← Back
One story retail building
1555 FLATBUSH AVENUE
BROOKLYN · BIN 3205909
💬 Discuss this project
1931Year Built
1Stories
K1Building Class
C4-4AZoning
11,580 sfGross Floor Area
5Units
14 Open Violations 12 unresolved · 2 paperwork only ▸FDNY Report ↗
One story retail building · Owner of record: FALSONS RLTY CORP · 13,951 sf lot · 0.83 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralElectricalMechanicalPlumbingFire ProtectionGeneral
Permit Issued — active, not yet Signed-off
RoofUnder Construction8p · 3 filings · 20 docs
Floor 1Under Construction28p · 5 filings · 20 docs
CellarUnder Construction16p · 1 filing · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
MUNICIPAL CREDIT UNION107/22/2026
NFS786 CORP503/22/2026
AGI303/22/2026
FALSONS RLTY CORP. JOSEPH1703/22/2026
SUBWAY203/21/2026
FOOTLOCKER103/21/2026
FALCONS REALTY403/21/2026
FALLSONS REALTY903/21/2026
ER REALTY203/21/2026
FALSONS REALTY703/21/2026
▾Design Consultants (Architect / Engineer of Record)
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
P GEORGOPOULOS ARCHITECT PC603/21/2026
NATIONAL MAINTENANCE403/21/2026
BUILDING BROTHERS803/21/2026
PEROTTO CONSULTING MANAGEMENT803/21/2026
PAUL FUSCO CONSULTING203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
MILLENIUM CENT CONTR CORPGeneral Contractor1807/08/2026
GO GREEN CONSTRUCTION.INCGeneral Contractor707/08/2026
C & L MANAGEMENT USA CORPGeneral Contractor304/09/2026
SIGNSTAR NYCScaffold307/08/2026
HOWARD ZAMKOFFElectrical303/21/2026
NATIONAL MAINTENANCEScaffold207/08/2026
NEPTUNE SIGNS AWNINGSScaffold207/08/2026
OASIS PLOMO CORPGeneral Contractor207/08/2026
AVON PLBG & HTG INCFire Protection107/08/2026
AMERICAN RIGGING CORPElectrical103/21/2026
METROPOLITAN MECHANICAL CGeneral Contractor107/08/2026
AMM GEN'L CONTRACTING INCPlumbing107/08/2026
I DO PLUMBING & HTG INCPlumbing106/28/2026
A1 SPECIALIZED, INCScaffold107/08/2026
ACTIVE SIGNSScaffold107/08/2026
DARBY CONSTRUCTION SVC LLGeneral Contractor107/22/2026
FOY, REMERElectrical103/21/2026
FRANK LA GREGAElectrical103/21/2026
HEMNATH, BHOOWANESHWARNAUTHElectrical103/21/2026
H&F IRON WORKSElectrical103/21/2026
HICKEY, DAVIDElectrical103/21/2026
LEBO ELECTRIC LLCElectrical103/22/2026
AMM GEN'L CONTRACTING.INCFire Protection107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
SCO ENGINEERING PLLC9678812/08/2025
P GEORGOPOULOS ARCHITECT889403/09/2021
METROPOLITAN MECHANICAL C2277110/12/2020
RELIANCE ENGINEERING, P.C322210/30/2019
Building Lifecycle
All (221)Filed (32)Permit Issued (31)Signed Off (16)Violation (60)Inspection (16)Objection (36)Special Inspection (30)
07/21/2026
Permit issued — General Construction
B01418210-I1-GC
07/16/2026
Filed — Alteration
Demolition of interior non-bearing partitions and finishes in existing commercial space. No change in use, egress, or occupancy.
