← Back
Over six families without stores
1554 NEW YORK AVE
BROOKLYN · East Flatbush-Farragut · BIN 3429051
💬 Discuss this project
0Year Built
5Stories
C1Building Class
R6Zoning
0 sfGross Floor Area
9Units
Rent Stabilized0 Open ViolationsFDNY Report ↗
Over six families without stores · Owner of record: 1554-1556 NY AVE LLC · 2,050 sf lot · 0 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbing
Roof1p · 1 filing · 20 docs
Penthouse2p · 1 filing · 20 docs
Floor 33p · 1 filing · 20 docs
Floor 21p · 1 filing · 20 docs
Floor 12p · 1 filing · 20 docs
Cellar2p · 1 filing · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
RE-BRICK CONSTRUCTION703/22/2026
RED BRICK PROPERTY MNGMT103/22/2026
MANAGEMENT CREW303/21/2026
1554-1556 NY AVE LLC103/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
CHOSEN MEP, CORP.508/19/2022
KNF SERVICES CROP105/13/2022
ENTHINK ENGINEERS LLC204/04/2022
NIKOLAI KATZ ARCHITECT104/16/2021
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
EXPRESS FILING INC1203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
RED BRICK PROPERTY MNGMTGeneral Contractor1803/22/2026
RE-BRICK CONSTRUCTION INCGeneral Contractor303/21/2026
MPI PLUMBING CORPPlumbing307/08/2026
PRIME PIPING & HEATING INFire Protection107/08/2026
A M B MECHANICALPlumbing103/22/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
HRF SERVICES CORP5616508/19/2022
Building Lifecycle
All (59)Filed (9)Permit Issued (8)Signed Off (7)Violation (2)Inspection (8)Special Inspection (25)
05/23/2026
Violation issued (HPD, closed)
B
04/07/2023
Inspection — Certified Sprinkler-SP-Fixtures-Finish
Certified
View inspection ↗
04/05/2023
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
04/05/2023
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
01/12/2023
Signed off — Alteration
SPRINKLER SPECIFICATIONS FILED IN CONJUNCTION WITH NB JOB #321600095
B00492964-I1
01/12/2023
Signed off — Alteration
SPRINKLER SPECIFICATIONS FILED IN CONJUNCTION WITH NB JOB #321600095
B00492964-S3
01/03/2023
Signed off — Alteration
SPRINKLER SPECIFICATIONS FILED IN CONJUNCTION WITH NB JOB #321600095
B00492964-S1
12/19/2022
Signed off — Alteration
SPRINKLER SPECIFICATIONS FILED IN CONJUNCTION WITH NB JOB #321600095
B00492964-S2
12/19/2022
Signed off — Alteration
Fiing for tempoary supported scaffolding. No change in use, egress or occupancy.
B00737258-I1
12/01/2022
Signed off — Alteration
INSTALLATION OF TEMPORARY CONSTRUCTION FENCE
B00505085-I1
10/28/2022
Signed off — Alteration
B00692291-I1
08/23/2022
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
08/22/2022
Special inspection requirement — Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation
FAHAD FATEH
08/22/2022
Special inspection requirement — HVAC-R and service water piping design and insulation
FAHAD FATEH
08/22/2022
Special inspection requirement — HVAC-R and service water heating system controls
FAHAD FATEH
08/22/2022
Special inspection requirement — Maintenance information
FAHAD FATEH
08/22/2022
Special inspection requirement — HVAC-R and service water heating equipment
FAHAD FATEH
08/22/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
FAHAD FATEH
08/19/2022
Filed — Alteration
SPRINKLER SPECIFICATIONS FILED IN CONJUNCTION WITH NB JOB #321600095
B00492964-P1
07/12/2022
Permit issued — Sprinklers
B00492964-S2-EW-SP
07/08/2022
Inspection — Certified Storm Drainage-ST-Piping-Underground
Certified
View inspection ↗
07/05/2022
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
06/22/2022
Inspection — Pass-Final PL - Up to 9 Requested Floors
Pass
View inspection ↗
05/28/2022
Permit issued — Construction Fence
B00505085-I1-FN
05/26/2022
Permit issued — Mechanical Systems
B00492964-I1-MS
05/16/2022
Permit issued — Supported Scaffold
B00737258-I1-SF
05/13/2022
Filed — Alteration
Fiing for tempoary supported scaffolding. No change in use, egress or occupancy.
