← Back
BuildNYC
Over six families without stores
155 ELDERT STREET
BROOKLYN · BIN 3326291
💬 Discuss this project
1983Year Built
3Stories
C1Building Class
R6Zoning
23,940 sfGross Floor Area
24Units
Rent Stabilized1 Active Violation 0 unresolved · 1 paperwork only ▸FDNY Report ↗
Over six families without stores · Owner of record: Bushwick Gardens 1 · 44,071 sf lot · 0.54 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralElectricalMechanicalPlumbingEquipmentCivilGeneral
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
Floor 1Unit 1A, Unit 1B, Unit 1C +12p · 1 filing · 7 docs
CellarBushwick Gardens - Group a42p · 2 filings · 20 docs
Site & exteriorFoundation and site work37p · 4 filings · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
Pennrose4807/08/2026
Bushwick Gardens803/22/2026
New York City Housing Authority803/21/2026
79 Captains Court407/08/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
Cameron Engineering812/12/2025
IMEG Consulting101/18/2024
Christopher Compton405/13/2022
Lombardo Professional Engineering102/23/2021
Scalar Architecture109/19/2019
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
ECC803/21/2026
Lombardo Building Consultants203/21/2026
AE Design Solution203/21/2026
JM Zoning1803/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
Procida ConstructionGeneral Contractor907/08/2026
J-J PlumbingPlumbing607/08/2026
Interstate Restorationspecialty_contractor303/21/2026
Thorn ElectricElectrical103/21/2026
SNB Electrical ContngElectrical103/22/2026
Deborah Bradley Cons & MGScaffold107/08/2026
Procida ConstructionScaffold107/08/2026
G.M.A. Plumbing & HeatingPlumbing107/08/2026
Prospect Electric ServiceElectrical103/21/2026
?John SR MariElectrical103/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
Tectonic Engineering Cons106912/12/2025
Environmental Code Consulting5516405/13/2022
Building Lifecycle
All (103)Filed (15)Permit Issued (16)Signed Off (7)Violation (24)Inspection (11)Special Inspection (30)
10/05/2026
Signed off — Alteration
RENOVATION OF 3-STORY NYCHA MULTIPLE DWELLING AS PART OF THE NYCHA PACT RENOVATION: PROVIDE SUPPORT FOR NEW EXTERIOR BOILER ROOM POD; NO CHANGES TO USE, EGRESS OR OCCUPANCY.
B00959408-I1
08/31/2026
Signed off — Alteration
DECOMMISSION AND ABANDON IN PLACE EXISTING INDIRECT DOMESTIC WATER HEATERS, RECIRCULATION PUMP, AND ASSOCIATED PIPING WITH VALVES; PROVIDE NEW DOMESTIC WATER AND GAS PIPING FROM THE CEL TO A NEW BOILER POD. NO CHANGES TO USE, EGRESS, OR OCCUPANCY.
B00959465-S5
04/27/2026
Permit issued — Foundation
B00959408-I1-GC-CX
04/07/2026
Inspection — Certified Storm Drainage-ST-Fixtures-Finish
Certified
View inspection ↗
04/06/2026
Inspection — Certified Storm Drainage-ST-Piping-Roughing
Certified
View inspection ↗
12/12/2025
Filed — Alteration
DECOMMISSION AND ABANDON IN PLACE EXISTING INDIRECT DOMESTIC WATER HEATERS, RECIRCULATION PUMP, AND ASSOCIATED PIPING WITH VALVES; PROVIDE NEW DOMESTIC WATER AND GAS PIPING FROM THE CEL TO A NEW BOILER POD. NO CHANGES TO USE, EGRESS, OR OCCUPANCY.
B00959465-P4
12/12/2025
Special inspection requirement — Sprinkler Systems
GEORGE GHEBRYAL
12/12/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
GEORGE GHEBRYAL
12/12/2025
Special inspection requirement — Post-installed Anchors
GEORGE GHEBRYAL
12/12/2025
Special inspection requirement — Tenant Protection Plan Compliance
12/11/2025
Special inspection requirement — Tenant Protection Plan Compliance
12/09/2025
Special inspection requirement — Sprinkler Systems
GEORGE GHEBRYAL
12/09/2025
Special inspection requirement — Post-installed Anchors
GEORGE GHEBRYAL
12/09/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
GEORGE GHEBRYAL
10/17/2025
Permit issued — Plumbing
B00959465-S2-PL
10/16/2025
Permit issued — Mechanical Systems
B00959465-I1-MS
08/05/2025
Filed — Alteration
DECOMMISSION AND ABANDON IN PLACE EXISTING INDIRECT DOMESTIC WATER HEATERS, RECIRCULATION PUMP, AND ASSOCIATED PIPING WITH VALVES; PROVIDE NEW DOMESTIC WATER AND GAS PIPING FROM THE CEL TO A NEW BOILER POD. NO CHANGES TO USE, EGRESS, OR OCCUPANCY.