B01418210-I1
06/17/2026
Special inspection requirement — Final
Scott Spector
04/27/2026
Signed off — Alteration
INSTALLATION OF AN ILLUMINATED BUSINESS ACCESSORY SIGN . NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B01303511-I1
04/01/2026
Inspection — Pass-Final Sign Permit Inspection
Pass
View inspection ↗
03/04/2026
Inspection — Pass-Final Sign Permit Inspection
Pass
View inspection ↗
02/03/2026
Permit issued — Sign
B01303511-I1-SG
02/03/2026
Permit issued — Sign
B01303505-I1-SG
12/11/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Seungchul Ok
12/08/2025
Filed — Alteration
MINOR INTERIOR RENOVATION OF EXISTING MERCANTILE STORE TO HAVE A NEW SUPERMARKET INCLUDING NEW PLUMBING FIXTURES. SPRINKLER WILL BE FILED UNDER SEPARATE APPLICATION. NO CHANGE USE EGRESS OR OCCUPANCY
B01204982-P5
11/21/2025
Inspection — Fail-Final PL - Up to 3 Requested Floors
Fail
View inspection ↗
11/20/2025
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
11/18/2025
Permit issued — Mechanical Systems
B01204982-S2-MS
11/14/2025
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
11/13/2025
Inspection — Certified Sprinkler-SP-Fixtures-Finish
Certified
View inspection ↗
11/10/2025
Signed off — Alteration
INSTALLATION OF TEMPORARY WOOD FENCE ONLY
B01204985-I1
11/10/2025
Signed off — Alteration
INSTALLATION OF TEMPORARY WOOD FENCE ONLY
B01204985-S1
11/10/2025
Signed off — Alteration
MINOR INTERIOR RENOVATION OF EXISTING MERCANTILE STORE TO HAVE A NEW SUPERMARKET INCLUDING NEW PLUMBING FIXTURES. SPRINKLER WILL BE FILED UNDER SEPARATE APPLICATION. NO CHANGE USE EGRESS OR OCCUPANCY
B01204982-S5
11/07/2025
Special inspection requirement — Sprinkler Systems
Seungchul Ok
11/05/2025
Inspection — Fail-Final General Construction Non-Directive 14
Fail
View inspection ↗
11/05/2025
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
11/01/2025
Filed — Alteration
INSTALLATION OF AN ILLUMINATED BUSINESS ACCESSORY SIGN . NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B01303511-I1
11/01/2025
Filed — Alteration
INSTALLATION OF AN ILLUMINATED BUSINESS ACCESSORY SIGN . NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B01303505-I1
11/01/2025
Filed — Alteration
MINOR INTERIOR RENOVATION OF EXISTING MERCANTILE STORE TO HAVE A NEW SUPERMARKET INCLUDING NEW PLUMBING FIXTURES. SPRINKLER WILL BE FILED UNDER SEPARATE APPLICATION. NO CHANGE USE EGRESS OR OCCUPANCY
B01204982-P4
11/01/2025
Filed — Alteration
MINOR INTERIOR RENOVATION OF EXISTING MERCANTILE STORE TO HAVE A NEW SUPERMARKET INCLUDING NEW PLUMBING FIXTURES. SPRINKLER WILL BE FILED UNDER SEPARATE APPLICATION. NO CHANGE USE EGRESS OR OCCUPANCY
B01204982-S2
10/29/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Seungchul Ok
10/29/2025
Special inspection requirement — Fire-Resistance Rated Construction
10/29/2025
Special inspection requirement — Interior lighting power
Seungchul Ok
10/29/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
10/27/2025
Filed — Alteration
MINOR INTERIOR RENOVATION OF EXISTING MERCANTILE STORE TO HAVE A NEW SUPERMARKET INCLUDING NEW PLUMBING FIXTURES. SPRINKLER WILL BE FILED UNDER SEPARATE APPLICATION. NO CHANGE USE EGRESS OR OCCUPANCY
B01204982-P3
10/15/2025
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
10/02/2025