B00737258-I1
04/15/2022
Violation issued (ECB, closed)
Construction
04/11/2022
Inspection — Pass-Final PL - Underground
Pass
View inspection ↗
04/05/2022
Special inspection requirement — Final
Sunil Saigal
04/04/2022
Filed — Alteration
B00692291-P1
03/11/2022
Permit issued — Plumbing
B00492964-S1-PL
03/10/2022
Permit issued — Sidewalk Shed
B00692291-I1-SH
03/09/2022
Filed — Alteration
B00692291-I1
01/05/2022
Permit issued — Earth Work
B00492964-S3-GC-CX
10/13/2021
Permit issued — Construction Fence
B00505085-I1-FN
05/04/2021
Filed — Alteration
SPRINKLER SPECIFICATIONS FILED IN CONJUNCTION WITH NB JOB #321600095
B00492964-S3
05/02/2021
Special inspection requirement — Footing and Foundation
FAHAD FATEH
05/02/2021
Special inspection requirement — Final
FAHAD FATEH
05/02/2021
Special inspection requirement — Structural Steel - Details
FAHAD FATEH
05/02/2021
Special inspection requirement — Structural Cold-Formed Steel
FAHAD FATEH
05/02/2021
Special inspection requirement — Masonry
FAHAD FATEH
05/02/2021
Special inspection requirement — Concrete - Cast-In-Place
FAHAD FATEH
04/26/2021
Filed — Alteration
SPRINKLER SPECIFICATIONS FILED IN CONJUNCTION WITH NB JOB #321600095
B00492964-S2
04/26/2021
Special inspection requirement — Seismic Isolation Systems
FAHAD FATEH
04/26/2021
Special inspection requirement — Sprinkler Systems
FAHAD FATEH
04/26/2021
Special inspection requirement — Fire-Resistant Penetrations and Joints
FAHAD FATEH
04/16/2021
Filed — Alteration
INSTALLATION OF TEMPORARY CONSTRUCTION FENCE
B00505085-I1
04/14/2021
Filed — Alteration
SPRINKLER SPECIFICATIONS FILED IN CONJUNCTION WITH NB JOB #321600095
B00492964-S1
04/12/2021
Filed — Alteration
SPRINKLER SPECIFICATIONS FILED IN CONJUNCTION WITH NB JOB #321600095
B00492964-I1
04/08/2021
Special inspection requirement — Fire-Resistance Rated Construction
FAHAD FATEH
04/08/2021
Special inspection requirement — Fire-Resistant Penetrations and Joints
FAHAD FATEH
04/08/2021
Special inspection requirement — Heating Systems
FAHAD FATEH
04/08/2021
Special inspection requirement — HVAC-R and service water heating equipment
FAHAD FATEH
04/08/2021
Special inspection requirement — HVAC-R and service water heating system controls
FAHAD FATEH
04/08/2021
Special inspection requirement — Electrical motors and elevators
FAHAD FATEH
04/08/2021
Special inspection requirement — HVAC-R and service water piping design and insulation
FAHAD FATEH
03/25/2021
Special inspection requirement — Final
FAHAD FATEH
03/25/2021
Special inspection requirement — Mechanical Systems
FAHAD FATEH
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSprinklersSigned-offA M B MECHANICAL INC07/12/2022
DOB NOWConstruction FenceSigned-offRED BRICK PROPERTY MNGMT05/28/2022
DOB NOWMechanical SystemsSigned-offRED BRICK PROPERTY MNGMT05/26/2022
DOB NOWSupported ScaffoldSigned-offRED BRICK PROPERTY MNGMT05/16/2022
DOB NOWPlumbingSigned-offYG SERVICES INC03/11/2022
DOB NOWSidewalk ShedSigned-offRE-BRICK CONSTRUCTION INC03/10/2022
DOB NOWEarth WorkSigned-offRED BRICK PROPERTY MNGMT01/05/2022
DOB NOWConstruction FenceSigned-offRED BRICK PROPERTY MNGMT10/13/2021
BIS—ISSUEDRED BRICK PROPERTY MNGMT05/25/2022
BIS—ISSUEDRED BRICK PROPERTY MNGMT01/20/2022
3 projects · most recent 01/16/2023
General Wiring
FiledStatusContractorScope
01/16/2023CompleteFOSTER ELEC'L SVC., INC.—
12/05/2022CompleteFOSTER ELEC'L SVC., INC.General Wiring
03/11/2022CompleteRICHARD NEU—
▾Field Inspections (DOB CAP) — 8
DateTypeResultReport
04/07/2023Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
04/05/2023Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
