm, Water/Sanitary
11/12/2025———
5 jobs · most recent 05/28/2026
General Wiring
FiledStatusContractorScope
05/28/2026Permit IssuedCOGEN ELEC'L SERVICES,INCGeneral Wiring
03/22/2026Permit IssuedDENALI ELECTRIC CORP—
12/20/2024Permit IssuedCOGEN ELEC'L SERVICES,INC—
12/04/2024CompletePOLARIS ELEC'L CONST CORP—
11/13/2024Permit IssuedCOGEN ELEC'L SERVICES,INC—
2 jobs · most recent 08/12/2025
Steel Concrete
FiledStatusContractorScope
08/12/2025Permit IssuedTITAN INDUSTRIAL SVC CORPSteel, Concrete
08/12/2025Permit IssuedJRM CONSTRUCTION MGMT LLC2 scope_items
4 jobs · most recent 04/22/2026
Scaffold Fence Sidewalk Shed
FiledStatusContractorScope
04/22/2026Signed-offBPRT CONSTRUCTION OF NYScaffold
05/23/2025Permit IssuedSKYLINE SCAFFOLDING GROUPFence
05/07/2025Signed-offSKYLINE SCAFFOLDING GROUPScaffold
04/25/2025Permit IssuedSKYLINE SCAFFOLDING GROUPSidewalk Shed
1 job · most recent 06/23/2026
Suspended Scaffold (SC)
FiledStatusContractorScope
06/23/2026Permit IssuedA EAGLE CONSTRUCTION CORPSuspended Scaffold (SC)
Building Lifecycle
All (272)Filed (58)Permit Issued (57)Signed Off (11)Facade (FISP) (12)Violation (57)Inspection (31)Objection (16)Special Inspection (30)
09/29/2026
Permit issued — Structural
M01003416-S3-ST
09/18/2026
Permit issued — Curb Cut
M01021448-I1-CC
08/14/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
08/10/2026
Permit issued — General Construction
M01003551-I1-GC
08/07/2026
Permit issued — Structural
M01003551-S6-ST
08/05/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
08/04/2026
Special inspection requirement — HVAC-R and service water heating equipment
Ari Kamo
08/04/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Ari Kamo
08/04/2026
Special inspection requirement — Maintenance information
Ari Kamo
08/04/2026
Special inspection requirement — Energy Code Compliance Inspections
Ari Kamo
08/04/2026
Special inspection requirement — HVAC-R and service water heating system controls
Ari Kamo
08/04/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
Ari Kamo
07/28/2026
Signed off — Alteration
INSTALLATION OF TEMPORARY PIPE SCAFFOLD AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
M01389212-I1
07/27/2026
Signed off — Alteration
INSTALLATION AND USE OF TEMPORARY LOADING PLATFORM. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
M01346542-I1
07/27/2026
Signed off — Alteration
INSTALLATION AND USE OF TEMPORARY GANTRY BEAM. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
M01250227-I1
07/27/2026
Signed off — Alteration
Installation of a temporary needle beam per plan submitted. Work shall comply with 2022 building codes chapter 33. No change in use, egress and/or occupancy with this application.