B00959465-P3
07/25/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
GEORGE GHEBRYAL
07/25/2025
Special inspection requirement — Post-installed Anchors
GEORGE GHEBRYAL
07/25/2025
Special inspection requirement — Sprinkler Systems
GEORGE GHEBRYAL
07/25/2025
Special inspection requirement — Tenant Protection Plan Compliance
05/02/2025
Inspection — Pass-Final Boiler Equipment Inspection
Pass
View inspection ↗
04/09/2025
Permit issued — Plumbing
B00959465-S4-PL
04/08/2025
Permit issued — Boiler Equipment
B00959465-S5-BE
03/31/2025
Violation issued (ECB, open)
Boilers
03/28/2025
Permit issued — Boiler Equipment
B00959465-S5-BE
03/19/2025
Permit issued — Structural
B00959408-I1-GC-CX
02/25/2025
Filed — Alteration
DECOMMISSION AND ABANDON IN PLACE EXISTING INDIRECT DOMESTIC WATER HEATERS, RECIRCULATION PUMP, AND ASSOCIATED PIPING WITH VALVES; PROVIDE NEW DOMESTIC WATER AND GAS PIPING FROM THE CEL TO A NEW BOILER POD. NO CHANGES TO USE, EGRESS, OR OCCUPANCY.
B00959465-S5
02/13/2025
Filed — Alteration
DECOMMISSION AND ABANDON IN PLACE EXISTING INDIRECT DOMESTIC WATER HEATERS, RECIRCULATION PUMP, AND ASSOCIATED PIPING WITH VALVES; PROVIDE NEW DOMESTIC WATER AND GAS PIPING FROM THE CEL TO A NEW BOILER POD. NO CHANGES TO USE, EGRESS, OR OCCUPANCY.
B00959465-P2
02/05/2025
Special inspection requirement — Maintenance information
GEORGE GHEBRYAL
02/05/2025
Special inspection requirement — HVAC-R and service water heating system controls
GEORGE GHEBRYAL
02/05/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
GEORGE GHEBRYAL
02/05/2025
Special inspection requirement — HVAC-R and service water heating equipment
GEORGE GHEBRYAL
02/05/2025
Special inspection requirement — Heating Systems
GEORGE GHEBRYAL
02/05/2025
Special inspection requirement — Tenant Protection Plan Compliance
GEORGE GHEBRYAL
01/06/2025
Special inspection requirement — Tenant Protection Plan Compliance
01/06/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
GEORGE GHEBRYAL
01/06/2025
Special inspection requirement — Post-installed Anchors
GEORGE GHEBRYAL
01/06/2025
Special inspection requirement — Sprinkler Systems
GEORGE GHEBRYAL
11/26/2024
Signed off — Alteration
DECOMMISSION AND ABANDON IN PLACE EXISTING INDIRECT DOMESTIC WATER HEATERS, RECIRCULATION PUMP, AND ASSOCIATED PIPING WITH VALVES; PROVIDE NEW DOMESTIC WATER AND GAS PIPING FROM THE CEL TO A NEW BOILER POD. NO CHANGES TO USE, EGRESS, OR OCCUPANCY.
B00959465-S3
06/28/2024
Inspection — Certified Storm Drainage-ST-Piping-Underground
Certified
View inspection ↗
06/28/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
05/15/2024
Inspection — Certified Gas-Gas-Piping-Underground
Certified
View inspection ↗
05/15/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
05/09/2024
Permit issued — Plumbing
B00959465-S4-PL
05/03/2024
Inspection — Certified Gas-Gas-Piping-Underground
Certified
View inspection ↗
04/29/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
04/29/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
04/03/2024
Permit issued — Plumbing
B00959465-S2-PL
03/26/2024
Permit issued — Structural
B00959408-I1-GC-CX
03/20/2024
Permit issued — Earth Work
B00959465-S3-GC-CX
02/08/2024
Permit issued — Mechanical Systems
B00959465-I1-MS
01/18/2024
Filed — Alteration
RENOVATION OF 3-STORY NYCHA MULTIPLE DWELLING AS PART OF THE NYCHA PACT RENOVATION: PROVIDE SUPPORT FOR NEW EXTERIOR BOILER ROOM POD; NO CHANGES TO USE, EGRESS OR OCCUPANCY.
