← Back
Multi-story retail building (2+)
156 NAGLE AVENUE
MANHATTAN · BIN 1084401
💬 Discuss this project
1913Year Built
2Stories
K2Building Class
C4-4Zoning
14,203 sfGross Floor Area
13Units
2 Open Violations 1 unresolved · 1 paperwork only ▸
Multi-story retail building (2+) · Owner of record: CYCKMAN CRESTVIEW REALTY, · 10,000 sf lot · 1.42 FAR built · Flood zone X
Locations of Work
MechanicalPlumbing
Roof4p · 1 filing · 20 docs
Floor 18p · 1 filing · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
CYCKMAN CRESTVIEW REALTY,2603/22/2026
CASTRO203/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
URBAN ARCHITECTURAL DESIGN, PC503/05/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
YBL NY603/21/2026
SUN203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
WE R DECOR CORPGeneral Contractor603/21/2026
PETER PANTELICElectrical203/21/2026
ALL PRO PLBG & HTG INCPlumbing207/08/2026
CAPE PLUMBING INCPlumbing106/28/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
A&B WORLD CONSULTING, INC5704503/05/2025
Building Lifecycle
All (79)Filed (5)Permit Issued (5)Violation (54)Inspection (2)Special Inspection (13)
05/07/2025
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
03/21/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
03/07/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Alexander Bomstein
03/06/2025
Permit issued — Plumbing
M00929228-S1-PL
03/05/2025
Filed — Alteration
JOB FILED TO FIT-OUT EXIST RETAIL STORE INCLUDING NEW COUNTER AND EQUIPMENT, INSTALL COMMERCIAL KITCHEN HOOD AND FIRE SUPPRESSION SYSTEM AS PER PLAN. NO CHANGE OF USE, EGRESS, OR OCCUPANCY UNDER THIS APPLICATION.
M00929228-P3
03/05/2025
Filed — Alteration
JOB FILED TO FIT-OUT EXIST RETAIL STORE INCLUDING NEW COUNTER AND EQUIPMENT, INSTALL COMMERCIAL KITCHEN HOOD AND FIRE SUPPRESSION SYSTEM AS PER PLAN. NO CHANGE OF USE, EGRESS, OR OCCUPANCY UNDER THIS APPLICATION.
M00929228-P2
03/04/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Alexander Bomstein
01/06/2025
Permit issued — Plumbing
M00929228-S1-PL
01/25/2024
Permit issued — Mechanical Systems
M00929228-I1-GC-CX
01/22/2024
Special inspection requirement — Mechanical Systems
Alexander Bomstein
01/22/2024
Special inspection requirement — Energy Code Compliance Inspections
Alexander Bomstein
01/22/2024
Special inspection requirement — Final
Alexander Bomstein
01/22/2024
Special inspection requirement — Interior lighting power
Alexander Bomstein
01/22/2024
Special inspection requirement — HVAC-R and service water piping design and insulation
Alexander Bomstein
01/22/2024
Special inspection requirement — HVAC-R and service water heating system controls
Alexander Bomstein
01/22/2024
Special inspection requirement — HVAC-R and service water heating equipment
Alexander Bomstein
01/22/2024
Special inspection requirement — Shutoff dampers
Alexander Bomstein
01/22/2024
Special inspection requirement — Maintenance information
Alexander Bomstein
01/22/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
Alexander Bomstein
01/19/2024
Filed — Alteration
JOB FILED TO FIT-OUT EXIST RETAIL STORE INCLUDING NEW COUNTER AND EQUIPMENT, INSTALL COMMERCIAL KITCHEN HOOD AND FIRE SUPPRESSION SYSTEM AS PER PLAN. NO CHANGE OF USE, EGRESS, OR OCCUPANCY UNDER THIS APPLICATION.
M00929228-P1
01/16/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
Alexander Bomstein
10/05/2023
Permit issued — Plumbing
M00929228-S1-PL
09/21/2023
Permit issued — Mechanical Systems
M00929228-I1-GC-CX
09/15/2023
Filed — Alteration
JOB FILED TO FIT-OUT EXIST RETAIL STORE INCLUDING NEW COUNTER AND EQUIPMENT, INSTALL COMMERCIAL KITCHEN HOOD AND FIRE SUPPRESSION SYSTEM AS PER PLAN. NO CHANGE OF USE, EGRESS, OR OCCUPANCY UNDER THIS APPLICATION.
M00929228-S1
09/15/2023
Filed — Alteration
JOB FILED TO FIT-OUT EXIST RETAIL STORE INCLUDING NEW COUNTER AND EQUIPMENT, INSTALL COMMERCIAL KITCHEN HOOD AND FIRE SUPPRESSION SYSTEM AS PER PLAN. NO CHANGE OF USE, EGRESS, OR OCCUPANCY UNDER THIS APPLICATION.
