← Back
Zoned residential, not Manhattan
1555 51 STREET
BROOKLYN · BIN 3129362
💬 Discuss this project
0Year Built
—Stories
V0Building Class
R6Zoning
0 sfGross Floor Area
0Units
0 Open ViolationsFDNY Report ↗
Zoned residential, not Manhattan · Owner of record: 1555 51 LLC · 3,005 sf lot · 0 FAR built · Flood zone X
Locations of Work
ArchitectureMechanicalPlumbingFire Protection
Permit Issued — active, not yet Signed-off
RoofUnder Construction25p · 1 filing · 20 docs
PenthouseUnder Construction25p · 1 filing · 20 docs
Floor 4Under Construction25p · 1 filing · 20 docs
Floor 3Under Construction25p · 1 filing · 20 docs
Floor 2Under Construction25p · 1 filing · 20 docs
Floor 1Under Construction24p · 1 filing · 20 docs
CellarUnder Construction31p · 2 filings · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
OWNERS REP507/08/2026
KAUFMAN GROUP203/22/2026
CORE SCAFFOLD SYSTEMS103/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
04/02/2025$900K—— → —— not available
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
ASHER ARCHITECT802/11/2026
EYAL LEVITT ARCHITECT PC202/03/2026
PAUL PERDEK, PROF. ENG. PLLC206/26/2025
MEY ASSOCIATES104/24/2025
R & O ENGINEERING311/18/2024
RALPH P. ALBANESE, ARCHITECT111/29/2022
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
AE DESIGN SOLUTION403/21/2026
ERETZ BUILDERS ASSISTANCE.2403/21/2026
ASAP ASSOCIATES CORP203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
KAUFMAN GROUP INCGeneral Contractor807/08/2026
CORE SCAFFOLD SYSTEMS INC.General Contractor207/08/2026
PSG CONSTRUCTION CO.,INCGeneral Contractor203/21/2026
SOLAS ELECTRICAL CORPElectrical103/22/2026
PRIME PIPING & HEATING INFire Protection107/08/2026
PRIME PIPING & HEATING INPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
HRF SERVICES CORP5616902/11/2026
SHAHRISH SHUVO ENGINEERIN8524302/03/2026
Building Lifecycle
All (171)Filed (17)Permit Issued (11)Signed Off (11)Violation (8)Inspection (14)Objection (80)Special Inspection (30)
06/04/2026
Signed off — New Building
NEW 4 STORY AND CELLAR / PENTHOUSE BUILDING
B01054373-I1
03/13/2026
Signed off — New Building
NEW 4 STORY AND CELLAR / PENTHOUSE BUILDING
B01054373-S7
03/13/2026
Inspection — No Access-Final PL - Up to 3 Requested Floors
No Access
View inspection ↗
03/05/2026
Inspection — Fail-Final PL - Up to 3 Requested Floors
Fail
View inspection ↗
02/24/2026
Inspection — No Access-Final PL - Up to 3 Requested Floors
No Access
View inspection ↗
02/23/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Shahrish Shuvo
02/23/2026
Special inspection requirement — Sprinkler Systems
Shahrish Shuvo
02/11/2026
Filed — New Building
NEW 4 STORY AND CELLAR / PENTHOUSE BUILDING
B01054373-P5
02/11/2026
Objection resolved — Addressed
02/11/2026
Special inspection requirement — Fenestration and door U-factor and product ratings
FAHAD FATEH
02/11/2026
Special inspection requirement — Energy Code Compliance Inspections
FAHAD FATEH
02/11/2026
Special inspection requirement — Lighting in dwelling units
FAHAD FATEH
02/11/2026
Special inspection requirement — Fenestration air leakage
FAHAD FATEH
02/11/2026
Special inspection requirement — Lighting controls
FAHAD FATEH
02/11/2026
Special inspection requirement — Exterior lighting power
FAHAD FATEH
