← Back
School or academy
Farber Building
153 PIERREPONT STREET · Brooklyn Heights · BIN 3001938
💬 Discuss this project
1954Year Built
6Stories
W3Building Class
C6-4Zoning
27,680 sfGross Floor Area
1Units
LL97 Covered0 Open ViolationsFDNY Report ↗
School or academy · Owner of record: SAINT ANNS SCHOOL · 3,979 sf lot · 6.96 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbingFire Protection
Permit Issued — active, not yet Signed-off
Roof2p · 1 filing · 20 docs
Floor 56p · 1 filing · 20 docs
Floor 45p · 1 filing · 20 docs
Floor 32p · 2 filings · 10 docs
Floor 2
Floor 1Under Construction34p · 2 filings · 20 docs
MezzanineUnder Construction27p · 2 filings · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
SAINT ANNS SCHOOL6209/07/2026
OWNER OF 153 PIERREPONT S303/22/2026
BROCKMED INC C/O PARKER M103/22/2026
BROOKLYN MEDICAL GROUP203/22/2026
ST ANNS SCHOOL3003/21/2026
PARKER MADISON PARTNERSHIP203/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
DERIVE ENGINEERS603/26/2026
MURRAY ENGINEERING PC107/15/2025
LEA ARCHITECTURE PLLC207/08/2025
POLISE CONSULTING ENGINEERS DPC207/14/2021
MARVEL ARCHITECTS107/14/2021
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
RPO2203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
YORKE CONSTRUCTION CORPGeneral Contractor709/07/2026
SAINT ANN'S SCHOOLGeneral Contractor407/08/2026
GO PRO FIRE PROTECTION CFire Protection207/08/2026
UNITED PLBG MECHANICAL INCFire Protection208/20/2026
CITY/SUBURBAN PLBG CORPPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
AMARACON TESTING & INSPEC58421003/26/2026
KLINE ENGINEERING, PC1007207/14/2021
Building Lifecycle
All (149)Filed (12)Permit Issued (14)Signed Off (6)Violation (46)Inspection (6)Objection (39)Special Inspection (26)
08/18/2026
Permit issued — Sprinklers
B01320762-I1-EW-SP
08/11/2026
Inspection — Fail-Final Boiler Equipment Inspection
Fail
View inspection ↗
08/05/2026
Permit issued — Mechanical Systems
B01213418-S1-MS
08/04/2026
Permit issued — Structural
B01213418-S3-ST
07/14/2026
Signed off — Alteration
Filing herewith for mechanical work as per the plans submitted. No change to egress, use, or occupancy.
B01200309-S2
06/17/2026
Special inspection requirement — Maintenance information
CONNIE PISANI
06/17/2026
Special inspection requirement — HVAC-R and service water heating equipment
CONNIE PISANI
06/17/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
CONNIE PISANI
06/17/2026
Special inspection requirement — Mechanical Systems
CONNIE PISANI
06/17/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
CONNIE PISANI
06/17/2026
Special inspection requirement — Final
CONNIE PISANI
06/17/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
CONNIE PISANI
06/17/2026
Special inspection requirement — Shutoff dampers
CONNIE PISANI
06/17/2026
Special inspection requirement — Duct leakage testing, insulation and design
CONNIE PISANI
06/17/2026
Special inspection requirement — HVAC-R and service water heating system controls
CONNIE PISANI
04/21/2026
Objection resolved — Resolved
04/15/2026
Objection raised — Cost
04/01/2026
Signed off — Alteration
Filing herewith for mechanical work as per the plans submitted. No change to egress, use, or occupancy.
B01200309-S1
03/31/2026
Signed off — Alteration
Filing herewith for mechanical work as per the plans submitted. No change to egress, use, or occupancy.
B01200309-I1
03/26/2026
Filed — Alteration CO
Filing herewith for new framing for 1st floor mezzanine and exiting framing reinforcing as per plans submitted.
B01213418-P1
03/26/2026
Permit issued — General Construction
B01213418-I1-GC
02/24/2026
Objection raised — Fire_Protection
02/10/2026
Filed — Alteration
B01320762-I1
11/18/2025
Special inspection requirement — Sprinkler Systems
CONNIE PISANI
09/23/2025
Special inspection requirement — Post-installed Anchors
CONNIE PISANI
09/23/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
CONNIE PISANI
09/23/2025
Special inspection requirement — Sprinkler Systems
CONNIE PISANI
09/16/2025
Filed — Alteration
Filing herewith for mechanical work as per the plans submitted. No change to egress, use, or occupancy.