Objection raised — Cost
10/02/2025
Objection resolved — Addressed
09/30/2025
Filed — Alteration
MINOR INTERIOR RENOVATION OF EXISTING MERCANTILE STORE TO HAVE A NEW SUPERMARKET INCLUDING NEW PLUMBING FIXTURES. SPRINKLER WILL BE FILED UNDER SEPARATE APPLICATION. NO CHANGE USE EGRESS OR OCCUPANCY
B01204982-P2
09/12/2025
Inspection — Certified StandPipe-Fire Pump (SD)-Fire Pump Test
Certified
View inspection ↗
08/19/2025
Permit issued — Sprinklers
B01204982-S1-EW-SP
08/04/2025
Objection resolved — Addressed
08/04/2025
Objection resolved — Addressed
08/01/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
07/29/2025
Inspection — Certified StandPipe-SD-Piping-Hydrostatic Test
Certified
View inspection ↗
07/17/2025
Permit issued — General Construction
B01204982-I1-GC
07/16/2025
Permit issued — Construction Fence
B01204982-S5-FN
07/01/2025
Filed — Alteration
MINOR INTERIOR RENOVATION OF EXISTING MERCANTILE STORE TO HAVE A NEW SUPERMARKET INCLUDING NEW PLUMBING FIXTURES. SPRINKLER WILL BE FILED UNDER SEPARATE APPLICATION. NO CHANGE USE EGRESS OR OCCUPANCY
B01204982-S5
07/01/2025
Filed — Alteration
MINOR INTERIOR RENOVATION OF EXISTING MERCANTILE STORE TO HAVE A NEW SUPERMARKET INCLUDING NEW PLUMBING FIXTURES. SPRINKLER WILL BE FILED UNDER SEPARATE APPLICATION. NO CHANGE USE EGRESS OR OCCUPANCY
B01204982-P1
06/30/2025
Special inspection requirement — Interior lighting power
06/30/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
06/25/2025
Permit issued — Plumbing
B01204982-S3-PL
05/29/2025
Filed — Alteration
MINOR INTERIOR RENOVATION OF EXISTING MERCANTILE STORE TO HAVE A NEW SUPERMARKET INCLUDING NEW PLUMBING FIXTURES. SPRINKLER WILL BE FILED UNDER SEPARATE APPLICATION. NO CHANGE USE EGRESS OR OCCUPANCY
B01204982-S3
05/23/2025
Objection raised — Fire_Protection
05/21/2025
Objection resolved — Addressed
05/21/2025
Objection resolved — Addressed
05/21/2025
Objection resolved — Addressed
05/21/2025
Objection resolved — Addressed
05/14/2025
Objection raised — Cost
05/14/2025
Special inspection requirement — Final
Seungchul Ok
05/14/2025
Special inspection requirement — Mechanical Systems
Seungchul Ok
05/13/2025
Filed — Alteration
MINOR INTERIOR RENOVATION OF EXISTING MERCANTILE STORE TO HAVE A NEW SUPERMARKET INCLUDING NEW PLUMBING FIXTURES. SPRINKLER WILL BE FILED UNDER SEPARATE APPLICATION. NO CHANGE USE EGRESS OR OCCUPANCY
B01204982-S1
05/13/2025
Objection raised — Fire_Protection
05/13/2025
Objection raised — Fire_Protection
05/13/2025
Objection raised — Fire_Protection
Latest 60 of 221 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionPermit IssuedDARBY CONSTRUCTION SVC LL07/21/2026
DOB NOWSignSigned-offNEPTUNE SIGNS&AWNINGS INC02/03/2026
DOB NOWSignSigned-offNEPTUNE SIGNS&AWNINGS INC02/03/2026
DOB NOWMechanical SystemsPermit IssuedC & L MANAGEMENT USA CORP11/18/2025
DOB NOWSprinklersPermit IssuedAVON PLBG & HTG INC08/19/2025
DOB NOWGeneral ConstructionSigned-offC & L MANAGEMENT USA CORP07/17/2025
DOB NOWConstruction FenceSigned-offC & L MANAGEMENT USA CORP07/16/2025
DOB NOWPlumbingPermit IssuedI DO PLUMBING & HTG INC06/25/2025
DOB NOWGeneral ConstructionSigned-offOASIS PLOMO CORP04/16/2025
DOB NOWConstruction FenceSigned-offOASIS PLOMO CORP04/14/2025
DOB NOWSignSigned-offSIGNSTAR NYC01/28/2025