02/11/2026
Special inspection requirement — Maintenance information
FAHAD FATEH
02/11/2026
Special inspection requirement — Fenestration areas
FAHAD FATEH
02/11/2026
Special inspection requirement — Interior lighting power
FAHAD FATEH
02/11/2026
Special inspection requirement — Metering
FAHAD FATEH
02/11/2026
Special inspection requirement — Air barrier - visual inspection
FAHAD FATEH
02/11/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
FAHAD FATEH
02/11/2026
Special inspection requirement — Fire-Resistance Rated Construction
FAHAD FATEH
02/11/2026
Special inspection requirement — Insulation placement and R values
FAHAD FATEH
02/09/2026
Objection raised — Scope
02/05/2026
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
02/03/2026
Filed — New Building
NEW 4 STORY AND CELLAR / PENTHOUSE BUILDING
B01054373-P4
01/30/2026
Signed off — Alteration
Plumbing work for New Building filed in conjunction with GC #B01054373-I1
B01200379-I1
01/13/2026
Inspection — Certified Sprinkler-SP-Fixtures-Finish
Certified
View inspection ↗
01/09/2026
Inspection — Certified Sprinkler (SP) - Booster Pump Test
Certified
View inspection ↗
01/09/2026
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
12/19/2025
Signed off — New Building
NEW 4 STORY AND CELLAR / PENTHOUSE BUILDING
B01054373-S3
12/17/2025
Signed off — Alteration
INSTALLING 8'-0" HIGH CONSTRUCTION FENCE
B01208120-I1
12/17/2025
Signed off — New Building
NEW 4 STORY AND CELLAR / PENTHOUSE BUILDING
B01054373-S5
12/15/2025
Special inspection requirement — Final
Shahrish Shuvo
12/15/2025
Special inspection requirement — Mechanical Systems
Shahrish Shuvo
12/15/2025
Special inspection requirement — Duct leakage testing, insulation and design
Shahrish Shuvo
12/15/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Shahrish Shuvo
12/15/2025
Special inspection requirement — HVAC-R and service water heating equipment
Shahrish Shuvo
12/15/2025
Special inspection requirement — HVAC-R and service water heating system controls
Shahrish Shuvo
12/15/2025
Special inspection requirement — Shutoff dampers
Shahrish Shuvo
12/15/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
Shahrish Shuvo
12/02/2025
Filed — New Building
NEW 4 STORY AND CELLAR / PENTHOUSE BUILDING
B01054373-P3
12/02/2025
Special inspection requirement — Shutoff dampers
FAHAD FATEH
12/02/2025
Special inspection requirement — HVAC-R and service water heating system controls
FAHAD FATEH
12/02/2025
Special inspection requirement — Duct leakage testing, insulation and design
FAHAD FATEH
12/02/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
FAHAD FATEH
12/02/2025
Special inspection requirement — HVAC-R and service water heating equipment
FAHAD FATEH
12/02/2025
Special inspection requirement — Final
FAHAD FATEH
11/24/2025
Signed off — Alteration
INSTALLATION OF TEMPORARY PIPE SCAFFOLD AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B01247679-I1
11/24/2025
Signed off — Alteration
B01241313-I1
10/30/2025
Signed off — New Building
NEW 4 STORY AND CELLAR / PENTHOUSE BUILDING
B01054373-S2
10/28/2025
Violation issued (ECB, closed)
Construction
10/06/2025
Inspection — Certified Storm Drainage-ST-Piping-Roughing
Certified
View inspection ↗
09/02/2025
Filed — New Building