M00929228-I1
01/27/2020
Violation issued (ECB, closed)
Construction
12/17/2019
Violation issued (ECB, closed)
Construction
12/12/2019
Violation issued (ECB, closed)
Construction
12/12/2019
Violation issued (ECB, closed)
Construction
11/04/2019
Violation issued (ECB, closed)
Construction
10/22/2019
Violation issued (ECB, closed)
Construction
09/07/2019
Violation issued (ECB, closed)
Construction
09/04/2019
Violation issued (ECB, closed)
Construction
06/29/2019
Violation issued (ECB, closed)
Construction
06/29/2019
Violation issued (ECB, closed)
Construction
05/29/2019
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
05/29/2019
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
05/29/2019
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
05/29/2019
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
05/29/2019
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
05/29/2019
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
05/29/2019
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
05/29/2019
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
05/29/2019
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
04/18/2019
Violation issued (ECB, closed)
Construction
04/13/2019
Violation issued (ECB, closed)
Construction
04/13/2019
Violation issued (ECB, closed)
Construction
03/09/2019
Violation issued (ECB, closed)
Construction
03/09/2019
Violation issued (ECB, closed)
Construction
03/09/2019
Violation issued (ECB, closed)
Construction
03/09/2019
Violation issued (ECB, closed)
Plumbing
03/09/2019
Violation issued (ECB, open)
Construction
03/08/2019
Violation issued (ECB, closed)
Construction
03/08/2019
Violation issued (ECB, closed)
Unknown
03/08/2019
Violation issued (ECB, closed)
Construction
03/08/2019
Violation issued (ECB, closed)
Construction
03/08/2019
Violation issued (ECB, closed)
Unknown
03/08/2019
Violation issued (ECB, closed)
Construction
03/08/2019
Violation issued (ECB, closed)
Construction
03/08/2019
Violation issued (ECB, closed)
Unknown
Latest 60 of 79 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedCAPE PLUMBING INC03/06/2025
DOB NOWPlumbingPermit IssuedALL PRO PLBG & HTG INC01/06/2025
DOB NOWMechanical SystemsPermit IssuedWE R DECOR CORP01/25/2024
DOB NOWPlumbingPermit IssuedALL PRO PLBG & HTG INC10/05/2023
DOB NOWMechanical SystemsPermit IssuedWE R DECOR CORP09/21/2023
BISPLISSUEDMYRTO PLUMBING & HVAC COR05/17/2019
BISOTISSUEDCOMPLEX DEVELOPMENT INC05/10/2019
BISOTISSUEDCARDINAL ONE BUILDING LLC11/18/2013
BISEQISSUEDCARDINAL ONE BUILDING LLC11/18/2013
BISFPISSUEDN.Y BUSINESS FIRE SYS INC01/14/2009
BISFPISSUEDJEM FIRE PREVENTION INC05/31/2007
BISPLISSUEDARIANA CONTRACTING INC03/16/2007
BISOTISSUEDCHASE CONTRACTORS03/14/2007
BISEQISSUEDCHASE CONTRACTORS03/14/2007
1 project · most recent 03/05/2025
Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
03/05/2025Permit IssuedWE R DECOR CORPVentilation Systems
Ventilation
Captiveaire EA1-D.250-16Z 6,800 CFM · Makeup Air ×4
Econ-Air EADU180H 6,800 CFM · Exhaust Fan ×4
1 project · most recent 03/05/2025
Gas Water/Sanitary
FiledStatusContractorScope
03/05/2025Permit IssuedCAPE PLUMBING INCGas, Water/Sanitary
4 projects · most recent 05/30/2024
General Wiring
FiledStatusContractorScope
05/30/2024Permit IssuedWCK ELECTRIC CORP.12 meters, 1 new_meters
09/27/2023Permit IssuedWCK ELECTRIC CORP.General Wiring
03/08/2021CompletePK ELECTRIC INCGeneral Wiring
09/12/2019CompleteRIVIERA ELECTRIC CORPGeneral Wiring
▾Field Inspections (DOB CAP) — 2
DateTypeResultReport
05/07/2025Pass-Final CND-Occupancy InspectionPassView ↗
03/21/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 13
DateRequirementInspectorRole
03/07/2025Fire-Resistant Penetrations and JointsAlexander Bomsteinspecial
03/04/2025Fire-Resistant Penetrations and JointsAlexander Bomsteinspecial
01/22/2024Mechanical SystemsAlexander Bomsteinspecial
