| Firm | Filings | Most Recent |
|---|---|---|
| D&E Build Evergreen | 3 | 02/05/2026 |
| Representative | Filings | Most Recent |
|---|---|---|
| Metro Design | 6 | 03/21/2026 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| Pencol Contracting | General Contractor | 2 | 08/05/2026 |
| Kishan Plumbing | Plumbing | 1 | 07/08/2026 |
| Agency | License # | Filings | Most Recent |
|---|---|---|---|
| NKM Engineering | 6244 | 2 | 09/13/2025 |
| Triangle Inspection & Tes | 7495 | 1 | 09/13/2025 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| DOB NOW | Mechanical Systems | Permit Issued | Pencol Contracting | 08/04/2026 |
| DOB NOW | Plumbing | Permit Issued | Kishan Plumbing | 06/04/2026 |
| DOB NOW | Structural | Permit Issued | Pencol Contracting | 05/18/2026 |
| Filed | Status | Contractor | Scope | Make / Model / Capacity |
|---|---|---|---|---|
| 02/05/2026 | Permit Issued | Pencol Contracting | Air Conditioning Systems, Heating Systems, Ventilation Systems | Cooling Cooper & Hunter CH-N48LCU-230VO 48,000 BTU · Condensing Unit ×2 CH-N60LCU-230VO 60,000 BTU · Condensing Unit ×2 Heating Ventilation Hampton Bay 7114-01 50 CFM · Exhaust Fan ×10 Delta Breeze SMT150 150 CFM · Kitchen Exhaust ×4 |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 02/05/2026 | — | — | Sprinkler System |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 02/05/2026 | Permit Issued | Kishan Plumbing | Storm, Water/Sanitary |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 02/05/2026 | Permit Issued | Pencol Contracting | Steel, Wood |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 02/05/2026 | Permit Issued | Pencol Contracting | Earthwork |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 03/09/2026 | Footing and Foundation | NARESH MAHANGU | progress |
| 03/09/2026 | Structural Steel - Details | NARESH MAHANGU | special |
| 03/09/2026 | Fenestration air leakage | NARESH MAHANGU | energy_progress |
| 03/09/2026 | HVAC-R and service water piping design and insulation | NARESH MAHANGU | energy_progress |
| 03/09/2026 | Permanent certificate | NARESH MAHANGU | energy_progress |
| 03/09/2026 | Fenestration and door U-factor and product ratings | NARESH MAHANGU | energy_progress |
| 03/09/2026 | Interior lighting power | NARESH MAHANGU | energy_progress |
| 03/09/2026 | Air barrier - visual inspection | NARESH MAHANGU | energy_progress |
| 03/09/2026 | Air barrier — testing | NARESH MAHANGU | energy_progress |
| 03/09/2026 | Heating Systems | NARESH MAHANGU | special |
| 03/09/2026 | Mechanical Systems | NARESH MAHANGU | special |
| 03/09/2026 | Excavations - Sheeting, Shoring, and Bracing | NARESH MAHANGU | special |
| 03/09/2026 | Masonry | NARESH MAHANGU | special |
| 03/09/2026 | Structural Steel - High Strength Bolting | NARESH MAHANGU | special |
| 03/09/2026 | Fire-Resistant Penetrations and Joints | NARESH MAHANGU | special |
| 03/09/2026 | Concrete - Cast-In-Place | NARESH MAHANGU | special |
| 03/09/2026 | Subgrade Inspections | NARESH MAHANGU | special |
| 03/09/2026 | Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation | NARESH MAHANGU | special |
| 03/09/2026 | Subsurface Investigations (Borings/Test Pits) | Rajasekhar Sakhamuri | special |
| 03/09/2026 | Structural Wood Frame | NARESH MAHANGU | progress |
| 03/09/2026 | Fire-Resistance Rated Construction | NARESH MAHANGU | progress |
| 03/09/2026 | Energy Code Compliance Inspections | NARESH MAHANGU | progress |
| 03/09/2026 | Final | PETER CHO | progress |
| 03/09/2026 | Fenestration areas | NARESH MAHANGU | energy_progress |
| 03/09/2026 | Ventilation and air distribution system | NARESH MAHANGU | energy_progress |