NEW 4 STORY AND CELLAR / PENTHOUSE BUILDING
B01054373-P2
08/06/2025
Violation issued (ECB, closed)
Construction
07/15/2025
Inspection — Certified Storm Drainage-ST-Piping-Underground
Certified
View inspection ↗
07/15/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
07/03/2025
Permit issued — Mechanical Systems
B01054373-S5-MS
06/27/2025
Permit issued — Supported Scaffold
B01247679-I1-SF
06/27/2025
Inspection — Certified Storm Drainage-ST-Piping-Underground
Certified
View inspection ↗
Latest 60 of 171 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsSigned-offKAUFMAN GROUP INC07/03/2025
DOB NOWSupported ScaffoldSigned-offCORE SCAFFOLD SYSTEMS INC06/27/2025
DOB NOWSidewalk ShedSigned-offCORE SCAFFOLD SYSTEMS INC06/17/2025
DOB NOWSprinklersSigned-offA M B MECHANICAL INC06/06/2025
DOB NOWPlumbingSigned-offPRIME PIPING & HEATING IN06/04/2025
DOB NOWStructuralSigned-offKAUFMAN GROUP INC05/09/2025
DOB NOWGeneral ConstructionPermit IssuedKAUFMAN GROUP INC05/09/2025
DOB NOWFoundationSigned-offKAUFMAN GROUP INC05/08/2025
DOB NOWSupport of ExcavationSigned-offKAUFMAN GROUP INC05/08/2025
DOB NOWConstruction FenceSigned-offKAUFMAN GROUP INC04/29/2025
DOB NOWGeneral ConstructionSigned-offPSG CONSTRUCTION CO.,INC05/02/2023
BIS—ISSUEDBEST BUY DEMO INC12/14/2012
BISEQISSUEDBEST BUY DEMO INC12/12/2012
BISEQISSUEDMARGE NY INC09/13/2012
1 project · most recent 02/11/2026
Heating and Air Conditioning Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
02/11/2026Signed-offKAUFMAN GROUP INCHeating and Air Conditioning Systems, Ventilation Systems
Heat / Cool
Mitsubishi Electric MXZ-SM60NL 60,000 BTU · Condensing Unit ×10
MXZ-SM48NL 48,000 BTU · Condensing Unit ×2
Ventilation
Nutone 126313 50 CFM · Exhaust Fan ×14
Delta Breeze ITG100 100 CFM · Exhaust Fan ×2
1 project · most recent 02/11/2026
Sprinkler System
FiledStatusContractorScope
02/11/2026Signed-offPRIME PIPING & HEATING INSprinkler System
4 projects · most recent 08/11/2025
General Wiring
FiledStatusContractorScope
08/11/2025CompletePOWER DIRECT ELECTRIC INCGeneral Wiring
07/03/2025CompletePOWER DIRECT ELECTRIC INC—
06/25/2025CompleteSOLAS ELECTRICAL CORP—
05/27/2025CompletePOWER DIRECT ELECTRIC INC—
1 project · most recent 02/11/2026
Steel Concrete
FiledStatusContractorScope
02/11/2026Signed-offKAUFMAN GROUP INCSteel, Concrete
▾Field Inspections (DOB CAP) — 14
DateTypeResultReport
03/13/2026No Access-Final PL - Up to 3 Requested FloorsNo AccessView ↗
03/05/2026Fail-Final PL - Up to 3 Requested FloorsFailView ↗
02/24/2026No Access-Final PL - Up to 3 Requested FloorsNo AccessView ↗
02/05/2026Pass-Final CND-Occupancy InspectionPassView ↗
01/13/2026Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
01/09/2026Certified Sprinkler (SP) - Booster Pump TestCertifiedView ↗
01/09/2026Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
10/06/2025Certified Storm Drainage-ST-Piping-RoughingCertifiedView ↗
07/15/2025Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
07/15/2025Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
06/27/2025Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
06/27/2025Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
06/06/2025Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