01/22/2024Energy Code Compliance InspectionsAlexander Bomsteinprogress
01/22/2024FinalAlexander Bomsteinprogress
01/22/2024Interior lighting powerAlexander Bomsteinenergy_progress
01/22/2024HVAC-R and service water piping design and insulationAlexander Bomsteinenergy_progress
01/22/2024HVAC-R and service water heating system controlsAlexander Bomsteinenergy_progress
01/22/2024HVAC-R and service water heating equipmentAlexander Bomsteinenergy_progress
01/22/2024Shutoff dampersAlexander Bomsteinenergy_progress
01/22/2024Maintenance informationAlexander Bomsteinenergy_progress
01/22/2024Fire-Resistant Penetrations and JointsAlexander Bomsteinspecial
01/16/2024Fire-Resistant Penetrations and JointsAlexander Bomsteinspecial
▾Documents — 91 on file (BIS + DOB NOW)
▸Plans & Drawings5
▸DOB NOWPlans/Sketch5
08/24/2026M00929228-P2Request digital key ↗
08/24/2026M00929228-S1Request digital key ↗
08/24/2026M00929228-P3Request digital key ↗
Showing 3 of 5 on file for this type
▸Applications & Permits19
▸BISWORK PERMIT APPLICATION9
05/17/2019123807728Open ↗
05/10/2019123807728Open ↗
05/10/2019123807728Open ↗
Showing 3 of 9 on file for this type
▸BISPLAN / WORK APPROVAL APPLICATION9
09/19/2019123902777Open ↗
08/26/2019123807728Open ↗
08/07/2019123807728Open ↗
Showing 3 of 9 on file for this type
▸BISPLACE OF ASSEMBLY1
09/29/2017122878207Open ↗
▸Seals & Professional Certifications28
▸DOB NOWProgress Inspector Seal & Signature8
08/26/2026M00929228-P2Open ↗
08/26/2026M00929228-P2Open ↗
08/26/2026M00929228-P2Open ↗
Showing 3 of 8 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION5
09/19/2019123902777Open ↗
04/30/2019123807728Open ↗
09/29/2017122878207Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature5
08/13/2026M00929228-P2Open ↗
08/13/2026M00929228-S1Open ↗
08/13/2026M00929228-P3Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature5
08/26/2026M00929228-P2Open ↗
08/26/2026M00929228-P2Open ↗
08/25/2026M00929228-P3Open ↗
Showing 3 of 5 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT3
04/30/2019123807728Open ↗
05/08/2017123079792Open ↗
11/18/2013121791828Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST2
04/30/2019123807728Open ↗
05/08/2017123079792Open ↗
▸Trade Schedules & Equipment5
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE5
08/26/2019123807728Open ↗
08/07/2019123807728Open ↗
07/17/2019123807728Open ↗
Showing 3 of 5 on file for this type
▸Environmental & Asbestos9
▸DOB NOWDEP ACP-5: Asbestos Assessment Report5
08/13/2026M00929228-I1Open ↗
08/13/2026M00929228-P3Open ↗
08/13/2026M00929228-P2Open ↗
Showing 3 of 5 on file for this type
▸BISASBESTOS: CERTIFICATION (DEP ACP5)3
04/30/2019123807728Open ↗
05/08/2017123079792Open ↗
11/20/2013121791828Open ↗
▸BISASBESTOS EXEMPTION CERTIFICATION LETTER1
01/07/2009110429019Open ↗
▸Energy Compliance4
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS4
04/30/2019123807728Open ↗
09/28/2017122878190Open ↗
05/08/2017123079792Open ↗
Showing 3 of 4 on file for this type
▸Inspections & Test Reports1
▸BISTECHNICAL REPORT: PILE DRIVING1
09/28/2017122878190Open ↗
▸Approvals, Objections & Sign-offs1
▸BISADMINISTRATIVE OBJECTIONS1
01/07/2009110429019Open ↗
▸Cost, Insurance & Ownership6
▸BISCOST AFFIDAVIT6
09/19/2019123902777Open ↗
04/30/2019123807728Open ↗
09/28/2017122878190Open ↗
Showing 3 of 6 on file for this type
▸Filing & Intake Forms11
▸BISEFILING COVER SHEET6
09/19/2019123902777Open ↗
04/30/2019123807728Open ↗
09/28/2017122878190Open ↗
Showing 3 of 6 on file for this type
▸BISBOROUGH INTAKE FORM3
08/26/2019123807728Open ↗
08/01/2019123807728Open ↗
07/12/2019123807728Open ↗
▸BISeFiling Job Application Cover Sheet1
01/07/2009110429019Open ↗
▸BISADDITIONAL INFORMATION1
07/17/2019123807728Open ↗
▸Other Documents2
▸BISSAFETY MONITORING PLAN1
09/28/2017122878190Open ↗
▸BISPLOT DIAGRAM1
09/28/2017122878190Open ↗