B01200309-P1
09/10/2025
Objection resolved — Addressed
09/02/2025
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
08/12/2025
Permit issued — Mechanical Systems
B01213418-S1-MS
08/08/2025
Permit issued — Structural
B01213418-S3-ST
08/06/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
07/28/2025
Permit issued — Sprinklers
B01200309-S2-EW-SP
07/28/2025
Objection resolved — Addressed
07/25/2025
Permit issued — Plumbing
B01200309-S2-PL
07/23/2025
Objection raised — Other
07/21/2025
Objection raised — Energy
07/16/2025
Objection resolved — Addressed
07/16/2025
Objection resolved — Addressed
07/16/2025
Objection resolved — Addressed
07/16/2025
Objection resolved — Addressed
07/15/2025
Filed — Alteration CO
Filing herewith for new framing for 1st floor mezzanine and exiting framing reinforcing as per plans submitted.
B01213418-S3
07/15/2025
Objection resolved — Addressed
07/15/2025
Objection resolved — Addressed
07/09/2025
Filed — Alteration CO
Filing herewith for new framing for 1st floor mezzanine and exiting framing reinforcing as per plans submitted.
B01213418-S1
07/09/2025
Permit issued — General Construction
B01200309-I1-GC
07/08/2025
Filed — Alteration CO
Filing herewith for new framing for 1st floor mezzanine and exiting framing reinforcing as per plans submitted.
B01213418-I1
07/03/2025
Objection resolved — Addressed
07/03/2025
Objection resolved — Addressed
07/03/2025
Objection resolved — Addressed
07/03/2025
Objection resolved — Addressed
07/02/2025
Objection raised — Fire_Protection
07/02/2025
Objection raised — Inspections
07/02/2025
Objection resolved — Addressed
07/02/2025
Objection raised — Admin
07/02/2025
Objection raised — Zoning
07/02/2025
Objection raised — Electrical
06/30/2025
Permit issued — Mechanical Systems
B01200309-S1-MS
06/11/2025
Objection resolved — Addressed
Latest 60 of 149 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSprinklersPermit IssuedUNITED PLBG MECHANICAL INC08/18/2026
DOB NOWMechanical SystemsPermit IssuedYORKE CONSTRUCTION CORP08/05/2026
DOB NOWStructuralPermit IssuedYORKE CONSTRUCTION CORP08/04/2026
DOB NOWGeneral ConstructionPermit IssuedYORKE CONSTRUCTION CORP03/26/2026
DOB NOWMechanical SystemsPermit IssuedYORKE CONSTRUCTION CORP08/12/2025
DOB NOWStructuralPermit IssuedYORKE CONSTRUCTION CORP08/08/2025
DOB NOWSprinklersSigned-offUNITED PLBG MECHANICAL INC07/28/2025
DOB NOWPlumbingSigned-offCITY/SUBURBAN PLBG CORP07/25/2025
DOB NOWGeneral ConstructionSigned-offYORKE CONSTRUCTION CORP07/09/2025
DOB NOWMechanical SystemsSigned-offYORKE CONSTRUCTION CORP06/30/2025
DOB NOWSprinklersSigned-offGO PRO FIRE PROTECTION C03/10/2022
DOB NOWSprinklersSigned-offGO PRO FIRE PROTECTION C08/16/2021
DOB NOWMechanical SystemsSigned-offSAINT ANN'S SCHOOL07/21/2021
DOB NOWGeneral ConstructionSigned-offSAINT ANN'S SCHOOL07/21/2021
BISOTISSUEDSAINT ANN'S SCHOOL11/02/2016
BISMHISSUEDSAINT ANN'S SCHOOL11/02/2016
BISMHISSUEDSAINT ANN'S SCHOOL02/05/2016
BISOTISSUEDSAINT ANN'S SCHOOL02/05/2016
BIS—ISSUEDMARLITE CONST CORP06/30/2006
BISOTISSUEDSAINT PIERREPONT ST03/17/2005
BISPLISSUEDT-REX PLBG&HTG INC09/03/2003
BISPLISSUEDT-REX PLBG & HTG INC07/17/2003
BIS—ISSUEDSANIT ANN'S SCHOOL04/01/2003
BISFPISSUEDRELIABLE FIRE PROTECTION11/26/2002
BISEQRE-ISSUEDCOLAGTE SCAFFOLDING & EQUIPMENT08/26/2002
BISEQRE-ISSUEDCOLGATE SCAFFOLDING & EQUIPMENT08/26/2002
BISOTRE-ISSUEDBUILDERS GROUP07/25/2002
BISMHISSUEDBUILDERS GROUP07/25/2002
BISOTISSUEDBUILDERS GROUP07/25/2002