B00959408-I1
01/17/2024
Filed — Alteration
DECOMMISSION AND ABANDON IN PLACE EXISTING INDIRECT DOMESTIC WATER HEATERS, RECIRCULATION PUMP, AND ASSOCIATED PIPING WITH VALVES; PROVIDE NEW DOMESTIC WATER AND GAS PIPING FROM THE CEL TO A NEW BOILER POD. NO CHANGES TO USE, EGRESS, OR OCCUPANCY.
B00959465-S4
01/12/2024
Filed — Alteration
DECOMMISSION AND ABANDON IN PLACE EXISTING INDIRECT DOMESTIC WATER HEATERS, RECIRCULATION PUMP, AND ASSOCIATED PIPING WITH VALVES; PROVIDE NEW DOMESTIC WATER AND GAS PIPING FROM THE CEL TO A NEW BOILER POD. NO CHANGES TO USE, EGRESS, OR OCCUPANCY.
B00959465-S3
01/04/2024
Filed — Alteration
DECOMMISSION AND ABANDON IN PLACE EXISTING INDIRECT DOMESTIC WATER HEATERS, RECIRCULATION PUMP, AND ASSOCIATED PIPING WITH VALVES; PROVIDE NEW DOMESTIC WATER AND GAS PIPING FROM THE CEL TO A NEW BOILER POD. NO CHANGES TO USE, EGRESS, OR OCCUPANCY.
B00959465-S2
01/04/2024
Filed — Alteration
DECOMMISSION AND ABANDON IN PLACE EXISTING INDIRECT DOMESTIC WATER HEATERS, RECIRCULATION PUMP, AND ASSOCIATED PIPING WITH VALVES; PROVIDE NEW DOMESTIC WATER AND GAS PIPING FROM THE CEL TO A NEW BOILER POD. NO CHANGES TO USE, EGRESS, OR OCCUPANCY.
B00959465-I1
12/14/2023
Special inspection requirement — Structural Stability – Alterations of existing buildings
GEORGE GHEBRYAL
12/07/2023
Special inspection requirement — Tenant Protection Plan Compliance
GEORGE GHEBRYAL
12/06/2023
Special inspection requirement — Excavations - Sheeting, Shoring, and Bracing
GEORGE GHEBRYAL
Latest 60 of 103 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWFoundationSigned-offProcida Construction04/27/2026
DOB NOWPlumbingSigned-offJ-J Plumbing10/17/2025
DOB NOWMechanical SystemsPermit IssuedProcida Construction10/16/2025
DOB NOWPlumbingPermit IssuedJ-J Plumbing04/09/2025
DOB NOWBoiler EquipmentSigned-offJ-J Plumbing04/08/2025
DOB NOWBoiler EquipmentSigned-offJ-J Plumbing03/28/2025
DOB NOWStructuralSigned-offProcida Construction03/19/2025
DOB NOWPlumbingPermit IssuedJ-J Plumbing05/09/2024
DOB NOWPlumbingSigned-offJ-J Plumbing04/03/2024
DOB NOWStructuralSigned-offProcida Construction03/26/2024
DOB NOWEarth WorkSigned-offProcida Construction03/20/2024
DOB NOWMechanical SystemsPermit IssuedProcida Construction02/08/2024
DOB NOWGeneral ConstructionSigned-offInterstate Restoration04/28/2022
DOB NOWBoiler EquipmentSigned-offG.M.A. Plumbing & Heating01/12/2022
DOB NOWConstruction FenceSigned-offDeborah Bradley Cons & MG02/24/2021
DOB NOWConstruction FenceSigned-offProcida Construction09/19/2019
BISOTISSUEDProcida Construction04/26/2021
BISMHISSUEDProcida Construction04/26/2021
BISBLISSUEDTT Mechanical12/15/2020
BISPLISSUEDTT Mechanical12/15/2020
BISMHISSUEDProcida Construction05/04/2020
BISOTISSUEDProcida Construction05/04/2020
BISOTISSUEDBright Power Installation03/13/2020
BISBLISSUEDTT Mechanical11/25/2019
BISPLISSUEDTT Mechanical10/02/2019
BISBLISSUEDTT Mechanical10/02/2019
BISOTISSUEDProcida Construction09/20/2019
BISMHISSUEDProcida Construction09/20/2019
1 project · most recent 12/12/2025
Heating Systems
FiledStatusContractorScopeMake / Model / Capacity
12/12/2025Permit IssuedProcida ConstructionHeating Systems
Heating
Raypak H7-800B 800,000 BTU · Boiler ×2
1 project · most recent 12/12/2025
FiledStatusContractorScope