04/05/2023Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
08/23/2022Pass-Final PL - Up to 3 Requested FloorsPassView ↗
07/08/2022Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
07/05/2022Pass-Final PL - Up to 3 Requested FloorsPassView ↗
06/22/2022Pass-Final PL - Up to 9 Requested FloorsPassView ↗
04/11/2022Pass-Final PL - UndergroundPassView ↗
▾Special Inspection Requirements (DOB NOW) — 25
DateRequirementInspectorRole
08/22/2022Private On-Site Storm Water Disposal Systems-, and Detention Facilities, InstallationFAHAD FATEHspecial
08/22/2022HVAC-R and service water piping design and insulationFAHAD FATEHenergy_progress
08/22/2022HVAC-R and service water heating system controlsFAHAD FATEHenergy_progress
08/22/2022Maintenance informationFAHAD FATEHenergy_progress
08/22/2022HVAC-R and service water heating equipmentFAHAD FATEHenergy_progress
08/22/2022Fire-Resistant Penetrations and JointsFAHAD FATEHspecial
04/05/2022FinalSunil Saigalprogress
05/02/2021Footing and FoundationFAHAD FATEHprogress
05/02/2021FinalFAHAD FATEHprogress
05/02/2021Structural Steel - DetailsFAHAD FATEHspecial
05/02/2021Structural Cold-Formed SteelFAHAD FATEHspecial
05/02/2021MasonryFAHAD FATEHspecial
05/02/2021Concrete - Cast-In-PlaceFAHAD FATEHspecial
04/26/2021Seismic Isolation SystemsFAHAD FATEHspecial
04/26/2021Sprinkler SystemsFAHAD FATEHspecial
04/26/2021Fire-Resistant Penetrations and JointsFAHAD FATEHspecial
04/08/2021Fire-Resistance Rated ConstructionFAHAD FATEHprogress
04/08/2021Fire-Resistant Penetrations and JointsFAHAD FATEHspecial
04/08/2021Heating SystemsFAHAD FATEHspecial
04/08/2021HVAC-R and service water heating equipmentFAHAD FATEHenergy_progress
04/08/2021HVAC-R and service water heating system controlsFAHAD FATEHenergy_progress
04/08/2021Electrical motors and elevatorsFAHAD FATEHenergy_progress
04/08/2021HVAC-R and service water piping design and insulationFAHAD FATEHenergy_progress
03/25/2021FinalFAHAD FATEHprogress
03/25/2021Mechanical SystemsFAHAD FATEHspecial
▾Documents — 100 on file (BIS + DOB NOW)
▸Plans & Drawings9
▸DOB NOWPlans/Sketch9
09/01/2026B00505085-I1Request digital key ↗
09/01/2026B00492964-S3Request digital key ↗
09/01/2026B00492964-I1Request digital key ↗
Showing 3 of 9 on file for this type
▸Applications & Permits8
▸BISPLAN / WORK APPROVAL APPLICATION5
01/25/2023321600095Open ↗
01/23/2023321600095Open ↗
12/06/2022321600095Open ↗
Showing 3 of 5 on file for this type
▸BISWORK PERMIT APPLICATION2
01/21/2022321600095Open ↗
01/06/2022321600095Open ↗
▸BISCERTIFICATE OF OCCUPANCY: APPLICATION1
07/12/2022321600095Open ↗
▸Zoning, Tax Lot & Property Records7
▸BISTAX LOT: TENTATIVE LOT NUMBER ISSUED1
05/24/2021321600095Open ↗
▸BISZONING EXHIBIT III:DESC. & OWNRSHP.STMNT1
05/24/2021321600095Open ↗
▸BISVERIFY TAX LOT1
01/16/2023321600095Open ↗
▸BISADDRESS: NEW HOUSE NUMBER APPROVED1
05/24/2021321600095Open ↗
▸BISCO OBJ: VERIFY ADDRESS-TOPO STAMP1
12/20/2022321600095Open ↗
▸BISZONING DIAGRAM1
05/24/2021321600095Open ↗
▸BISZONING EXHIBIT I: CERTIFICATION1
05/24/2021321600095Open ↗
▸Seals & Professional Certifications19
▸DOB NOWDPL-1: Design Professional Seal & Signature9
09/01/2026B00505085-I1Open ↗
09/01/2026B00492964-S1Open ↗
09/01/2026B00492964-S3Open ↗
Showing 3 of 9 on file for this type
▸DOB NOWProgress Inspector Seal & Signature5
08/30/2026B00492964-I1Open ↗
08/30/2026B00492964-I1Open ↗
08/28/2026B00492964-S1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature4
08/30/2026B00492964-I1Open ↗
08/28/2026B00492964-S1Open ↗
08/26/2026B00492964-S2Open ↗