M01150956-I1
07/27/2026
Signed off — Alteration
M01323670-I1
07/23/2026
Signed off — Alteration
M01135630-I1
07/22/2026
Permit issued — Sprinklers
M01003551-S9-EW-SP
07/22/2026
Permit issued — Standpipe
M01003551-S9-EW-SD
07/22/2026
Violation issued (ECB, open)
Construction
07/22/2026
Violation issued (ECB, closed)
Unknown
07/22/2026
Violation issued (ECB, open)
Construction
07/22/2026
Violation issued (ECB, open)
Construction
07/21/2026
Permit issued — Plumbing
M01003551-S8-PL
07/20/2026
Permit issued — Mechanical Systems
M01003551-S7-MS
07/08/2026
Special inspection requirement — Alternative Materials - OTCR Buildings Bulletin Number
Jacky Philibert
07/08/2026
Special inspection requirement — Post-installed Anchors
Jacky Philibert
07/07/2026
Filed — Alteration CO
INSTALLATION OF PL FIXTURES & RELATED PIPING AS SHOWN ON PLAN FOR ENLARGEMENT OF EXISTING 8-STORY BLDG TO 16 STORY BLDG. APP FILED IN CONJ/W M01003551-I1 (GC), M01004304-I1 (FO),M01003551-S6 (ST), M01003551-S7 (MS), M01003551-S9 (SP/SD), M01003551-S10(BE)
M01003551-P5
07/02/2026
Inspection — Certified Storm Drainage-ST-Piping-Roughing
Certified
View inspection ↗
07/02/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
07/01/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Ari Kamo
07/01/2026
Special inspection requirement — Maintenance information
Ari Kamo
07/01/2026
Special inspection requirement — Energy Code Compliance Inspections
Ari Kamo
07/01/2026
Special inspection requirement — HVAC-R and service water heating system controls
Ari Kamo
07/01/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
Ari Kamo
07/01/2026
Special inspection requirement — HVAC-R and service water heating equipment
Ari Kamo
06/23/2026
Filed — Alteration
Installation of suspended scaffold for facade work or inspection.
M01388029-P1
06/23/2026
Special inspection requirement — Post-installed Anchors
Jacky Philibert
06/23/2026
Special inspection requirement — Alternative Materials - OTCR Buildings Bulletin Number
Jacky Philibert
06/11/2026
Inspection — Fail-Final PL - Up to 9 Requested Floors
Fail
View inspection ↗
06/08/2026
Signed off — Alteration
DEMOLITION AND REMOVAL OF EXISTING BOILER, FUEL OIL STORAGE TANK, PIPING, RADIATORS, AIR HANLDERS, ASSOCIATED CONDENSING UNITS, EXHAUST FANS, DUCTWORK, AIR DEVICES, WINDOW AC UNITS, AND ASSOCIATED APPURTENANCES AS SHOWN ON PLANS.
M01001558-S2
06/05/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
05/26/2026
Signed off — Alteration
DEMOLITION AND REMOVAL OF EXISTING BOILER, FUEL OIL STORAGE TANK, PIPING, RADIATORS, AIR HANLDERS, ASSOCIATED CONDENSING UNITS, EXHAUST FANS, DUCTWORK, AIR DEVICES, WINDOW AC UNITS, AND ASSOCIATED APPURTENANCES AS SHOWN ON PLANS.
M01001558-I1
05/22/2026
Signed off — Alteration
DEMOLITION AND REMOVAL OF EXISTING BOILER, FUEL OIL STORAGE TANK, PIPING, RADIATORS, AIR HANLDERS, ASSOCIATED CONDENSING UNITS, EXHAUST FANS, DUCTWORK, AIR DEVICES, WINDOW AC UNITS, AND ASSOCIATED APPURTENANCES AS SHOWN ON PLANS.
M01001558-S1
05/14/2026
Permit issued — Construction Fence
M01118116-I1-FN
05/14/2026
Permit issued — Protection and Mechanical Methods
M01118097-I1-PMM
05/13/2026
Signed off — Alteration
Installation of a temporarily supported scaffold per plan submitted. Work shall comply with 2022 building codes chapter 33. No change in use, egress and/or occupancy with this application.
M01118110-I1
05/13/2026
Signed off — Alteration
Installation of a temporarily supported scaffold per plan submitted. Work shall comply with 2022 building codes chapter 33. No change in use, egress and/or occupancy with this application.
M01150965-I1
05/13/2026
Permit issued — Protection and Mechanical Methods
M01157133-I1-PMM
05/11/2026
Filed — Alteration
DEMOLITION AND REMOVAL OF EXISTING BOILER, FUEL OIL STORAGE TANK, PIPING, RADIATORS, AIR HANLDERS, ASSOCIATED CONDENSING UNITS, EXHAUST FANS, DUCTWORK, AIR DEVICES, WINDOW AC UNITS, AND ASSOCIATED APPURTENANCES AS SHOWN ON PLANS.
