← Back
One family attached or semi-detached
1552 EAST 58 STREET
BROOKLYN · Flatlands · BIN 3236221
💬 Discuss this project
1955Year Built
1Stories
A5Building Class
R5Zoning
764 sfGross Floor Area
1Units
One family attached or semi-detached · 1,992 sf lot · 0.38 FAR built · Flood zone X500
Locations of Work
ArchitecturePlumbing
Floor 13p · 1 filing · 7 docs
Cellar5p · 2 filings · 16 docs
Site & exterior3p · 1 filing · 7 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
01/26/2024$530K—Private party → Private party$694/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
CHUN FENG, ARCHITECT204/19/2024
J&R DESIGN AND INSPECTION CORP.102/15/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
HIGH QUALITY 338603/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
HIGH QUALITY CONSTRUCTIONGeneral Contractor107/08/2026
AMERICAN STANDARD P&H CORORP.Plumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
J&R DESIGN AND INSPECTION6637204/19/2024
NKM ENGINEERING PLLC6244102/15/2024
Building Lifecycle
All (24)Filed (3)Permit Issued (2)Signed Off (2)Inspection (4)Special Inspection (13)
05/24/2024
Signed off — Alteration
FILE PLMBING WORK IN 1-FAMILY BUILDING WITH NEW BOILER AND REPLACE H.W.H. AS PER PLAN. NO CHANGE OF USE, EGRESS, OR CERTIFICATE OF OCCUPANCY.
B01002107-I1
05/24/2024
Signed off — Alteration
MINOR CONSTRUCTION WORK IN 1-FAMILY BUILDING WITH REMOVE/NEW/REPAIR PARTITION, CEILING, FLOOR, REPLACE DOORS, WINDOWS AND PAINTING AS PER PLAN. NO CHANGE OF USE, EGRESS, OR CERTIFICATE OF OCCUPANC
B01001038-I1
04/23/2024
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
04/19/2024
Filed — Alteration
FILE PLMBING WORK IN 1-FAMILY BUILDING WITH NEW BOILER AND REPLACE H.W.H. AS PER PLAN. NO CHANGE OF USE, EGRESS, OR CERTIFICATE OF OCCUPANCY.
B01002107-P1
04/19/2024
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
04/19/2024
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
04/19/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
Robert Truskosky
04/19/2024
Special inspection requirement — Energy Code Compliance Inspections
Robert Truskosky
04/19/2024
Special inspection requirement — HVAC-R and service water heating system controls
Robert Truskosky
04/19/2024
Special inspection requirement — HVAC-R and service water heating equipment
Robert Truskosky
04/19/2024
Special inspection requirement — HVAC-R and service water piping design and insulation
Robert Truskosky
04/01/2024
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
02/23/2024
Permit issued — Plumbing
B01002107-I1-PL
02/22/2024
Permit issued — General Construction
B01001038-I1-GC
02/15/2024
Filed — Alteration
FILE PLMBING WORK IN 1-FAMILY BUILDING WITH NEW BOILER AND REPLACE H.W.H. AS PER PLAN. NO CHANGE OF USE, EGRESS, OR CERTIFICATE OF OCCUPANCY.
B01002107-I1
02/15/2024
Filed — Alteration
MINOR CONSTRUCTION WORK IN 1-FAMILY BUILDING WITH REMOVE/NEW/REPAIR PARTITION, CEILING, FLOOR, REPLACE DOORS, WINDOWS AND PAINTING AS PER PLAN. NO CHANGE OF USE, EGRESS, OR CERTIFICATE OF OCCUPANC
B01001038-I1
02/05/2024
Special inspection requirement — Fenestration air leakage
NARESH MAHANGU
02/05/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
NARESH MAHANGU
02/05/2024
Special inspection requirement — Fenestration areas
NARESH MAHANGU
02/05/2024
Special inspection requirement — Fenestration and door U-factor and product ratings
NARESH MAHANGU
02/05/2024
Special inspection requirement — Energy Code Compliance Inspections
NARESH MAHANGU
02/05/2024
Special inspection requirement — Fire-Resistance Rated Construction
NARESH MAHANGU
02/05/2024
Special inspection requirement — Final
Chun Feng
02/05/2024
Special inspection requirement — Air barrier - visual inspection
NARESH MAHANGU
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offAMERICAN STANDARD P&H CORORP.02/23/2024
DOB NOWGeneral ConstructionSigned-offHIGH QUALITY CONSTRUCTION02/22/2024
Nothing on file for this building.
▾Field Inspections (DOB CAP) — 4
DateTypeResultReport
04/23/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
04/19/2024Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
04/19/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
04/01/2024Certified Gas-Gas-Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 13
DateRequirementInspectorRole
04/19/2024Fire-Resistant Penetrations and JointsRobert Truskoskyspecial
04/19/2024Energy Code Compliance InspectionsRobert Truskoskyprogress
04/19/2024HVAC-R and service water heating system controlsRobert Truskoskyenergy_progress
04/19/2024HVAC-R and service water heating equipmentRobert Truskoskyenergy_progress
04/19/2024HVAC-R and service water piping design and insulationRobert Truskoskyenergy_progress
02/05/2024Fenestration air leakageNARESH MAHANGUenergy_progress
02/05/2024Fire-Resistant Penetrations and JointsNARESH MAHANGUspecial
02/05/2024Fenestration areasNARESH MAHANGUenergy_progress
02/05/2024Fenestration and door U-factor and product ratingsNARESH MAHANGUenergy_progress
02/05/2024Energy Code Compliance InspectionsNARESH MAHANGUprogress
02/05/2024Fire-Resistance Rated ConstructionNARESH MAHANGUprogress
02/05/2024FinalChun Fengprogress
02/05/2024Air barrier - visual inspectionNARESH MAHANGUenergy_progress
▾Documents — 16 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch3
08/26/2026B01001038-I1Request digital key ↗
08/25/2026B01002107-P1Request digital key ↗
08/25/2026B01002107-I1Request digital key ↗
▸Seals & Professional Certifications10
▸DOB NOWProgress Inspector Seal & Signature5
08/24/2026B01001038-I1Open ↗
08/24/2026B01001038-I1Open ↗
08/24/2026B01001038-I1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/26/2026B01001038-I1Open ↗
08/25/2026B01002107-P1Open ↗
08/25/2026B01002107-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
08/24/2026B01001038-I1Open ↗
08/24/2026B01002107-P1Open ↗
▸Environmental & Asbestos3
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
08/26/2026B01001038-I1Open ↗
08/25/2026B01002107-I1Open ↗
08/25/2026B01002107-P1Open ↗