← Back
BuildNYC
Two family brick
1558 REMSEN AVENUE
BROOKLYN · Canarsie · BIN 3227616
💬 Discuss this project
1960Year Built
2Stories
B1Building Class
R4Zoning
2,580 sfGross Floor Area
2Units
0 Active ViolationsFDNY Report ↗
Two family brick · 2,450 sf lot · 1.05 FAR built · Flood zone X500
Locations of Work
Plumbing
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
Cellar7p · 2 filings · 20 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
Azsk Architects701/31/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
S S Architectural Design203/21/2026
MMSR Consulting Group1203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
Dynamic Plumbing & SprinklerPlumbing207/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
M. International Engineering3129501/31/2024
Buildtech Engineering6369108/03/2021
Building Lifecycle
07/05/2024
Closed: Class "a" apt. Created at cellar with full kitchen, 3 pcs bathroom , 2 rooms for sleeping and living room
DOB violation · closed on the city's record
07/05/2024
Closed: Water and waste line installed for residential sink, also installed unpermitted gas line for stove
DOB violation · closed on the city's record
06/17/2024
Rca was issued on 7/29/2022 by inspector badge # 2956 . Inspector observed residence converted from a legal 2 family to 3 family by creating class…
ECB violation · closed
04/09/2024
Signed off — Alteration
Herewith file application to cap and remove gas hook up installation of gas dryer on existing gas line
B08011296-I1
03/15/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
NANIK MASSAND
47 history events on file for this building. Sign in free to see the full history. Sign in · Create account
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offCitywide Plumbing & Heating & SPKLS04/03/2023
DOB NOWPlumbingSigned-offCitywide Plumbing & Heating & SPKLS09/03/2021
BISOTISSUEDMonte Simon07/21/2017
Nothing on file for this building.
▾Field Inspections (DOB CAP) — 6
DateTypeResultReport
08/23/2023Pass-Final PL - Up to 3 Requested FloorsPassView ↗
07/22/2023Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
07/21/2023Pass-Final PL - Up to 3 Requested FloorsPassView ↗
06/08/2023Certified Gas-Gas-Piping-RoughingCertifiedView ↗
06/06/2023Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
10/18/2021Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 7
DateRequirementInspectorRole
03/15/2024Fire-Resistant Penetrations and JointsNANIK MASSANDspecial
01/05/2024Fire-Resistant Penetrations and JointsNANIK MASSANDspecial
08/02/2023Fire-Resistant Penetrations and JointsNANIK MASSANDspecial
06/23/2023Fire-Resistant Penetrations and JointsNANIK MASSANDspecial
03/07/2023Fire-Resistant Penetrations and JointsNANIK MASSANDspecial
02/14/2023Fire-Resistant Penetrations and Joints—special
07/28/2021Fire-Resistant Penetrations and JointsLuis Pichardospecial
35 filed documents on file for this building. Sign in free to see the full history. Sign in · Create account