DOB NOWSignSigned-offSIGNSTAR NYC01/28/2025
DOB NOWSignSigned-offMAD SIGNS INC07/26/2023
DOB NOWSignSigned-offNATIONAL MAINTENANCE, INC08/16/2021
DOB NOWStructuralPermit IssuedMILLENIUM CENT CONTR CORP05/17/2021
DOB NOWGeneral ConstructionSigned-offMILLENIUM CENT CONTR CORP05/17/2021
DOB NOWConstruction FenceSigned-offMILLENIUM CENT CONTR CORP05/17/2021
DOB NOWMechanical SystemsSigned-offMILLENIUM CENT CONTR CORP05/17/2021
DOB NOWStructuralPermit IssuedMILLENIUM CENT CONTR CORP04/29/2021
DOB NOWSignSigned-offNATIONAL MAINTENANCE, INC04/26/2021
DOB NOWPlumbingSigned-offAMM GEN'L CONTRACTING.INC04/23/2021
DOB NOWPlumbingSigned-offAMM GEN'L CONTRACTING INC04/23/2021
DOB NOWMechanical SystemsSigned-offMILLENIUM CENT CONTR CORP03/23/2021
DOB NOWGeneral ConstructionSigned-offMILLENIUM CENT CONTR CORP03/10/2021
DOB NOWConstruction FenceSigned-offMILLENIUM CENT CONTR CORP03/09/2021
DOB NOWMechanical SystemsSigned-offMETROPOLITAN MECHANICAL C10/16/2020
DOB NOWSignPermit IssuedACTIVE SIGNS INC01/31/2020
DOB NOWMechanical SystemsSigned-offGO GREEN CONSTRUCTION.INC12/24/2019
DOB NOWConstruction FenceSigned-offGO GREEN CONSTRUCTION.INC12/09/2019
DOB NOWStructuralSigned-offGO GREEN CONSTRUCTION.INC12/09/2019
DOB NOWSignSigned-offSIGNSTAR NYC02/11/2019
BISOTISSUEDM. FRIED STORE FIXTURES,12/18/2019
BISOTISSUEDGO GREEN CONSTRUCTION.INC11/01/2019
BISOTISSUEDGO GREEN CONSTRUCTION.INC11/01/2019
BISMHISSUEDSHEFF AIR CONDITIONING.IN02/18/2009
BISOTISSUEDA INJTERNATIONAL LTD10/13/2005
BIS—ISSUEDULTIMATE SIGNS&DESIGNS CO04/15/2003
BIS—ISSUEDBERGER SIGN FABRICATION INC10/29/2002
BISOTISSUEDWOODROW CONSTRUCTION INC08/21/2002
BISEQISSUEDWOODROW CONSTRUCTION INC08/21/2002
+ 34 more permits on file
2 projects · most recent 12/08/2025
Refrigeration Systems Ventilation Systems Air Conditioning Systems Heating Systems
FiledStatusContractorScopeMake / Model / Capacity
12/08/2025Permit IssuedC & L MANAGEMENT USA CORPRefrigeration Systems, Ventilation Systems
Ventilation
Dayton Model#: 56JN92 3,996 CFM · Kitchen Exhaust ×1
Refrigeration
Bohn BRH 086 67,000 CFM · Condensing Unit ×1
BRH 132 84,800 CFM · Condensing Unit ×1
03/09/2021Signed-offMILLENIUM CENT CONTR CORPAir Conditioning Systems, Heating Systems
Cooling
Mitsubishi Electric (2) Modules PURY-P96YNU-A 192,000 BTU · Vrf Outdoor ×1
PUY-A18NKA7 18,000 BTU · Heat Pump Outdoor ×1
Heating
Mitsubishi Electric (2) Modules PURY-P96YNU-A 192,000 BTU · Vrf Outdoor ×1
2 projects · most recent 12/08/2025
FiledStatusContractorScope
12/08/2025Permit IssuedAVON PLBG & HTG INC142 heads
03/09/2021Signed-offAMM GEN'L CONTRACTING.INC48 heads
2 projects · most recent 12/08/2025
Water/Sanitary Gas
FiledStatusContractorScope
12/08/2025Permit IssuedI DO PLUMBING & HTG INCGas, Water/Sanitary
03/09/2021Signed-offAMM GEN'L CONTRACTING INCWater/Sanitary
10 projects · most recent 07/09/2026
General Wiring
FiledStatusContractorScope
07/09/2026CompleteVOLTRON ELECTRIC LLC—
05/01/2026CompleteTRINITY METRO ELECL CORPGeneral Wiring
10/01/2025CompleteJONG HYUN KIM—
06/16/2025CompleteCHAMPION ELECTRIC INCGeneral Wiring
05/19/2025CompleteCHAMPION ELECTRIC INC1 meters, 1 new_meters
12/10/2024CompleteRAINBOW ELECTRIC CO., INC—
06/03/2023Permit IssuedA ELECTRICAL MAIN SVC INC—