12/12/2025——15 heads
1 project · most recent 12/12/2025
Gas Plumbing-Sprinkler Storm Water/Sanitary
FiledStatusContractorScope
12/12/2025Signed-offJ-J PlumbingGas, Plumbing-Sprinkler, Storm, Water/Sanitary
4 projects · most recent 01/08/2026
General Wiring
FiledStatusContractorScope
01/08/2026Permit IssuedHI-Lights Electrical—
05/08/2024Permit IssuedSNB Electrical ContngGeneral Wiring
03/13/2020CompleteVenture Home Solar—
10/04/2019Permit IssuedE & M Electrical NYGeneral Wiring
2 projects · most recent 12/12/2025
Steel
FiledStatusContractorScope
12/12/2025Signed-offJ-J Plumbing1 scope_items
01/18/2024Signed-offProcida ConstructionSteel
1 project · most recent 12/12/2025
Earthwork Tenant Protection Plan 72 Hour
FiledStatusContractorScope
12/12/2025Signed-offJ-J PlumbingEarthwork, Tenant Protection Plan 72 Hour
▾Field Inspections (DOB CAP) — 11
DateTypeResultReport
04/07/2026Certified Storm Drainage-ST-Fixtures-FinishCertifiedView ↗
04/06/2026Certified Storm Drainage-ST-Piping-RoughingCertifiedView ↗
05/02/2025Pass-Final Boiler Equipment InspectionPassView ↗
06/28/2024Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
06/28/2024Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
05/15/2024Certified Gas-Gas-Piping-UndergroundCertifiedView ↗
05/15/2024Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
05/03/2024Certified Gas-Gas-Piping-UndergroundCertifiedView ↗
04/29/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
04/29/2024Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
06/13/2022Pass-Final Boiler Equipment InspectionPassView ↗
▾Special Inspection Requirements (DOB NOW) — 60
DateRequirementInspectorRole
12/12/2025Sprinkler SystemsGEORGE GHEBRYALspecial
12/12/2025Fire-Resistant Penetrations and JointsGEORGE GHEBRYALspecial
12/12/2025Post-installed AnchorsGEORGE GHEBRYALspecial
12/12/2025Tenant Protection Plan Compliance—special
12/11/2025Tenant Protection Plan Compliance—special
12/09/2025Sprinkler SystemsGEORGE GHEBRYALspecial
12/09/2025Post-installed AnchorsGEORGE GHEBRYALspecial
12/09/2025Fire-Resistant Penetrations and JointsGEORGE GHEBRYALspecial
07/25/2025Fire-Resistant Penetrations and JointsGEORGE GHEBRYALspecial
07/25/2025Post-installed AnchorsGEORGE GHEBRYALspecial
07/25/2025Sprinkler SystemsGEORGE GHEBRYALspecial
07/25/2025Tenant Protection Plan Compliance—special
02/05/2025Maintenance informationGEORGE GHEBRYALenergy_progress
02/05/2025HVAC-R and service water heating system controlsGEORGE GHEBRYALenergy_progress
02/05/2025HVAC-R and service water piping design and insulationGEORGE GHEBRYALenergy_progress
02/05/2025HVAC-R and service water heating equipmentGEORGE GHEBRYALenergy_progress
02/05/2025Heating SystemsGEORGE GHEBRYALspecial
02/05/2025Tenant Protection Plan ComplianceGEORGE GHEBRYALspecial
01/06/2025Tenant Protection Plan Compliance—special
01/06/2025Fire-Resistant Penetrations and JointsGEORGE GHEBRYALspecial
01/06/2025Post-installed AnchorsGEORGE GHEBRYALspecial
01/06/2025Sprinkler SystemsGEORGE GHEBRYALspecial
12/14/2023Structural Stability – Alterations of existing buildingsGEORGE GHEBRYALspecial
12/07/2023Tenant Protection Plan ComplianceGEORGE GHEBRYALspecial
12/06/2023Excavations - Sheeting, Shoring, and BracingGEORGE GHEBRYALspecial
Latest 25 of 60.