BISPLISSUEDT-REX PLBG & HTG INC06/17/2002
BISOTISSUEDBUILDERS GROUP05/31/2002
BISOTISSUEDBUILDERS GROUP05/31/2002
BISOTISSUEDBLDRS GROUP12/20/2001
BISOTISSUEDBLDRS GROUP12/20/2001
BISMHISSUEDGJF CONSTRUCTION CORP.06/28/2001
BISOTISSUEDBUILDERS GROUP05/22/2001
BISBLISSUEDJACK PICCINI, INC04/10/2001
BISEQISSUEDT.B.R. INC12/02/1998
BISOTISSUEDGALA RESTORATION INC11/23/1998
BISEQISSUEDYORK SCAFFOLDING07/23/1996
+ 5 more permits on file
2 projects · most recent 03/26/2026
Others Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
03/26/2026Permit IssuedYORKE CONSTRUCTION CORPOthers
Other
Price FGHC 71,080 BTU · Fan Coil Indoor ×8
09/16/2025Signed-offYORKE CONSTRUCTION CORPAir Conditioning Systems
Cooling
Mitsubishi Electric PUZ-AK12NL 12,000 BTU · Condensing Unit ×1
1 project · most recent 09/16/2025
Sprinkler System
FiledStatusContractorScope
09/16/2025Signed-offUNITED PLBG MECHANICAL INSprinkler System
1 project · most recent 09/16/2025
Water/Sanitary
FiledStatusContractorScope
09/16/2025Signed-offCITY/SUBURBAN PLBG CORPWater/Sanitary
3 projects · most recent 06/12/2026
General Wiring
FiledStatusContractorScope
06/12/2026Permit IssuedAPOLLO ELECTRIC INC.General Wiring
09/30/2025CompleteAPOLLO ELECTRIC INSDUS INGeneral Wiring
06/21/2023Permit Issued247 ELECTRICAL CORP—
1 project · most recent 03/26/2026
Steel
FiledStatusContractorScope
03/26/2026Permit IssuedYORKE CONSTRUCTION CORPSteel
▾Field Inspections (DOB CAP) — 6
DateTypeResultReport
08/11/2026Fail-Final Boiler Equipment InspectionFailView ↗
09/02/2025Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
08/06/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
06/29/2022Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
06/24/2022Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
06/23/2022Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 26
DateRequirementInspectorRole
06/17/2026Maintenance informationCONNIE PISANIenergy_progress
06/17/2026HVAC-R and service water heating equipmentCONNIE PISANIenergy_progress
06/17/2026Structural Stability – Alterations of existing buildingsCONNIE PISANIspecial
06/17/2026Mechanical SystemsCONNIE PISANIspecial
06/17/2026Fire-Resistant Penetrations and JointsCONNIE PISANIspecial
06/17/2026FinalCONNIE PISANIprogress
06/17/2026HVAC-R and service water piping design and insulationCONNIE PISANIenergy_progress
06/17/2026Shutoff dampersCONNIE PISANIenergy_progress
06/17/2026Duct leakage testing, insulation and designCONNIE PISANIenergy_progress
06/17/2026HVAC-R and service water heating system controlsCONNIE PISANIenergy_progress
11/18/2025Sprinkler SystemsCONNIE PISANIspecial
09/23/2025Post-installed AnchorsCONNIE PISANIspecial
09/23/2025Fire-Resistant Penetrations and JointsCONNIE PISANIspecial
09/23/2025Sprinkler SystemsCONNIE PISANIspecial
06/11/2025Structural Steel - High Strength BoltingCONNIE PISANIspecial
06/11/2025Structural Steel - WeldingCONNIE PISANIspecial
06/11/2025FinalCONNIE PISANIprogress
06/11/2025Structural Cold-Formed SteelCONNIE PISANIspecial
06/11/2025Structural Stability – Alterations of existing buildingsCONNIE PISANIspecial
06/11/2025Structural Steel - DetailsCONNIE PISANIspecial
03/26/2025Fire-Resistance Rated ConstructionCONNIE PISANIprogress
03/26/2025Interior lighting powerCONNIE PISANIenergy_progress
03/26/2025Lighting controlsCONNIE PISANIenergy_progress
03/26/2025Fire-Resistant Penetrations and JointsCONNIE PISANIspecial
03/25/2025FinalJane Leaprogress
Latest 25 of 26.