03/01/2020CompleteLEBO ELECTRIC LLCGeneral Wiring
01/14/2020CompleteRAINBOW ELECTRIC CO., INC—
02/11/2019Permit IssuedROBERT S. COVELLO—
1 project · most recent 02/17/2021
Steel Wood
FiledStatusContractorScope
02/17/2021Permit IssuedMILLENIUM CENT CONTR CORPSteel, Wood
1 project · most recent 12/08/2025
Fence
FiledStatusContractorScope
12/08/2025Permit IssuedC & L MANAGEMENT USA CORPFence
1 project · most recent 12/08/2025
Construction Fence
FiledStatusContractorScope
12/08/2025Permit IssuedC & L MANAGEMENT USA CORPConstruction Fence
▾Field Inspections (DOB CAP) — 16
DateTypeResultReport
04/01/2026Pass-Final Sign Permit InspectionPassView ↗
03/04/2026Pass-Final Sign Permit InspectionPassView ↗
11/21/2025Fail-Final PL - Up to 3 Requested FloorsFailView ↗
11/20/2025Pass-Final General Construction Non-Directive 14PassView ↗
11/14/2025Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
11/13/2025Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
11/05/2025Fail-Final General Construction Non-Directive 14FailView ↗
11/05/2025Pass-Final General Construction Non-Directive 14PassView ↗
10/15/2025Pass-Final PL - Up to 3 Requested FloorsPassView ↗
09/12/2025Certified StandPipe-Fire Pump (SD)-Fire Pump TestCertifiedView ↗
08/01/2025Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
07/29/2025Certified StandPipe-SD-Piping-Hydrostatic TestCertifiedView ↗
09/12/2023Pass-Final PL - Up to 3 Requested FloorsPassView ↗
09/06/2023Pass-Final PL - Up to 3 Requested FloorsPassView ↗
08/30/2023Pass-Final PL - Up to 3 Requested FloorsPassView ↗
08/25/2023Pass-Final PL - Up to 3 Requested FloorsPassView ↗
▾Special Inspection Requirements (DOB NOW) — 33
DateRequirementInspectorRole
06/17/2026FinalScott Spectorprogress
12/11/2025Fire-Resistant Penetrations and JointsSeungchul Okspecial
11/07/2025Sprinkler SystemsSeungchul Okspecial
10/29/2025Fire-Resistant Penetrations and JointsSeungchul Okspecial
10/29/2025Fire-Resistance Rated Construction—progress
10/29/2025Interior lighting powerSeungchul Okenergy_progress
10/29/2025Structural Stability – Alterations of existing buildings—special
06/30/2025Interior lighting power—energy_progress
06/30/2025Fire-Resistant Penetrations and Joints—special
05/14/2025FinalSeungchul Okprogress
05/14/2025Mechanical SystemsSeungchul Okspecial
10/08/2024FinalLEON SKVIRSKYprogress
04/15/2021FinalAHMED SHAABANprogress
03/08/2021FinalAHMED SHAABANprogress
02/24/2021Duct leakage testing, insulation and designVasilios Georgopoulosenergy_progress
02/24/2021Energy Code ComplianceVasilios Georgopoulosprogress
02/24/2021HVAC-R and service water piping design and insulationVasilios Georgopoulosenergy_progress
02/24/2021HVAC-R and service water heating system controlsVasilios Georgopoulosenergy_progress
02/24/2021HVAC-R and service water heating equipmentVasilios Georgopoulosenergy_progress
02/23/2021FinalVasilios Georgopoulosprogress
02/23/2021Mechanical SystemsVasilios Georgopoulosspecial
02/07/2021Structural Stability – Alterations of existing buildingsVasilios Georgopoulosspecial
02/07/2021Structural Steel - High Strength BoltingVasilios Georgopoulosspecial
02/07/2021Structural Steel - DetailsVasilios Georgopoulosspecial
02/07/2021Structural Steel - WeldingVasilios Georgopoulosspecial
Latest 25 of 33.