▾Documents — 200 on file (BIS + DOB NOW)
▸Plans & Drawings15
▸DOB NOWPlans/Sketch13
08/31/2026B00606781-I1Request digital key ↗
08/31/2026B00606781-P1Request digital key ↗
08/31/2026B00606781-P2Request digital key ↗
Showing 3 of 13 on file for this type
▸DOB NOWPlans/Sketch - Construction Fence2
09/02/2026B00230428-I1Request digital key ↗
09/01/2026B00469991-I1Request digital key ↗
▸Applications & Permits31
▸BISPLAN / WORK APPROVAL APPLICATION23
02/09/2022321072502Open ↗
01/31/2022321072502Open ↗
11/12/2021321072502Open ↗
Showing 3 of 23 on file for this type
▸BISWORK PERMIT APPLICATION6
03/13/2020340721455Open ↗
03/11/2020340721455Open ↗
10/03/2019321072502Open ↗
Showing 3 of 6 on file for this type
▸BISPLAN - WORK & PERMITS - SUPPPORTING DOCUMENTATION2
05/13/2020321072502Open ↗
08/26/2019321072502Open ↗
▸Seals & Professional Certifications46
▸DOB NOWSpecial Inspector Seal & Signature15
09/23/2026B00959465-P4Open ↗
09/23/2026B00959465-S5Open ↗
09/02/2026B00606781-P2Open ↗
Showing 3 of 15 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature15
09/01/2026B00469991-I1Open ↗
08/31/2026B00606781-I1Open ↗
08/31/2026B00606781-P1Open ↗
Showing 3 of 15 on file for this type
▸DOB NOWProgress Inspector Seal & Signature7
09/23/2026B00959465-S5Open ↗
09/01/2026B00959408-I1Open ↗
09/01/2026B00959465-S3Open ↗
Showing 3 of 7 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION6
09/11/2019321072502Open ↗
09/11/2019321072502Open ↗
06/28/2019321072502Open ↗
Showing 3 of 6 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
03/11/2020340721455Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
03/11/2020340721455Open ↗
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION1
03/11/2020340721455Open ↗
▸Trade Schedules & Equipment17
▸BISSCHEDULE B - PLUMBING9
02/09/2022321072502Open ↗
01/31/2022321072502Open ↗
11/12/2021321072502Open ↗
Showing 3 of 9 on file for this type
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE2
06/27/2019321072502Open ↗
11/21/2018321072502Open ↗
▸BISSCHEDULE C - HEATING & COMBUSTION EQUIPMENT2
05/21/2020321072502Open ↗
11/21/2018321072502Open ↗
▸BISFA - FDNY APPROVAL : FD-FAA1
07/19/2020321568219Open ↗
▸BISHVAC & SERVICE WATER HEATING EQUIPMENT1
03/08/2022321072502Open ↗
▸BISHVAC & SERVICE WATER HEATING SYSTEM CONTROLS1
03/08/2022321072502Open ↗
▸BISHEATING SYSTEMS1
03/08/2022321072502Open ↗
▸Safety & Tenant Protection3
▸BISTENANT PROTECTION PLAN AND NOTES2
03/11/2020340721455Open ↗
11/21/2018321072502Open ↗
▸DOB NOWTenant Protection Plan1
08/13/2026B00230428-I1Open ↗
▸Environmental & Asbestos11
▸DOB NOWDEP ACP-5: Asbestos Assessment Report9
08/31/2026B00606781-I1Open ↗
08/31/2026B00606781-P1Open ↗
08/31/2026B00606781-P2Open ↗
Showing 3 of 9 on file for this type
▸BISDEP ASBESTOS PROJECT COMPLETION FORM1
09/23/2019321072502Open ↗
▸BISASBESTOS: COMPLETION OR CLOSEOUT (ACP20/21/5)1
09/23/2019321072502Open ↗
▸Energy Compliance20
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS4
09/11/2019321072502Open ↗
06/28/2019321072502Open ↗
06/28/2019321072502Open ↗