M01001558-P3
05/08/2026
Filed — Alteration
M01157133-P3
05/08/2026
Permit issued — Suspended Scaffold
M01388029-I1-SC
05/06/2026
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
04/29/2026
Inspection — Fail-Final General Construction Non-Directive 14
Fail
View inspection ↗
04/27/2026
Permit issued — Supported Scaffold
M01389212-I1-SF
04/23/2026
Filed — Alteration
Installation of suspended scaffold for facade work or inspection.
M01388029-I1
04/22/2026
Filed — Alteration
INSTALLATION OF TEMPORARY PIPE SCAFFOLD AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
M01389212-I1
04/17/2026
Inspection — Certified StandPipe - SD - Alarm Sys 64/09 - Finish
Certified
View inspection ↗
04/17/2026
Inspection — Certified StandPipe - SD - Hydrostatic 63/09 Test (Initial 75 Feet)
Certified
View inspection ↗
Latest 60 of 272 events.
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
MEQUITY COMPANIES6809/19/2026
SKYLINE SCAFFOLDING GROUP3708/29/2026
GLENCO CONTRACTING GROUP INC.1406/28/2026
152 W 36 OWNER LLC103/22/2026
HADJI BABA PROPERTIES COR303/22/2026
JRM CONSTRUCTION MGMT203/22/2026
HODJI BABA PROPERTIES COR103/22/2026
FALCON PROPERTIES1203/22/2026
DSLCOM PROPERTIES103/22/2026
FALCON PROPERTY203/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
09/09/2024$23.8M—— → —$459/sf building
▾Design Consultants (Architect / Engineer of Record)
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
GEORGE E BERGER ASS4603/21/2026
Rigid Structural Design, LLC3203/21/2026
A1 EXPEDITING SERVICE603/21/2026
LOMBARDO PROFESSIONAL ENGINEERING403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
SKYLINE SCAFFOLDING GROUPGeneral Contractor2207/08/2026
JRM CONSTRUCTION MGMT LLCGeneral Contractor1909/19/2026
KG SPRINKLER CORPFire Protection707/23/2026
TITAN INDUSTRIAL SVC CORPGeneral Contractor704/09/2026
GLENCO CONTRACTING GROUPGeneral Contractor606/28/2026
DONATO PLUMBING, INCPlumbing407/22/2026
JOE MIDDLETONElectrical203/21/2026
MYERS, JOSEPHElectrical103/21/2026
BPRT CONSTRUCTION OF NYGeneral Contractor107/01/2026
JACKUS, STEVEElectrical103/21/2026
HINKE, WILLIAMElectrical103/21/2026
DEDOS, RAULElectrical103/21/2026
PETER AMABILEElectrical103/21/2026
A-ULTIMATE EL. CON.&MGMT.Electrical103/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
AK ENGINEERING PC6782607/07/2026
PHILIBERT ENGINEERING, PC223206/23/2026
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWStructuralPermit IssuedTITAN INDUSTRIAL SVC CORP09/29/2026
DOB NOWCurb CutPermit IssuedJRM CONSTRUCTION MGMT LLC09/18/2026
DOB NOWGeneral ConstructionPermit IssuedJRM CONSTRUCTION MGMT LLC08/10/2026
DOB NOWStructuralPermit IssuedJRM CONSTRUCTION MGMT LLC08/07/2026
DOB NOWSprinklersPermit IssuedKG SPRINKLER CORP07/22/2026
DOB NOWStandpipePermit IssuedKG SPRINKLER CORP07/22/2026
DOB NOWPlumbingPermit IssuedDONATO PLUMBING, INC07/21/2026
DOB NOWMechanical SystemsPermit IssuedJRM CONSTRUCTION MGMT LLC07/20/2026
DOB NOWConstruction FencePermit IssuedSKYLINE SCAFFOLDING GROUP05/14/2026
DOB NOWProtection and Mechanical MethodsPermit IssuedSKYLINE SCAFFOLDING GROUP05/14/2026
DOB NOWProtection and Mechanical MethodsPermit IssuedSKYLINE SCAFFOLDING GROUP05/13/2026
DOB NOWSuspended ScaffoldPermit IssuedA EAGLE CONSTRUCTION CORP05/08/2026
DOB NOWSupported ScaffoldSigned-offBPRT CONSTRUCTION OF NY04/27/2026
DOB NOWGeneral ConstructionPermit IssuedJRM CONSTRUCTION MGMT LLC04/01/2026
DOB NOWFoundationPermit IssuedJRM CONSTRUCTION MGMT LLC03/31/2026
