Locations of Work
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
Floor 2Hydraulically calculated sprinkler system for 3-family build1 filing · 4 docs
Floor 1Hydraulically calculated sprinkler system for 3-family build2 filings · 20 docs
CellarHydraulically calculated sprinkler system for 3-family build1 filing · 4 docs
Sub-BasementHydraulically calculated sprinkler system for 3-family build1 filing · 4 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
Metropolitan Homes203/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
Sideris Kefalas Engineers205/04/2026
Arnold Montag Architect AM/PM Desi204/25/2022
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
AM PM Design Consulting P203/21/2026
Building Lifecycle
All (60)Filed (4)Objection (26)Special Inspection (30)
09/23/2026
Objection raised — Other
09/23/2026
Objection raised — Other
09/23/2026
Objection raised — Other
05/15/2026
Objection raised — Other
05/12/2026
Objection raised — Cost
05/12/2026
Objection raised — Scope
05/04/2026
Filed — Alteration
HEREWITH FILING FOR HYDRAULICALLY CALCULATED SPRINKLER SYSTEM THROUGH-OUT BUILDING. FILED IN CONJUNCTION WITH NEW BUILDING, BIS # B00632050.
B00692051-P1
05/04/2026
Objection resolved — Resolved
05/04/2026
Objection resolved — Resolved
05/04/2026
Objection resolved — Resolved
05/04/2026
Objection resolved — Resolved
05/04/2026
Objection resolved — Resolved
05/04/2026
Objection resolved — Resolved
05/04/2026
Objection resolved — Resolved
05/04/2026
Objection resolved — Resolved
05/04/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
04/27/2026
Special inspection requirement — Sprinkler Systems
09/19/2025
Objection raised — Scope
09/08/2025
Special inspection requirement — Wood – Seismic Resistance
09/08/2025
Special inspection requirement — Permanent certificate
01/11/2023
Objection raised — Structural
09/27/2022
Objection resolved — Addressed
09/27/2022
Objection resolved — Addressed
04/25/2022
Filed — New Building
Proposed three story w cellar 3 family dwelling
B00632050-S1
04/19/2022
Filed — Alteration
HEREWITH FILING FOR HYDRAULICALLY CALCULATED SPRINKLER SYSTEM THROUGH-OUT BUILDING. FILED IN CONJUNCTION WITH NEW BUILDING, BIS # B00632050.
B00692051-I1
03/04/2022
Special inspection requirement — Sprinkler Systems
02/23/2022
Objection raised — Accessibility
02/23/2022
Objection raised — Structural
02/23/2022
Objection raised — Fire_Protection
02/23/2022
Objection raised — Zoning
02/23/2022
Objection raised — Fire_Protection
02/23/2022
Objection raised — Fire_Protection
02/23/2022
Objection raised — Other
02/23/2022
Objection raised — Other
02/15/2022
Filed — New Building
Proposed three story w cellar 3 family dwelling
B00632050-I1
01/26/2022
Special inspection requirement — Concrete - Cast-In-Place
01/26/2022
Special inspection requirement — Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation
01/26/2022
Special inspection requirement — Structural Steel - Details
01/26/2022
Special inspection requirement — Subgrade Inspections
01/26/2022
Special inspection requirement — Wood – Prefabricated I-Joists
01/26/2022
Special inspection requirement — Structural Cold-Formed Steel
01/26/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
01/26/2022
Special inspection requirement — Ventilation and air distribution system
01/26/2022
Special inspection requirement — Excavations - Sheeting, Shoring, and Bracing
01/26/2022
Special inspection requirement — Masonry
01/26/2022
Special inspection requirement — Subsurface Investigations (Borings/Test Pits)
01/26/2022
Special inspection requirement — Energy Code Compliance Inspections
01/26/2022
Special inspection requirement — Fire-Resistance Rated Construction
01/26/2022
Special inspection requirement — Structural Wood Frame
01/26/2022
Special inspection requirement — Fenestration air leakage
01/26/2022
Special inspection requirement — Lighting controls
01/26/2022
Special inspection requirement — HVAC-R and service water heating system controls
01/26/2022
Special inspection requirement — Fenestration and door U-factor and product ratings
01/26/2022
Special inspection requirement — Fenestration areas
01/26/2022
Special inspection requirement — Lighting in dwelling units
01/26/2022
Special inspection requirement — HVAC-R and service water piping design and insulation
01/26/2022
Special inspection requirement — Exterior Insulation and Finish Systems (EIFS)
01/26/2022
Special inspection requirement — HVAC-R and service water heating equipment
01/26/2022
Special inspection requirement — Interior lighting power
01/26/2022
Special inspection requirement — Maintenance information
Nothing on file for this building.
