← Back
Shopping center, with or without parking
153-15 CROSS ISLAND PARKWAY
QUEENS · Whitestone-Beechhurst · BIN 4433159
💬 Discuss this project
1955Year Built
2Stories
K6Building Class
R3-2Zoning
148,639 sfGross Floor Area
25Units
LL97 Covered3 Open Violations ▸FDNY Report ↗
Shopping center, with or without parking · Owner of record: REDMONT REALTY COMPANY LLC · 403,415 sf lot · 0.37 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralElectricalGeneral
Roof1p · 1 filing · 2 docs
Site & exterior2p · 1 filing · 8 docs
Filed — no permit issued3p · 3 filings · 6 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
REDMONT REALTY1903/21/2026
PM REALTY GROUP303/21/2026
CHASE MANHATTAN BANK303/21/2026
▾Design Consultants (Architect / Engineer of Record)
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
JP EXPEDITE403/21/2026
CCM CONSULTING GROUP, INC.103/21/2026
CONSTRUCTION PERMIT SERVICES203/21/2026
MUNICIPAL BUILDING CONSULTANTS203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
E.T. VANDERBECK INCGeneral Contractor303/21/2026
CIOFFI, JOHNElectrical103/21/2026
G V PLBG & HTG CORPElectrical103/21/2026
MULLIN, NEILElectrical103/21/2026
WINDLE, DElectrical103/21/2026
SIGNS CADScaffold107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
SCHERER DESIGN GROUP, LLC6303101/09/2019
R MARSAC CONSULTING LLC3291—
Building Lifecycle
All (49)Filed (5)Permit Issued (2)Signed Off (2)Violation (30)Objection (2)Special Inspection (8)
04/25/2023
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
04/04/2022
Signed off — Alteration
REPLACE ILLUMINATED, ACCESSORY BUSINESS CHANNEL LETTER WALL SIGN, REMOVE A PREVIOUS JOB #421530007, INSIDE OF PROPERTY LINE, NO CHANGE TO USE, EGRESS OR OCCUPATION
Q00589265-I1
10/27/2021
Special inspection requirement — Final
Hackjong Choi
10/25/2021
Filed — Alteration
REPLACE ILLUMINATED, ACCESSORY BUSINESS CHANNEL LETTER WALL SIGN, REMOVE A PREVIOUS JOB #421530007, INSIDE OF PROPERTY LINE, NO CHANGE TO USE, EGRESS OR OCCUPATION
Q00589265-P1
10/14/2021
Special inspection requirement — Concrete - Cast-In-Place
Robert Marsac
10/13/2021
Special inspection requirement — Final
Hackjong Choi
09/24/2021
Permit issued — Sign
Q00589265-I1-SG
09/23/2021
Filed — Alteration
REPLACE ILLUMINATED, ACCESSORY BUSINESS CHANNEL LETTER WALL SIGN, REMOVE A PREVIOUS JOB #421530007, INSIDE OF PROPERTY LINE, NO CHANGE TO USE, EGRESS OR OCCUPATION
Q00589265-I1
01/22/2021
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
02/11/2020
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
02/06/2020
Signed off — Alteration
REMOVAL OF AN EXISTING UNMANNED VERIZON TELECOMMUNICATIONS FACILITY LOCATED AT GRADE. INCLUDING THE REMOVAL OF NINE (9) EXISTING ANTENNAS AND ASSOCIATED APPURTENANCES AS WELL AS EQUIPMENT WITHIN AN EXISTING EQUIPMENT SHELTER. ALL IN CONFORMANCE WITH TPPN 5/98. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
Q00045734-I1
01/02/2020
Filed — Alteration
STRUCTURAL WORK CONSISTING OF COLD FORM METAL FRAMING FOR NEW SOFFIT FRAMING AT WHITESTONE SHOPPING CENTER as per plans filed herewith. no change to use, egress or occupancy.