DOB NOWSupported ScaffoldSigned-offSKYLINE SCAFFOLDING GROUP02/02/2026
DOB NOWProtection and Mechanical MethodsSigned-offGLENCO CONTRACTING GROUP01/21/2026
DOB NOWSupported ScaffoldSigned-offSKYLINE SCAFFOLDING GROUP01/20/2026
DOB NOWStructuralPermit IssuedTITAN INDUSTRIAL SVC CORP12/15/2025
DOB NOWStructuralPermit IssuedJRM CONSTRUCTION MGMT LLC12/09/2025
DOB NOWProtection and Mechanical MethodsSigned-offGLENCO CONTRACTING GROUP11/24/2025
DOB NOWSidewalk ShedPermit IssuedSKYLINE SCAFFOLDING GROUP11/06/2025
DOB NOWConstruction FencePermit IssuedSKYLINE SCAFFOLDING GROUP11/05/2025
DOB NOWProtection and Mechanical MethodsPermit IssuedSKYLINE SCAFFOLDING GROUP11/05/2025
DOB NOWPlumbingSigned-offDONATO PLUMBING, INC10/20/2025
DOB NOWStandpipePermit IssuedH M SPRINKLER INC10/20/2025
DOB NOWBoiler EquipmentPermit IssuedSTUART N SCHWARTZ10/15/2025
DOB NOWStandpipePermit IssuedH M SPRINKLER INC10/10/2025
DOB NOWMechanical SystemsSigned-offJRM CONSTRUCTION MGMT LLC10/06/2025
DOB NOWGeneral ConstructionSigned-offJRM CONSTRUCTION MGMT LLC10/06/2025
DOB NOWGeneral ConstructionPermit IssuedJRM CONSTRUCTION MGMT LLC09/30/2025
DOB NOWStandpipePermit IssuedH M SPRINKLER INC07/22/2025
DOB NOWPlumbingPermit IssuedDONATO PLUMBING, INC07/22/2025
DOB NOWSprinklersPermit IssuedH M SPRINKLER INC07/22/2025
DOB NOWProtection and Mechanical MethodsSigned-offGLENCO CONTRACTING GROUP07/21/2025
DOB NOWProtection and Mechanical MethodsSigned-offGLENCO CONTRACTING GROUP07/08/2025
DOB NOWStructuralPermit IssuedJRM CONSTRUCTION MGMT LLC06/24/2025
DOB NOWMechanical SystemsPermit IssuedJRM CONSTRUCTION MGMT LLC06/10/2025
DOB NOWProtection and Mechanical MethodsSigned-offTITAN INDUSTRIAL SVC CORP06/10/2025
DOB NOWGeneral ConstructionPermit IssuedJRM CONSTRUCTION MGMT LLC06/09/2025
+ 47 more permits on file
▾Field Inspections (DOB CAP) — 31
DateTypeResultReport
08/14/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
08/05/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
07/02/2026Certified Storm Drainage-ST-Piping-RoughingCertifiedView ↗
07/02/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
06/11/2026Fail-Final PL - Up to 9 Requested FloorsFailView ↗
06/05/2026Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
05/06/2026Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
04/29/2026Fail-Final General Construction Non-Directive 14FailView ↗
04/17/2026Certified StandPipe - SD - Alarm Sys 64/09 - FinishCertifiedView ↗
04/17/2026Certified StandPipe - SD - Hydrostatic 63/09 Test (Initial 75 Feet)CertifiedView ↗
03/26/2026Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
03/24/2026Pass-Final PL - Up to 9 Requested FloorsPassView ↗
03/20/2026Certified Storm Drainage-ST-Piping-RoughingCertifiedView ↗
03/20/2026Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
03/20/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
03/20/2026Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
03/19/2026Fail-Final General Construction Non-Directive 14FailView ↗
03/10/2026Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
03/10/2026Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
02/10/2026Fail-Final PL - Up to 3 Requested FloorsFailView ↗
09/10/2025Certified Gas-Gas-Piping-RoughingCertifiedView ↗
09/10/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
03/10/2025Certified Storm Drainage-ST-Piping-RoughingCertifiedView ↗
01/08/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
10/16/2024Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
Latest 25 of 31.