1 project · most recent 04/25/2022
Heating Systems Others
FiledStatusContractorScopeMake / Model / Capacity
04/25/2022——Heating Systems, Others
Heating
Williamson GWI-047 40,000 BTU · Boiler ×3
Other
Greenheck SP-B80 75 CFM · Exhaust Fan ×7
SP-A190 4 CFM · Kitchen Exhaust ×3
1 project · most recent 05/04/2026
FiledStatusContractorScope
05/04/2026———
1 project · most recent 04/25/2022
Concrete Masonry Wood
FiledStatusContractorScope
04/25/2022——Concrete, Masonry, Wood
▾Special Inspection Requirements (DOB NOW) — 40
DateRequirementInspectorRole
05/04/2026Fire-Resistant Penetrations and Joints—special
04/27/2026Sprinkler Systems—special
09/08/2025Wood – Seismic Resistance—special
09/08/2025Permanent certificate—energy_progress
03/04/2022Sprinkler Systems—special
01/26/2022Concrete - Cast-In-Place—special
01/26/2022Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation—special
01/26/2022Structural Steel - Details—special
01/26/2022Subgrade Inspections—special
01/26/2022Wood – Prefabricated I-Joists—special
01/26/2022Structural Cold-Formed Steel—special
01/26/2022Fire-Resistant Penetrations and Joints—special
01/26/2022Ventilation and air distribution system—energy_progress
01/26/2022Excavations - Sheeting, Shoring, and Bracing—special
01/26/2022Masonry—special
01/26/2022Subsurface Investigations (Borings/Test Pits)—special
01/26/2022Energy Code Compliance Inspections—progress
01/26/2022Fire-Resistance Rated Construction—progress
01/26/2022Structural Wood Frame—progress
01/26/2022Fenestration air leakage—energy_progress
01/26/2022Lighting controls—energy_progress
01/26/2022HVAC-R and service water heating system controls—energy_progress
01/26/2022Fenestration and door U-factor and product ratings—energy_progress
01/26/2022Fenestration areas—energy_progress
01/26/2022Lighting in dwelling units—energy_progress
Latest 25 of 40.
▾Documents — 20 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch4
08/31/2026B00632050-S1Request digital key ↗
08/17/2026B00692051-I1Request digital key ↗
08/15/2026B00692051-P1Request digital key ↗
Showing 3 of 4 on file for this type
▸Zoning, Tax Lot & Property Records4
▸DOB NOWZD1: DOB Zoning Diagram2
08/15/2026B00632050-I1Open ↗
08/13/2026B00632050-I1Open ↗
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026B00632050-I1Open ↗
▸DOB NOWZoning Exhibit form (1-5)1
08/15/2026B00632050-I1Open ↗
▸Seals & Professional Certifications4
▸DOB NOWDPL-1: Design Professional Seal & Signature4
08/17/2026B00692051-P1Open ↗
08/13/2026B00632050-S1Open ↗
08/13/2026B00692051-I1Open ↗
Showing 3 of 4 on file for this type
▸Trade Schedules & Equipment2
▸DOB NOWDEP: Sewer Certification (Sanitary/Storm)2
08/31/2026B00632050-I1Open ↗
08/13/2026B00632050-I1Open ↗
▸Safety & Tenant Protection2
▸DOB NOWStreet Tree Checklist1
08/13/2026B00632050-I1Open ↗
▸DOB NOWParks Department Acknowledgment Letter for Street Trees Plan1
08/13/2026B00632050-I1Open ↗
▸Energy Compliance1
▸DOB NOWEN2: As Built Energy Analysis1
08/13/2026B00632050-I1Open ↗
▸Inspections & Test Reports1
▸DOB NOWSOIL REPORT1
08/13/2026B00632050-I1Open ↗
▸Other Documents2
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone1
08/13/2026B00632050-I1Open ↗
▸DOB NOWProperty Ownership Certification1
08/13/2026B00632050-I1Open ↗