06/06/2025Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 69
DateRequirementInspectorRole
02/23/2026Sprinkler SystemsShahrish Shuvospecial
02/23/2026Fire-Resistant Penetrations and JointsShahrish Shuvospecial
02/11/2026Lighting controlsFAHAD FATEHenergy_progress
02/11/2026Fenestration air leakageFAHAD FATEHenergy_progress
02/11/2026Air barrier - visual inspectionFAHAD FATEHenergy_progress
02/11/2026Fire-Resistant Penetrations and JointsFAHAD FATEHspecial
02/11/2026Energy Code Compliance InspectionsFAHAD FATEHprogress
02/11/2026Fire-Resistance Rated ConstructionFAHAD FATEHprogress
02/11/2026Fenestration areasFAHAD FATEHenergy_progress
02/11/2026Interior lighting powerFAHAD FATEHenergy_progress
02/11/2026Insulation placement and R valuesFAHAD FATEHenergy_progress
02/11/2026Fenestration and door U-factor and product ratingsFAHAD FATEHenergy_progress
02/11/2026Exterior lighting powerFAHAD FATEHenergy_progress
02/11/2026Lighting in dwelling unitsFAHAD FATEHenergy_progress
02/11/2026Maintenance informationFAHAD FATEHenergy_progress
02/11/2026MeteringFAHAD FATEHenergy_progress
12/15/2025Fire-Resistant Penetrations and JointsShahrish Shuvospecial
12/15/2025HVAC-R and service water heating system controlsShahrish Shuvoenergy_progress
12/15/2025HVAC-R and service water piping design and insulationShahrish Shuvoenergy_progress
12/15/2025Shutoff dampersShahrish Shuvoenergy_progress
12/15/2025HVAC-R and service water heating equipmentShahrish Shuvoenergy_progress
12/15/2025Duct leakage testing, insulation and designShahrish Shuvoenergy_progress
12/15/2025FinalShahrish Shuvoprogress
12/15/2025Mechanical SystemsShahrish Shuvospecial
12/02/2025Fire-Resistant Penetrations and JointsFAHAD FATEHspecial
Latest 25 of 69.
▾Documents — 134 on file (BIS + DOB NOW)
▸Plans & Drawings17
▸DOB NOWPlans/Sketch17
08/21/2026B01208120-I1Request digital key ↗
08/21/2026B01200379-I1Request digital key ↗
08/21/2026B01200379-P2Request digital key ↗
Showing 3 of 17 on file for this type
▸Applications & Permits8
▸BISPLAN / WORK APPROVAL APPLICATION4
12/01/2012320549000Open ↗
09/14/2012320584471Open ↗
08/28/2012320549000Open ↗
Showing 3 of 4 on file for this type
▸BISWORK PERMIT APPLICATION2
12/20/2012320549000Open ↗
09/14/2012320584471Open ↗
▸BISBPP-5 - Authorization to the Department of Transportation1
09/05/2025340919876Open ↗
▸BISPLAN - WORK & PERMITS - SUPPPORTING DOCUMENTATION1
12/23/2025320584471Open ↗
▸Zoning, Tax Lot & Property Records12
▸DOB NOWHouse Number Verification: TOPO Stamp4
08/15/2026B01054373-P1Open ↗
08/15/2026B01054373-I1Open ↗
08/13/2026B01054373-P2Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWZoning Exhibit form (1-5)4
08/15/2026B01054373-P1Open ↗
08/15/2026B01054373-I1Open ↗
08/13/2026B01054373-P5Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWZD1: DOB Zoning Diagram4
08/15/2026B01054373-P1Open ↗
08/15/2026B01054373-I1Open ↗
08/13/2026B01054373-P2Open ↗
Showing 3 of 4 on file for this type
▸Seals & Professional Certifications44
▸DOB NOWDPL-1: Design Professional Seal & Signature17
08/21/2026B01208120-I1Open ↗
08/21/2026B01200379-P2Open ↗
08/21/2026B01200379-I1Open ↗
Showing 3 of 17 on file for this type
▸DOB NOWProgress Inspector Seal & Signature12
09/18/2026B01054373-P2Open ↗
09/18/2026B01054373-P2Open ↗