Showing 3 of 4 on file for this type
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY2
06/16/2021340721455Open ↗
03/11/2020340721455Open ↗
▸BISAS-BUILT ENERGY ANALYSIS (EN2)2
03/08/2022321072502Open ↗
06/16/2021340721455Open ↗
▸BISINTERIOR LIGHTING POWER1
03/08/2022321072502Open ↗
▸BISFENESTRATION U-FACTOR & PRODUCT RATING1
03/08/2022321072502Open ↗
▸BISFENESTRATION AREAS1
03/08/2022321072502Open ↗
▸BISENERGY CODE COMPLIANCE INSPECTIONS1
03/08/2022321072502Open ↗
▸BISELECTRIC MOTORS1
03/08/2022321072502Open ↗
▸BIS* HVAC INSULATION AND SEALING1
03/08/2022321072502Open ↗
▸BISLIGHTING IN DWELLING UNITS1
03/08/2022321072502Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY FOR ENERGY CODE PROGRESS INSPECTIONS1
03/11/2020340721455Open ↗
▸BISELECTRICAL ENERGY CONSUMPTION1
03/08/2022321072502Open ↗
▸BISEXTERIOR LIGHTING POWER1
03/08/2022321072502Open ↗
▸BISFENESTRATION AIR LEAKAGE1
03/08/2022321072502Open ↗
▸BISAIR SEALING AND INSULATION - VISUAL1
03/08/2022321072502Open ↗
▸Inspections & Test Reports11
▸BISTECHNICAL REPORT: RESPONSIBILITY2
06/16/2021340721455Open ↗
03/11/2020340721455Open ↗
▸DOB NOWTR4 Test Report and Plot Diagram2
08/13/2026B00959465-S3Open ↗
08/13/2026B00959408-I1Open ↗
▸DOB NOWSOIL REPORT2
08/13/2026B00959408-I1Open ↗
08/13/2026B00959465-S3Open ↗
▸BISFIRE-RESISTANT PENETRATIONS AND JOINTS (FIRESTOP)1
03/08/2022321072502Open ↗
▸BISFIRE-RESISTIVE RATED CONSTRUCTION1
03/08/2022321072502Open ↗
▸BISMECHANICAL SYSTEMS1
03/08/2022321072502Open ↗
▸BISHIGH TEMPERATURE HOT WATER PIPING (WELDING)1
03/08/2022321072502Open ↗
▸BISCONCRETE - CAST-IN-PLACE1
03/08/2022321072502Open ↗
▸Approvals, Objections & Sign-offs22
▸DOB NOWFee Exempt Supporting Document - DOF ACRIS report or BIB letter15
09/01/2026B00469991-I1Open ↗
08/31/2026B00606781-I1Open ↗
08/31/2026B00606781-P1Open ↗
Showing 3 of 15 on file for this type
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST3
03/09/2022321072502Open ↗
06/16/2021340721455Open ↗
08/11/2020321568219Open ↗
▸BISFINAL1
03/08/2022321072502Open ↗
▸BISLETTERS - SUPPORTING DOCUMENTATION1
09/01/2020321072502Open ↗
▸DOB NOWDesign Commission Sign Off City Owned (Exterior Work)1
08/13/2026B00230428-I1Open ↗
▸DOB NOWDesign Commission Approval City Owned (Exterior Work)1
08/13/2026B00230428-I1Open ↗
▸Cost, Insurance & Ownership10
▸BISCOST AFFIDAVIT8
06/16/2021340721455Open ↗
06/09/2021340721455Open ↗
06/09/2021340721455Open ↗
Showing 3 of 8 on file for this type
▸BISCOST AFFIDAVIT (FINAL): PW32
03/08/2022321072502Open ↗
08/11/2020321568219Open ↗
▸Filing & Intake Forms11
▸BISADDITIONAL INFORMATION7
04/27/2021321072502Open ↗
07/22/2020321072502Open ↗
07/22/2020321072502Open ↗
Showing 3 of 7 on file for this type
▸BISEFILING COVER SHEET3
11/21/2018321072502Open ↗
11/21/2018321072502Open ↗
05/05/2017321568219Open ↗
▸BISEFILING JOB APPLICATION COVER SHEET1
03/11/2020340721455Open ↗
▸Other Documents3
▸BISSHUTOFF DAMPERS1
03/08/2022321072502Open ↗
▸BISMAINTENANCE INFORMATION1
03/08/2022321072502Open ↗
▸DOB NOWAdjoining Owners Notification1
08/13/2026B00959465-S3Open ↗