← Back
Three families
1528 76 STREET
BROOKLYN · Bensonhurst · BIN 3160726
💬 Discuss this project
1910Year Built
2.75Stories
C0Building Class
R4Zoning
3,085 sfGross Floor Area
3Units
Rent Stabilized16 Open Violations ▸FDNY Report ↗
Three families · 4,000 sf lot · 0.77 FAR built · Flood zone X
Locations of Work
ArchitectureMechanical
Permit Issued — active, not yet Signed-off
Floor 3Under Construction3p · 1 filing · 16 docs
Floor 2Under Construction1p · 1 filing · 16 docs
Floor 1Under Construction1p · 1 filing · 16 docs
CellarUnder Construction4p · 1 filing · 16 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
INNOSPARK DESIGN509/13/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
12/23/2025$2.0M—Private party → A & H LUCKY FISH LLC$648/sf building
05/16/2016$936K—— → —$303/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
AARON MCDONALD ARCHITECT204/30/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
BUILDWISE CONSTRUCTION GRGeneral Contractor107/08/2026
WELLDONE INSPECTIONS INCGeneral Contractor104/09/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
AARON MCDONALD ARCHITECT5118103/13/2026
Building Lifecycle
All (38)Filed (2)Permit Issued (2)Violation (16)Inspection (4)Special Inspection (14)
05/05/2026
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
05/04/2026
Permit issued — Construction Fence
B01371164-S2-FN
05/01/2026
Violation issued (HPD, open)
A
04/30/2026
Filed — Alteration
INTERIOR RENOVATION OF EXISTING 3-FAMILY BUILDING ON CELLAR, 1ST, 2ND AND 3RD FLOOR. GENERAL CONSTRUCTION AND MECHANICAL WORK AS PER PLAN. NO CHANGE IN EGRESS, USE OR OCCUPANCY.
B01371164-S2
03/16/2026
Permit issued — General Construction
B01371164-I1-GC-CX
03/13/2026
Filed — Alteration
INTERIOR RENOVATION OF EXISTING 3-FAMILY BUILDING ON CELLAR, 1ST, 2ND AND 3RD FLOOR. GENERAL CONSTRUCTION AND MECHANICAL WORK AS PER PLAN. NO CHANGE IN EGRESS, USE OR OCCUPANCY.
B01371164-I1
03/12/2026
Special inspection requirement — Mechanical Systems
Aaron McDonald
03/12/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Aaron McDonald
03/12/2026
Special inspection requirement — Final
Aaron McDonald
03/12/2026
Special inspection requirement — Energy Code Compliance Inspections
Aaron McDonald
03/12/2026
Special inspection requirement — Fire-Resistance Rated Construction
Aaron McDonald
03/12/2026
Special inspection requirement — Fenestration and door U-factor and product ratings
Aaron McDonald
03/12/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
Aaron McDonald
03/12/2026
Special inspection requirement — HVAC-R and service water heating equipment
Aaron McDonald
03/12/2026
Special inspection requirement — Fenestration areas
Aaron McDonald
03/12/2026
Special inspection requirement — Air barrier - visual inspection
Aaron McDonald
03/12/2026
Special inspection requirement — Interior lighting power
Aaron McDonald
03/12/2026
Special inspection requirement — HVAC-R and service water heating system controls
Aaron McDonald
03/12/2026
Special inspection requirement — Insulation placement and R values
Aaron McDonald
03/12/2026
Special inspection requirement — Fenestration air leakage
Aaron McDonald
11/20/2025
Violation issued (HPD, open)
I
10/03/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
10/01/2025
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
09/30/2025
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
06/06/2025
Violation issued (HPD, open)
A
11/29/2024
Violation issued (HPD, open)
I
04/08/2024
Violation issued (HPD, open)
A
11/21/2023
Violation issued (HPD, open)
I
03/21/2023
Violation issued (HPD, open)
A
11/10/2022
Violation issued (HPD, open)
I
02/22/2022
Violation issued (HPD, open)
I
02/22/2022
Violation issued (HPD, open)
A
04/06/2021
Violation issued (HPD, open)
A
04/06/2021
Violation issued (HPD, open)
I
10/29/2019
Violation issued (HPD, open)
I
10/15/2018
Violation issued (HPD, open)
I
11/17/2017
Violation issued (HPD, open)
I
11/03/2016
Violation issued (HPD, open)
I
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWConstruction FencePermit IssuedBUILDWISE CONSTRUCTION GR05/04/2026
DOB NOWGeneral ConstructionPermit IssuedWELLDONE INSPECTIONS INC03/16/2026
1 project · most recent 04/30/2026
Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
04/30/2026Permit IssuedBUILDWISE CONSTRUCTION GRAir Conditioning Systems
Cooling
Mitsubishi Electric MUZ-GL18NA-U1 21,600 BTU · Condensing Unit ×2
MUZ-GL09NA 10,900 BTU · Condensing Unit ×1
1 project · most recent 01/02/2026
General Wiring
FiledStatusContractorScope
01/02/2026Permit IssuedJ Y ELECTRIC INCGeneral Wiring
1 project · most recent 04/30/2026
Fence
FiledStatusContractorScope
04/30/2026Permit IssuedBUILDWISE CONSTRUCTION GRFence
▾Field Inspections (DOB CAP) — 4
DateTypeResultReport
05/05/2026Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
10/03/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
10/01/2025Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
09/30/2025Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 14
DateRequirementInspectorRole
03/12/2026Mechanical SystemsAaron McDonaldspecial
03/12/2026Fire-Resistant Penetrations and JointsAaron McDonaldspecial
03/12/2026FinalAaron McDonaldprogress
03/12/2026Energy Code Compliance InspectionsAaron McDonaldprogress
03/12/2026Fire-Resistance Rated ConstructionAaron McDonaldprogress
03/12/2026Fenestration and door U-factor and product ratingsAaron McDonaldenergy_progress
03/12/2026HVAC-R and service water piping design and insulationAaron McDonaldenergy_progress
03/12/2026HVAC-R and service water heating equipmentAaron McDonaldenergy_progress
03/12/2026Fenestration areasAaron McDonaldenergy_progress
03/12/2026Air barrier - visual inspectionAaron McDonaldenergy_progress
03/12/2026Interior lighting powerAaron McDonaldenergy_progress
03/12/2026HVAC-R and service water heating system controlsAaron McDonaldenergy_progress
03/12/2026Insulation placement and R valuesAaron McDonaldenergy_progress
03/12/2026Fenestration air leakageAaron McDonaldenergy_progress
▾Documents — 16 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/17/2026B01371164-S2Request digital key ↗
08/17/2026B01371164-I1Request digital key ↗
▸Seals & Professional Certifications13
▸DOB NOWProgress Inspector Seal & Signature10
08/23/2026B01371164-I1Open ↗
08/23/2026B01371164-I1Open ↗
08/23/2026B01371164-I1Open ↗
Showing 3 of 10 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/17/2026B01371164-I1Open ↗
08/17/2026B01371164-S2Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/23/2026B01371164-I1Open ↗
▸Environmental & Asbestos1
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/17/2026B01371164-I1Open ↗