08/31/2026B01054373-P1Open ↗
Showing 3 of 12 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature9
09/18/2026B01054373-P2Open ↗
09/06/2026B01200379-I1Open ↗
08/31/2026B01054373-P1Open ↗
Showing 3 of 9 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY-CERTIFICATION3
02/20/2013320549000Open ↗
09/14/2012320584471Open ↗
08/28/2012320549000Open ↗
▸BISAPPLICANT OWNER SIGNATURE1
09/05/2025340919876Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
09/14/2012320584471Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM1
09/14/2012320584471Open ↗
▸Trade Schedules & Equipment4
▸DOB NOWDEP: Sewer Certification (Sanitary/Storm)4
08/15/2026B01054373-P1Open ↗
08/15/2026B01054373-I1Open ↗
08/13/2026B01054373-P5Open ↗
Showing 3 of 4 on file for this type
▸Safety & Tenant Protection11
▸DOB NOWStreet Tree Checklist4
08/18/2026B01054373-P5Open ↗
08/18/2026B01054373-P2Open ↗
08/15/2026B01054373-P1Open ↗
Showing 3 of 4 on file for this type
▸BISBPP: STREET TREES SITE PLAN1
09/05/2025340919876Open ↗
▸BISSTREET TREE CHECKLIST1
09/05/2025340919876Open ↗
▸BISSTREET TREES: RECEIPT OF STREET TREES SITE PLAN1
09/05/2025340919876Open ↗
▸BISDEMOLITION SUBMITTAL CERTIFICATION FORM1
08/28/2012320549000Open ↗
▸DOB NOWParks Department Acknowledgment Letter for Street Trees Plan1
08/15/2026B01054373-I1Open ↗
▸DOB NOWStreet Trees Site Plan1
08/15/2026B01054373-I1Open ↗
▸DOB NOWStreet Tree Sign Off1
08/15/2026B01054373-I1Open ↗
▸Environmental & Asbestos1
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
12/20/2012320549000Open ↗
▸Inspections & Test Reports2
▸BISTECHNICAL REPORT: RESPONSIBILITY2
12/19/2025320584471Open ↗
12/19/2025320584471Open ↗
▸Approvals, Objections & Sign-offs13
▸BISLETTERS - SUPPORTING DOCUMENTATION8
12/20/2012320549000Open ↗
12/20/2012320549000Open ↗
12/20/2012320549000Open ↗
Showing 3 of 8 on file for this type
▸BISADMINISTRATIVE OBJECTIONS2
09/14/2012320584471Open ↗
08/28/2012320549000Open ↗
▸BISBPP-8 - Request Items for Builders Pavement Plan Signoff1
02/24/2026340919876Open ↗
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
12/23/2025320584471Open ↗
▸DOB NOWFee Exempt Supporting Document - DOF ACRIS report or BIB letter1
08/13/2026B08039415-I1Open ↗
▸Cost, Insurance & Ownership1
▸BISCOST AFFIDAVIT1
09/14/2012320584471Open ↗
▸Filing & Intake Forms3
▸BISEFILING COVER SHEET1
09/14/2012320584471Open ↗
▸BISEFILING JOB APPLICATION COVER SHEET1
09/05/2025340919876Open ↗
▸BISBPP: CHECKLIST IN LIEU OF PLANS-ALT31
09/05/2025340919876Open ↗
▸Other Documents18
▸BISBPP - SUPPORTING DOCUMENTATION4
09/05/2025340919876Open ↗
09/05/2025340919876Open ↗
09/05/2025340919876Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWProperty Ownership Certification4
08/18/2026B01054373-P2Open ↗
08/18/2026B01054373-P5Open ↗
08/15/2026B01054373-P1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone4
08/15/2026B01054373-P1Open ↗
08/15/2026B01054373-I1Open ↗
08/13/2026B01054373-P5Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWSite Survey: Initial4
08/15/2026B01054373-P1Open ↗
08/15/2026B01054373-I1Open ↗
08/13/2026B01054373-P2Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWFinal Survey1
08/15/2026B01054373-I1Open ↗
▸DOB NOWAdjoining Owners Notification1
08/13/2026B01054373-S1Open ↗