▾Tenants in the building
TenantSpaceFloorsRenovation projects
Municipal Credit UnionOfficeFloor 1
Project B01418210 Alteration · Permit Entire · 07/16/2026
Humana BrookylynMedical / HealthcareCellar, Floor 1
Project B00475237 Alteration · Permit Entire · 03/09/2021
Read from each project’s drawing title blocks and cover sheets and checked twice; a name appears only when it is the occupant, never the owner, landlord or designer.
▾Documents — 212 on file (BIS + DOB NOW)
▸Plans & Drawings33
▸DOB NOWPlans/Sketch22
09/01/2026B00480256-I1Request digital key ↗
09/01/2026B00480257-I1Request digital key ↗
09/01/2026B00480729-I1Request digital key ↗
Showing 3 of 22 on file for this type
▸DOB NOWPlans/Sketch - Mechanical Systems3
09/02/2026B00233625-I1Request digital key ↗
09/02/2026B00405098-I1Request digital key ↗
09/01/2026B00475245-I1Request digital key ↗
▸DOB NOWPlans/Sketch - Structural3
09/02/2026B00240199-I1Request digital key ↗
08/15/2026B00240199-P1Request digital key ↗
08/15/2026B00466581-I1Request digital key ↗
▸DOB NOWPlans/Sketch - Sign2
09/02/2026B00121207-I1Request digital key ↗
09/02/2026B00258303-I1Request digital key ↗
▸DOB NOWPlans/Sketch - Construction Fence1
09/02/2026B00229393-I1Request digital key ↗
▸DOB NOWPlans/Sketch - Plumbing1
08/15/2026B00475237-I1Request digital key ↗
▸DOB NOWPlans/Sketch - Sprinkler1
08/15/2026B00475237-I1Request digital key ↗
▸Applications & Permits20
▸BISPLAN / WORK APPROVAL APPLICATION15
05/15/2024320774523Open ↗
03/12/2024340695705Open ↗
03/11/2024340695705Open ↗
Showing 3 of 15 on file for this type
▸BISWORK PERMIT APPLICATION5
12/18/2019340695705Open ↗
11/01/2019321827038Open ↗
11/01/2019321827038Open ↗
Showing 3 of 5 on file for this type
▸Seals & Professional Certifications69
▸DOB NOWDPL-1: Design Professional Seal & Signature32
09/02/2026B00121207-I1Open ↗
09/02/2026B00405098-I1Open ↗
09/01/2026B00466581-I1Open ↗
Showing 3 of 32 on file for this type
▸DOB NOWProgress Inspector Seal & Signature13
09/30/2026B00480729-I1Open ↗
09/23/2026B01204982-S2Open ↗
09/20/2026B00480729-S1Open ↗
Showing 3 of 13 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION7
11/01/2019321827038Open ↗
11/01/2019321827038Open ↗
10/17/2019321827038Open ↗
Showing 3 of 7 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature7
09/23/2026B01204982-S1Open ↗
09/23/2026B01204982-S2Open ↗
08/29/2026B01204982-I1Open ↗
Showing 3 of 7 on file for this type
▸BISPROFESSIONAL CERTIFIED CHECKLIST3
10/17/2019321827038Open ↗
12/23/2008310237838Open ↗
10/28/2008310219466Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT2
10/17/2019321827038Open ↗
10/17/2019321827038Open ↗
▸BISAPPLICANT OWNER SIGNATURE2
12/08/2020340792244Open ↗
09/11/2019340695705Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM2
12/23/2008310237838Open ↗
10/28/2008310219466Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
12/08/2020340792244Open ↗
▸Trade Schedules & Equipment3
▸BISEQUIPMENT USE APPLICATION/PERMIT2