Q00288437-I1
12/27/2019
Special inspection requirement — Structural Steel - Welding
12/27/2019
Special inspection requirement — Structural Cold-Formed Steel
12/27/2019
Special inspection requirement — Final
12/27/2019
Special inspection requirement — Structural Stability – Alterations of existing buildings
12/27/2019
Special inspection requirement — Structural Steel - Details
12/16/2019
Filed — Alteration
INSTALLATION OF 8 FOOT HIGH WOOD CONSTRUCTION FENCE AS PER PLANS FILED HEREWITH. NO CHANGE TO USE, EGRESS OR OCCUPANCY
Q00264905-I1
01/19/2019
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
01/14/2019
Permit issued — Antenna
Q00045734-I1-AN
01/09/2019
Filed — Alteration
REMOVAL OF AN EXISTING UNMANNED VERIZON TELECOMMUNICATIONS FACILITY LOCATED AT GRADE. INCLUDING THE REMOVAL OF NINE (9) EXISTING ANTENNAS AND ASSOCIATED APPURTENANCES AS WELL AS EQUIPMENT WITHIN AN EXISTING EQUIPMENT SHELTER. ALL IN CONFORMANCE WITH TPPN 5/98. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
Q00045734-I1
01/09/2019
Objection raised — 2014-AN AC 28-104.7.1-Administ
01/09/2019
Objection resolved — Addressed
01/19/2017
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
01/03/2017
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
11/14/2016
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
01/26/2016
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
08/19/2015
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
08/15/2014
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
08/15/2014
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
10/14/2011
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
03/19/2010
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
01/27/2010
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
01/01/2009
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
01/01/2009
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
05/20/2008
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
01/03/2008
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
01/03/2008
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
05/24/2007
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
01/19/2007
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
11/04/2005
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
01/25/2005
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
03/30/2004
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
09/16/1997
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
05/31/1994
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
06/28/1993
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
11/12/1991
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
10/12/1989
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
09/27/1988
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSignSigned-offSIGNS CAD CORP09/24/2021
DOB NOWAntennaSigned-offE.T. VANDERBECK INC01/14/2019
BIS—ISSUEDGOING SIGN & SVCNG CO,INC09/07/2017
BISOTISSUEDNUCOR CONSTRUCTION CORP09/25/2012
BISMHISSUEDNUCOR CONSTRUCTION CORP09/25/2012
BISOTISSUEDCONSTRUCTION EXPERT INC05/27/2010
BISOTISSUEDUPGRADE CONTR. CO. INC04/02/2009
BISOTISSUEDUPGRADE CONTR. CO. INC01/20/2009
BISOTISSUEDCORAM GLASS & MIRROR INC01/06/2009
BISEQISSUEDCORAM GLASS & MIRROR INC01/06/2009
BIS—ISSUEDNATIONAL MAINTEANANCE INC.07/14/2006
BISMHISSUEDBOTTO MECHANICAL CORP01/15/2004
BISBLISSUEDWEXLER PLUMBING & HEATING CORP10/04/2000
BISPLISSUEDWEXLER PLUMBING & HEATING CORP10/04/2000
BISPLISSUEDWILLIAM C. GERAKARIS P&H08/01/2000
BISOTISSUEDJGN CONSTRUCTION CORP03/31/2000
BISMHISSUEDJGN CONSTRUCTION CORP03/31/2000
BISOTISSUEDREAL CARPENTERS02/11/1999
BIS—ISSUEDBERGER SIGN FABRICATION INC10/27/1998
BIS—ISSUEDNORTH SHORE NEON SIGN CO.INC.05/07/1998
BIS—ISSUEDNORTH SHORE NEON SIGN CO.INC.05/07/1998
BIS—ISSUEDGOING SIGN & SVCNG CO,INC07/02/1997
BIS—ISSUEDGOING SIGN & SVCNG CO,INC06/19/1997
BIS—ISSUEDGOING SIGN & SVCNG CO,INC06/19/1997
BIS—ISSUEDGOING SIGN & SVCNG CO,INC06/19/1997
BIS—ISSUEDGOING SIGN & SVCNG CO,INC06/13/1997
BISOTISSUEDJGN CONST CORP04/30/1997
BISOTISSUEDJGN CONST CORP04/30/1997
BIS—ISSUEDUNIVERSAL ELECTRIC SIGN CO.,INC.10/13/1994
BIS—ISSUEDUNIVERSAL ELECTRIC SIGN CO.INC10/11/1994
BIS—ISSUEDUNIVERSAL ELECTRIC SIGN CO.,INC.10/05/1994
BISMHISSUEDNY PLG & HTG CORP04/16/1993
BISOTISSUEDMASTER ENVIROMENTAL BUSINESS COR04/01/1993
BISOTISSUEDH-E CONSTRUCTION RESTORATION03/10/1993