▾Special Inspection Requirements (DOB NOW) — 142
DateRequirementInspectorRole
08/04/2026HVAC-R and service water heating system controlsAri Kamoenergy_progress
08/04/2026HVAC-R and service water heating equipmentAri Kamoenergy_progress
08/04/2026Fire-Resistant Penetrations and JointsAri Kamospecial
08/04/2026Energy Code Compliance InspectionsAri Kamoprogress
08/04/2026HVAC-R and service water piping design and insulationAri Kamoenergy_progress
08/04/2026Maintenance informationAri Kamoenergy_progress
07/08/2026Post-installed AnchorsJacky Philibertspecial
07/08/2026Alternative Materials - OTCR Buildings Bulletin NumberJacky Philibertspecial
07/01/2026Maintenance informationAri Kamoenergy_progress
07/01/2026HVAC-R and service water heating system controlsAri Kamoenergy_progress
07/01/2026HVAC-R and service water heating equipmentAri Kamoenergy_progress
07/01/2026HVAC-R and service water piping design and insulationAri Kamoenergy_progress
07/01/2026Fire-Resistant Penetrations and JointsAri Kamospecial
07/01/2026Energy Code Compliance InspectionsAri Kamoprogress
06/23/2026Post-installed AnchorsJacky Philibertspecial
06/23/2026Alternative Materials - OTCR Buildings Bulletin NumberJacky Philibertspecial
10/22/2025Standpipe SystemsAri Kamospecial
10/22/2025Fire-Resistant Penetrations and JointsAri Kamospecial
09/26/2025Electrical motors and elevatorsAri Kamoenergy_progress
09/26/2025Combustible Exterior Wall CoveringsAri Kamospecial
09/26/2025Fire-Resistant Penetrations and JointsAri Kamospecial
09/26/2025Structural Stability – Alterations of existing buildingsAri Kamospecial
09/26/2025Sprayed fire-resistant materialsAri Kamospecial
09/26/2025Luminous Exit Path MarkingsAri Kamospecial
09/26/2025Fire-Resistance Rated ConstructionAri Kamoprogress
Latest 25 of 142.
▾Documents — 456 on file (BIS + DOB NOW)
▸Plans & Drawings59
▸DOB NOWPlans/Sketch59
08/27/2026M01003551-P5Contact architect ↗
08/27/2026M01003551-I1Contact architect ↗
08/27/2026M01003551-S6Contact architect ↗
Showing 3 of 59 on file for this type
▸Applications & Permits74
▸BISPLAN / WORK APPROVAL APPLICATION49
02/04/2026140672341Open ↗
07/29/2025140327536Open ↗
07/23/2025140327536Open ↗
Showing 3 of 49 on file for this type
▸BISWORK PERMIT APPLICATION23
11/13/2020123080940Open ↗
08/02/2019123080940Open ↗
06/20/2019123080940Open ↗
Showing 3 of 23 on file for this type
▸BISPLAN - WORK & PERMITS - SUPPPORTING DOCUMENTATION1
09/23/2024141025575Open ↗
▸BISBPP-5 - Authorization to the Department of Transportation1
09/23/2024141025575Open ↗
▸Zoning, Tax Lot & Property Records6
▸DOB NOWZD1: DOB Zoning Diagram3
08/27/2026M01003551-P6Open ↗
08/13/2026M01003551-I1Open ↗
Showing 2 of 3 on file for this type
▸DOB NOWZoning Exhibit form (1-5)3
08/27/2026M01003551-P6Open ↗
08/13/2026M01003551-I1Open ↗
08/13/2026M01003551-P1Open ↗
▸Seals & Professional Certifications147
▸DOB NOWDPL-1: Design Professional Seal & Signature57
08/27/2026M01003551-P5Open ↗
08/27/2026M01003551-I1Open ↗
08/27/2026M01003551-S6Open ↗
Showing 3 of 57 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature32
09/22/2026M01003551-P4Open ↗
09/14/2026M01388029-I1Open ↗
09/14/2026M01388029-I1Open ↗
Showing 3 of 32 on file for this type