▾Documents — 88 on file (BIS + DOB NOW)
▸Plans & Drawings12
▸DOB NOWPlans/Sketch12
09/01/2026B00537096-I1Request digital key ↗
09/01/2026B00539048-I1Request digital key ↗
09/01/2026B00545939-I1Request digital key ↗
Showing 3 of 12 on file for this type
▸Applications & Permits8
▸BISWORK PERMIT APPLICATION4
11/02/2016321054540Open ↗
11/02/2016321054540Open ↗
02/10/2016321054540Open ↗
Showing 3 of 4 on file for this type
▸BISPLAN / WORK APPROVAL APPLICATION3
07/18/2014321054540Open ↗
07/18/2014321054540Open ↗
07/18/2014321201533Open ↗
▸BISPLAN - WORK & PERMITS - SUPPPORTING DOCUMENTATION1
03/28/2017321054540Open ↗
▸Seals & Professional Certifications29
▸DOB NOWDPL-1: Design Professional Seal & Signature12
09/01/2026B00537096-I1Open ↗
09/01/2026B00539048-I1Open ↗
09/01/2026B00545939-I1Open ↗
Showing 3 of 12 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature7
09/23/2026B01213418-S1Open ↗
09/23/2026B01213418-S1Open ↗
09/01/2026B01200309-I1Open ↗
Showing 3 of 7 on file for this type
▸DOB NOWProgress Inspector Seal & Signature6
09/23/2026B01213418-S1Open ↗
09/23/2026B01213418-S1Open ↗
09/01/2026B01200309-I1Open ↗
Showing 3 of 6 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION4
02/10/2016321054540Open ↗
02/10/2016321054540Open ↗
07/18/2014321054540Open ↗
Showing 3 of 4 on file for this type
▸Safety & Tenant Protection1
▸DOB NOWStreet Tree Checklist1
08/13/2026B01213418-I1Open ↗
▸Environmental & Asbestos14
▸DOB NOWDEP ACP-5: Asbestos Assessment Report12
09/01/2026B00537096-I1Open ↗
09/01/2026B00539048-I1Open ↗
09/01/2026B00545939-I1Open ↗
Showing 3 of 12 on file for this type
▸BISASBESTOS: CERTIFICATION (DEP ACP5)2
07/18/2014321054540Open ↗
07/18/2014321201533Open ↗
▸Energy Compliance4
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS3
02/10/2016321054540Open ↗
07/18/2014321054540Open ↗
07/18/2014321054540Open ↗
▸DOB NOWEN2: As Built Energy Analysis.1
08/13/2026B00539048-I1Open ↗
▸Approvals, Objections & Sign-offs13
▸DOB NOWFee Exempt Supporting Document - DOF ACRIS report or BIB letter12
09/01/2026B00537096-I1Open ↗
09/01/2026B00539048-I1Open ↗
09/01/2026B00545939-I1Open ↗
Showing 3 of 12 on file for this type
▸BISADMINISTRATIVE OBJECTIONS1
07/18/2014321201533Open ↗
▸Cost, Insurance & Ownership2
▸BISCOST AFFIDAVIT2
07/18/2014321054540Open ↗
07/18/2014321201533Open ↗
▸Filing & Intake Forms4
▸BISEFILING COVER SHEET3
07/18/2014321054540Open ↗
07/18/2014321054540Open ↗
07/18/2014321201533Open ↗
▸BISADDITIONAL INFORMATION1
04/05/2017321054540Open ↗
▸Other Documents1
▸DOB NOWProperty Ownership Certification1
08/13/2026B01213418-I1Open ↗