Showing 3 of 4 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION1
01/06/2022321600095Open ↗
▸Trade Schedules & Equipment6
▸BISDEP SANITARY SEWER CERTIFICATION (HCP/SCP)2
12/06/2022321600095Open ↗
05/24/2021321600095Open ↗
▸BISFA - FDNY APPROVAL : FD-FAA1
01/12/2023321600095Open ↗
▸BISHVAC & SERVICE WATER HEATING EQUIPMENT1
01/02/2023321600095Open ↗
▸BISHVAC & SERVICE WATER HEATING SYSTEM CONTROLS1
01/02/2023321600095Open ↗
▸BISDEP STORMWATER SEWER CERTIFICATION (HCP/SCP)1
05/24/2021321600095Open ↗
▸Safety & Tenant Protection3
▸BISSTREET TREE CHECKLIST2
02/24/2023321600095Open ↗
05/24/2021321600095Open ↗
▸BISSTREET TREE SIGNOFF1
01/17/2023321600095Open ↗
▸Energy Compliance15
▸DOB NOWEN2: As Built Energy Analysis.2
08/13/2026B00492964-S1Open ↗
08/13/2026B00492964-I1Open ↗
▸BISAIR SEALING AND INSULATION - VISUAL1
01/02/2023321600095Open ↗
▸BISINTERIOR LIGHTING POWER1
01/02/2023321600095Open ↗
▸BISFENESTRATION U-FACTOR & PRODUCT RATING1
01/02/2023321600095Open ↗
▸BISFENESTRATION AREAS1
01/02/2023321600095Open ↗
▸BISAS-BUILT ENERGY ANALYSIS (EN2)1
01/02/2023321600095Open ↗
▸BISINSULATION PLACEMENT & R VALUES1
01/02/2023321600095Open ↗
▸BISLIGHTING IN DWELLING UNITS1
01/02/2023321600095Open ↗
▸BISLIGHTING CONTROLS1
01/02/2023321600095Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS1
01/06/2022321600095Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY1
05/24/2021321600095Open ↗
▸BISELECTRICAL ENERGY CONSUMPTION1
01/02/2023321600095Open ↗
▸BISEXTERIOR LIGHTING POWER1
01/02/2023321600095Open ↗
▸BISFENESTRATION AIR LEAKAGE1
01/02/2023321600095Open ↗
▸Inspections & Test Reports15
▸BISTECHNICAL REPORT: RESPONSIBILITY3
01/12/2023321600095Open ↗
01/12/2023321600095Open ↗
05/24/2021321600095Open ↗
▸BISDEMOLITION (DM) JOB SIGNOFF1
01/12/2023321600095Open ↗
▸BISCONCRETE - CAST-IN-PLACE1
01/02/2023321600095Open ↗
▸BISSUBSURFACE / SOILS INVESTIGATION (BORINGS/TEST PITS)1
01/06/2023321600095Open ↗
▸BISTR3: CONCRETE DESIGN MIX TECHNICAL REPORT1
01/06/2022321600095Open ↗
▸BISFIRE-RESISTANT PENETRATIONS AND JOINTS (FIRESTOP)1
01/02/2023321600095Open ↗
▸BISFIRE-RESISTIVE RATED CONSTRUCTION1
01/02/2023321600095Open ↗
▸BISPOST-INSTALLED ANCHORS1
01/02/2023321600095Open ↗
▸BISSOIL REPORT1
05/24/2021321600095Open ↗
▸BISTECHNICAL REPORT: CONCRETE/TEST CYLINDER1
01/30/2023321600095Open ↗
▸BISTECHNICAL REPORT: SOIL INSPECTION1
05/24/2021321600095Open ↗
▸BISTR2: CONCRETE TEST CYLINDERS TECHNICAL REPORT1
01/06/2022321600095Open ↗
▸DOB NOWConcrete Testing Exception Report1
08/13/2026B00492964-S3Open ↗
▸Approvals, Objections & Sign-offs3
▸BISSCHEDULE A - OCCUPANCY / USE3
01/25/2023321600095Open ↗
12/06/2022321600095Open ↗
05/20/2021321600095Open ↗
▸Cost, Insurance & Ownership4
▸BISAcord 25 (Acord Certificate of Liability Insurance)2
01/21/2022321600095Open ↗
01/06/2022321600095Open ↗
▸BISPROJECT-SPECIFIC GL INSURANCE1
01/21/2022321600095Open ↗
▸BISPROJECT SPECIFIC GENERAL LIABILITY INSURANCE1
01/06/2022321600095Open ↗
▸Filing & Intake Forms4
▸BISADDITIONAL INFORMATION3
02/24/2023321600095Open ↗
01/30/2023321600095Open ↗
01/30/2023321600095Open ↗
▸BISEFILING COVER SHEET1
02/19/2021321600095Open ↗
▸Other Documents7
▸BISSHUTOFF DAMPERS1
01/02/2023321600095Open ↗
▸BISSUSTAINABLE ROOF ZONE FORM1
05/24/2021321600095Open ↗
▸BISMAINTENANCE INFORMATION1
01/02/2023321600095Open ↗
▸BISHVAC & SERVICE WATER PIPING DESIGN AND INSULATION1
01/02/2023321600095Open ↗
▸BISPROTECTION OF EXPOSED FOUNDATION INSULATION1
01/02/2023321600095Open ↗
▸BISPLOT DIAGRAM1
05/24/2021321600095Open ↗
▸DOB NOWAdjoining Owners Notification1
08/13/2026B00492964-S3Open ↗