▸DOB NOWProgress Inspector Seal & Signature27
09/01/2026M01003551-P1Open ↗
09/01/2026M01003551-P1Open ↗
09/01/2026M01003551-P1Open ↗
Showing 3 of 27 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION13
10/23/2018123518602Open ↗
05/04/2017123080940Open ↗
02/18/2015122283037Open ↗
Showing 3 of 13 on file for this type
▸BISPROFESSIONAL CERTIFIED CHECKLIST5
07/29/2025140327536Open ↗
05/04/2017123080940Open ↗
06/04/2013121638638Open ↗
Showing 3 of 5 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM3
06/04/2013121638638Open ↗
05/20/2013121622789Open ↗
06/05/2012121055240Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY3
09/23/2024141025575Open ↗
07/22/2017140672341Open ↗
04/12/2015140327536Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT3
07/22/2017140672341Open ↗
05/04/2017123080940Open ↗
04/12/2015140327536Open ↗
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION2
07/22/2017140672341Open ↗
04/12/2015140327536Open ↗
▸BISAPPLICANT OWNER SIGNATURE1
09/23/2024141025575Open ↗
▸BISPC FULL REPORT1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸Trade Schedules & Equipment21
▸BISSCHEDULE B - PLUMBING7
03/10/2021123080940Open ↗
04/12/2015140327536Open ↗
05/20/2013121622789Open ↗
Showing 3 of 7 on file for this type
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE6
01/28/2019123080940Open ↗
12/26/2018123518602Open ↗
10/23/2018123518602Open ↗
Showing 3 of 6 on file for this type
▸BISSELF-CERT PLUMBING NOTICE3
06/04/2015140327536Open ↗
08/24/2012121055240Open ↗
07/18/2012121055240Open ↗
▸BISFA - FDNY APPROVAL : FD-FAA2
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 2 on file for this type
▸BISSPRINKLER INSP REPORT : FP-851
01/08/2019123518602Open ↗
▸BISSCHEDULE C - HEATING & COMBUSTION EQUIPMENT1
07/22/2017140672341Open ↗
▸BISSCHEDULE C - HEATING & COMBUSTION EQUIPMENT1
12/01/2022140672341Open ↗
▸Safety & Tenant Protection7
▸DOB NOWStreet Tree Checklist3
08/27/2026M01003551-P6Open ↗
08/13/2026M01003551-P1Open ↗
08/13/2026M01003551-I1Open ↗
▸BISSTREET TREES: RECEIPT OF STREET TREES SITE PLAN1
09/23/2024141025575Open ↗
▸BISSTREET TREES SITE PLAN1
09/23/2024141025575Open ↗
▸BISBPP: STREET TREES SITE PLAN1
10/07/2024141025575Open ↗
▸DOB NOWParks Department Acknowledgment Letter for Street Trees Plan1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸Environmental & Asbestos32
▸DOB NOWDEP ACP-5: Asbestos Assessment Report15
08/26/2026M01004301-S1Open ↗
08/22/2026M01004304-I1Open ↗
08/22/2026M01003416-S4Open ↗
Showing 3 of 15 on file for this type
▸BISASBESTOS: CERTIFICATION (DEP ACP5)7
10/23/2018123518602Open ↗
06/29/2018123374491Open ↗
05/04/2017123080940Open ↗
Showing 3 of 7 on file for this type
▸DOB NOWDEP ACP-20/ACP-21: Asbestos Project Conditional Completion Form/Asbestos Project Completion Form7
08/27/2026M01003551-I1Open ↗
08/27/2026M01003551-S6Open ↗
08/27/2026M01003551-S7Open ↗
Showing 3 of 7 on file for this type
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'3
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 3 on file for this type
▸Energy Compliance17
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS7
10/23/2018123518602Open ↗
09/12/2017123080940Open ↗
09/12/2017140672341Open ↗
Showing 3 of 7 on file for this type