BIS—ISSUEDGOING SIGN CO.09/16/1991
BISMHISSUEDRNA AIR CONDITIONING SER09/13/1991
BISSPISSUEDEVER READY FIRE MONITORING SYSTE08/05/1991
BIS—ISSUEDCAPELLI ERECTORS INC04/02/1991
BIS—ISSUEDCAPELLI ERECTORS INC04/02/1991
BIS—ISSUEDCAPELLI ERECTORS INC04/02/1991
+ 2 more permits on file
1 project · most recent 10/13/2021
FiledStatusContractorScope
10/13/2021CompleteSIGNS CAD CORP—
1 project · most recent 01/02/2020
FiledStatusContractorScope
01/02/2020——1 scope_items
1 project · most recent 12/16/2019
Fence
FiledStatusContractorScope
12/16/2019——Fence
▾Special Inspection Requirements (DOB NOW) — 8
DateRequirementInspectorRole
10/27/2021FinalHackjong Choiprogress
10/14/2021Concrete - Cast-In-PlaceRobert Marsacspecial
10/13/2021FinalHackjong Choiprogress
12/27/2019Structural Steel - Welding—special
12/27/2019Structural Cold-Formed Steel—special
12/27/2019Final—progress
12/27/2019Structural Stability – Alterations of existing buildings—special
12/27/2019Structural Steel - Details—special
▾Documents — 116 on file (BIS + DOB NOW)
▸Plans & Drawings5
▸DOB NOWPlans/Sketch3
08/27/2026Q00589265-I1Request digital key ↗
08/27/2026Q00589265-P1Request digital key ↗
08/15/2026Q00045734-I1Request digital key ↗
▸DOB NOWPlans/Sketch - Structural1
08/28/2026Q00288437-I1Request digital key ↗
▸DOB NOWPlans/Sketch - Construction Fence1
08/28/2026Q00264905-I1Request digital key ↗
▸Applications & Permits21
▸BISPLAN / WORK APPROVAL APPLICATION15
01/27/2020421801795Open ↗
01/22/2020421782048Open ↗
01/14/2020421782048Open ↗
Showing 3 of 15 on file for this type
▸BISWORK PERMIT APPLICATION6
09/18/2017421530007Open ↗
09/28/2012420627646Open ↗
09/28/2012420627646Open ↗
Showing 3 of 6 on file for this type
▸Seals & Professional Certifications38
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION15
01/27/2020421801795Open ↗
01/06/2020421782048Open ↗
09/18/2017421530007Open ↗
Showing 3 of 15 on file for this type
▸BISPROFESSIONAL CERTIFIED CHECKLIST7
01/06/2020421782048Open ↗
09/18/2017421530007Open ↗
09/28/2012420627646Open ↗
Showing 3 of 7 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature6
08/28/2026Q00264905-I1Open ↗
08/27/2026Q00589265-P1Open ↗
08/27/2026Q00589265-I1Open ↗
Showing 3 of 6 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM5
09/28/2012420627646Open ↗
09/28/2012420627646Open ↗
05/05/2010420183964Open ↗
Showing 3 of 5 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT2
01/06/2020421782048Open ↗
09/18/2017421530007Open ↗
▸DOB NOWProgress Inspector Seal & Signature2
09/01/2026Q00589265-P1Open ↗
08/26/2026Q00589265-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/27/2026Q00610610-I1Open ↗
▸Safety & Tenant Protection2
▸BISSTREET TREE CHECKLIST2
05/05/2010420183964Open ↗
12/01/2008410199137Open ↗
▸Environmental & Asbestos10
▸BISASBESTOS: CERTIFICATION (DEP ACP5)4
01/27/2020421801795Open ↗
01/06/2020421782048Open ↗
09/18/2017421530007Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
08/27/2026Q00589265-I1Open ↗
08/27/2026Q00589265-P1Open ↗
08/13/2026Q00288437-I1Open ↗
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'2
05/05/2010420183964Open ↗
12/30/2008410206913Open ↗
▸BISASBESTOS EXEMPTION CERTIFICATION LETTER1
12/01/2008410199137Open ↗
▸Energy Compliance6
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS4
01/06/2020421782048Open ↗
04/12/2013420627646Open ↗
09/28/2012420627646Open ↗
Showing 3 of 4 on file for this type
▸BISAS-BUILT ENERGY ANALYSIS2
04/18/2013420627646Open ↗
04/12/2013420627646Open ↗
▸Approvals, Objections & Sign-offs10
▸BISLETTERS - SUPPORTING DOCUMENTATION4
04/18/2013420627646Open ↗
04/18/2013420627646Open ↗
06/14/2010420183964Open ↗
Showing 3 of 4 on file for this type
▸BISADMINISTRATIVE OBJECTIONS4
09/28/2012420627646Open ↗
05/05/2010420183964Open ↗
12/30/2008410206913Open ↗
Showing 3 of 4 on file for this type
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST2
04/18/2013420627646Open ↗
05/16/2011420183964Open ↗
▸Cost, Insurance & Ownership14
▸BISCOST AFFIDAVIT14
01/27/2020421801795Open ↗
01/06/2020421782048Open ↗
09/18/2017421530007Open ↗
Showing 3 of 14 on file for this type
▸Filing & Intake Forms10
▸BISEFILING COVER SHEET8
01/27/2020421801795Open ↗
01/06/2020421782048Open ↗
09/18/2017421530007Open ↗
Showing 3 of 8 on file for this type
▸BISADDITIONAL INFORMATION2
03/12/2020421801795Open ↗
01/23/2020421782048Open ↗