← Back
Two family brick
156-44 102 STREET
QUEENS · Howard Beach-Lindenwood · BIN 4295025
💬 Discuss this project
1940Year Built
2Stories
B1Building Class
R3XZoning
2,496 sfGross Floor Area
2Units
Two family brick · 4,000 sf lot · 0.62 FAR built · Flood zone X500
Locations of Work
Architecture
Roof3p · 1 filing · 7 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
07/28/2023$925K—— → —$371/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
NY BUILDING ASSOCIATES INC103/27/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
S R SOLAR DESIGN203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
LONG ISLAND POWER SOLUTIOGeneral Contractor203/21/2026
CATIZONE ELECTRICAL INCElectrical103/22/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
NKM ENGINEERING PLLC6244103/27/2025
Building Lifecycle
All (8)Filed (1)Permit Issued (1)Signed Off (1)Special Inspection (5)
06/05/2025
Signed off — Alteration
INSTALLATION OF SOLAR PANELS ON EXISTING ROOF. NO CHANGE IN USE, OCCUPANCY, OR EGRESS. NO CHANGE IN BULK
Q01194562-I1
04/07/2025
Permit issued — Solar
Q01194562-I1-SL
03/27/2025
Filed — Alteration
INSTALLATION OF SOLAR PANELS ON EXISTING ROOF. NO CHANGE IN USE, OCCUPANCY, OR EGRESS. NO CHANGE IN BULK
Q01194562-I1
03/13/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
NARESH MAHANGU
03/13/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
NARESH MAHANGU
03/13/2025
Special inspection requirement — Energy Code Compliance Inspections
NARESH MAHANGU
03/13/2025
Special inspection requirement — Final
NARESH MAHANGU
03/13/2025
Special inspection requirement — Air barrier - visual inspection
NARESH MAHANGU
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarSigned-offLONG ISLAND POWER SOLUTIO04/07/2025
1 project · most recent 03/13/2025
FiledStatusContractorScope
03/13/2025CompleteCATIZONE ELECTRICAL INC—
▾Special Inspection Requirements (DOB NOW) — 5
DateRequirementInspectorRole
03/13/2025Fire-Resistant Penetrations and JointsNARESH MAHANGUspecial
03/13/2025Structural Stability – Alterations of existing buildingsNARESH MAHANGUspecial
03/13/2025Energy Code Compliance InspectionsNARESH MAHANGUprogress
03/13/2025FinalNARESH MAHANGUprogress
03/13/2025Air barrier - visual inspectionNARESH MAHANGUenergy_progress
▾Documents — 13 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/20/2026Q01194562-I1Request digital key ↗
▸Applications & Permits1
▸BISPLAN / WORK APPROVAL APPLICATION1
08/31/2016421366667Open ↗
▸Seals & Professional Certifications5
▸DOB NOWProgress Inspector Seal & Signature2
08/26/2026Q01194562-I1Open ↗
08/26/2026Q01194562-I1Open ↗
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION1
08/31/2016421366667Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/20/2026Q01194562-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/26/2026Q01194562-I1Open ↗
▸Trade Schedules & Equipment1
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE1
08/31/2016421366667Open ↗
▸Environmental & Asbestos1
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/20/2026Q01194562-I1Open ↗
▸Approvals, Objections & Sign-offs2
▸BISADMINISTRATIVE OBJECTIONS1
08/31/2016421366667Open ↗
▸DOB NOWUtility Company Final Acceptance Letter1
08/13/2026Q01194562-I1Open ↗
▸Cost, Insurance & Ownership1
▸BISCOST AFFIDAVIT1
08/31/2016421366667Open ↗
▸Filing & Intake Forms1
▸BISEFILING COVER SHEET1
08/31/2016421366667Open ↗