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY3
07/22/2025140327536Open ↗
07/22/2017140672341Open ↗
04/12/2015140327536Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY FOR ENERGY CODE PROGRESS INSPECTIONS2
07/22/2017140672341Open ↗
04/12/2015140327536Open ↗
▸BISTECHNICAL REPORT: ENERGY2
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 2 on file for this type
▸BISTR8: Energy Code Progress Inspections1
05/20/2013121622789Open ↗
▸BISAS-BUILT ENERGY ANALYSIS (EN2)1
08/18/2025140327536Open ↗
▸BISNYCECC ANALYSIS1
04/12/2015140327536Open ↗
▸Inspections & Test Reports7
▸BISTECHNICAL REPORT: RESPONSIBILITY3
07/22/2025140327536Open ↗
07/22/2017140672341Open ↗
04/12/2015140327536Open ↗
▸DOB NOWSOIL REPORT2
08/22/2026M01004304-I1Open ↗
Showing 1 of 2 on file for this type
▸BISHYDRO FLOW TEST LETTER1
01/08/2019123518602Open ↗
▸DOB NOWTR4 Test Report and Plot Diagram1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸Approvals, Objections & Sign-offs17
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST7
08/20/2025140327536Open ↗
04/22/2025121638638Open ↗
04/22/2025103277080Open ↗
Showing 3 of 7 on file for this type
▸BISADMINISTRATIVE OBJECTIONS6
06/04/2013121638638Open ↗
05/20/2013121622789Open ↗
06/07/2012121101039Open ↗
Showing 3 of 6 on file for this type
▸BISLETTERS - SUPPORTING DOCUMENTATION2
07/29/2025140327536Open ↗
Showing 1 of 2 on file for this type
▸BISSUPERSEDING LETTER1
11/13/2020123080940Open ↗
▸BISFINAL1
08/18/2025140327536Open ↗
▸Cost, Insurance & Ownership15
▸BISCOST AFFIDAVIT14
10/23/2018123518602Open ↗
06/29/2018123374491Open ↗
07/22/2017140672341Open ↗
Showing 3 of 14 on file for this type
▸BISCOST AFFIDAVIT (FINAL): PW31
08/12/2025140327536Open ↗
▸Filing & Intake Forms32
▸BISADDITIONAL INFORMATION15
07/29/2025140327536Open ↗
09/23/2024141025575Open ↗
09/05/2023123080940Open ↗
Showing 3 of 15 on file for this type
▸BISEFILING COVER SHEET9
10/23/2018123518602Open ↗
06/29/2018123374491Open ↗
05/04/2017123080940Open ↗
Showing 3 of 9 on file for this type
▸BISBOROUGH INTAKE FORM5
11/13/2020123080940Open ↗
08/14/2018140672341Open ↗
08/14/2018123080940Open ↗
Showing 3 of 5 on file for this type
▸BISEFILING JOB APPLICATION COVER SHEET3
09/23/2024141025575Open ↗
07/22/2017140672341Open ↗
04/12/2015140327536Open ↗
▸Other Documents22
▸DOB NOWPlot Diagram5
08/27/2026M01003551-P6Open ↗
08/22/2026M01004304-I1Open ↗
08/13/2026M01004304-P1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWSite Survey: Initial3
08/27/2026M01003551-P6Open ↗
08/13/2026M01003551-P1Open ↗
08/13/2026M01003551-I1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone3
08/27/2026M01003551-P6Open ↗
Showing 1 of 3 on file for this type
▸DOB NOWProperty Ownership Certification3
08/27/2026M01003551-P6Open ↗
08/27/2026M01003551-I1Open ↗
08/27/2026M01003551-P1Open ↗
▸BISBPP - SUPPORTING DOCUMENTATION2
09/23/2024141025575Open ↗
09/23/2024141025575Open ↗
▸BISSupporting Document: Fee Exempt2
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 2 on file for this type
▸DOB NOWManufacturer's Specifications2
08/17/2026M01388029-P1Open ↗
08/17/2026M01388029-I1Open ↗
▸DOB NOWCalculations2
08/17/2026M01388029-P1Open ↗
08/17/2026M01388029-I1Open ↗