12/23/2008310237838Open ↗
11/05/2008310219466Open ↗
▸BISSCHEDULE B - PLUMBING1
12/23/2008310237838Open ↗
▸Safety & Tenant Protection1
▸BISSTREET TREE CHECKLIST1
10/17/2019321827038Open ↗
▸Environmental & Asbestos47
▸DOB NOWDEP ACP-5: Asbestos Assessment Report25
09/02/2026B00121207-I1Open ↗
09/02/2026B00405098-I1Open ↗
09/01/2026B00480257-I1Open ↗
Showing 3 of 25 on file for this type
▸DOB NOWOER: Notice to Proceed12
09/01/2026B00475245-I1Open ↗
08/15/2026B00475237-I1Open ↗
08/13/2026B00258303-I1Open ↗
Showing 3 of 12 on file for this type
▸DOB NOWOER: Notice of Satisfaction4
08/13/2026B00229393-I1Open ↗
08/13/2026B01204982-S1Open ↗
08/13/2026B01204985-I1Open ↗
Showing 3 of 4 on file for this type
▸BISENVIRONMENTAL RESTRICTIONS - OER NOTICE OF SATISFACTION2
04/01/2024340695705Open ↗
04/06/2021321827038Open ↗
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
10/17/2019321827038Open ↗
▸BISENVIRONMENTAL RESTRICTIONS - OER NOTICE TO PROCEED1
12/10/2019340695705Open ↗
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'1
12/23/2008310237838Open ↗
▸BISASBESTOS EXEMPTION CERTIFICATION LETTER1
10/28/2008310219466Open ↗
▸Energy Compliance11
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS3
11/01/2019321827038Open ↗
10/17/2019321827038Open ↗
10/17/2019321827038Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY3
04/13/2021321827038Open ↗
04/13/2021321827038Open ↗
12/04/2019340695705Open ↗
▸BISAS-BUILT ENERGY ANALYSIS (EN2)2
04/17/2024340695705Open ↗
04/06/2021321827038Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY FOR ENERGY CODE PROGRESS INSPECTIONS1
12/08/2020340792244Open ↗
▸BISAIR SEALING AND INSULATION - VISUAL1
04/13/2021321827038Open ↗
▸DOB NOWEN2: As Built Energy Analysis.1
08/13/2026B00480257-I1Open ↗
▸Inspections & Test Reports3
▸BISTECHNICAL REPORT: RESPONSIBILITY2
04/13/2021321827038Open ↗
04/13/2021321827038Open ↗
▸BISFIRE-RESISTIVE RATED CONSTRUCTION1
04/13/2021321827038Open ↗
▸Approvals, Objections & Sign-offs6
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST3
04/18/2024340695705Open ↗
04/13/2021321827038Open ↗
11/03/2008310219466Open ↗
▸BISADMINISTRATIVE OBJECTIONS2
12/23/2008310237838Open ↗
10/28/2008310219466Open ↗
▸BISFINAL1
04/06/2021321827038Open ↗
▸Cost, Insurance & Ownership7
▸BISCOST AFFIDAVIT5
12/04/2019340695705Open ↗
10/17/2019321827038Open ↗
10/17/2019321827038Open ↗
Showing 3 of 5 on file for this type
▸BISCOST AFFIDAVIT (FINAL): PW32
04/17/2024340695705Open ↗
04/06/2021321827038Open ↗
▸Filing & Intake Forms10
▸BISEFILING COVER SHEET5
10/21/2019321827038Open ↗
10/21/2019321827038Open ↗
06/29/2013320774523Open ↗
Showing 3 of 5 on file for this type
▸BISADDITIONAL INFORMATION3
01/15/2020340695705Open ↗
12/04/2019340695705Open ↗
11/20/2019340695705Open ↗
▸BISEFILING JOB APPLICATION COVER SHEET2
12/08/2020340792244Open ↗
09/11/2019340695705Open ↗
▸Other Documents2
▸BISEXTERNAL FORMS - SUPPORTING DOCUMENTATION2
04/18/2024340695705Open ↗
11/09/2019321827038Open ↗