ECB05/14/2026Failure to maintain building in a code-compliant manner. At time of inspection, conditions consistent with violation #3914341M issued 3/30/2025 remain at exposure 1, right corner, where cornice is in disrepair$2K due
HPD12/08/2017§ 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING. LOCATED AT APT 2N, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH
HPD12/08/2017§ 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT GAS RANGE. IN THE ENTIRE APARTMENT LOCATED AT APT 4S, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH
HPD12/08/2017§ 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 4S, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH
HPD12/08/2017§ 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT GAS RANGE. IN THE ENTIRE APARTMENT LOCATED AT APT 2N, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH
HPD12/08/2017§ 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING. LOCATED AT APT 2N, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH
HPD12/08/2017§ 27-2033 ADM code provide ready access to buildings heating system boiler room door locked. At basement
HPD11/30/2017§ 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION SUSPENDED CEILING AT PUBLIC HALL STAIRS, 1st STORY
HPD11/30/2017§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT SOUTH WALL AT PUBLIC HALL STAIRS, 1st STORY
HPD11/30/2017§ 27-2045 ADM CODE POST A PROPER NOTICE OF SMOKE DETECTOR REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, AT OR NEAR THE MAIL BOX MISSING AT PUBLIC HALL, 1st STORY
HPD11/30/2017§ 27-2005 HMC: POST, IN A FORM APPROVED BY THE COMMISSIONER, AND MAINTAIN A NOTICE IN A COMMON AREA OF THE BUILDING REGARDING THE PROCEDURES THAT SHOULD BE FOLLOWED WHEN A GAS LEAK IS SUSPECTED AT PUBLIC HALL, 1st STORY
HPD11/30/2017§ 27-2028, 2032 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FROM AN APPROVED CENTRAL HEATING SYSTEM, OR AN APPROVED SYSTEM OF GAS OR ELECTRICAL HEATING IN GOOD OPERATING CONDITION FOR THE DWELLING UNIT IN THE 1st ROOM FROM EAST LOCATED AT APT 2RS, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH
HPD11/30/2017§ 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT THE GAS RANGE IN THE KITCHEN LOCATED AT APT 2RS, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH
HPD11/30/2017§ 27-2046.1 HMC: POST A PROPER NOTICE OF CARBON MONOXIDE DETECTING DEVICE REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, IN A COMMON AREA OF A CLASS A MULTIPLE DWELLING NEAR INSPECTION CERTIFICATE OR PROVIDE NOTICE TO TENANTS IN A PRIVATE DWELLING. AT PUBLIC HALL, 1st STORY
HPD11/30/2017§ 26-1103 ADMIN. CODE: POST AND MAINTAIN A PROPER NOTICE ON WALL OF THE ENTRANCE STORY IN ENGLISH AND SPANISH ON THE AVAILABILITY OF THE AGENCYS HOUSING INFORMATION GUIDE. A SAMPLE NOTICE CAN BE FOUND AT WWW.NYC.GOV/HPD. AT PUBLIC HALL, 1st STORY
HPD11/30/2017§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE SOUTH WALL WITH FIRE RETARDANT MATERIAL AT PUBLIC HALL STAIRS, 1st STORY
HPD11/30/2017§ 27-2005 ADM code properly repair with similar material the broken or defective metal cornice at building front
HPD11/30/2017§ 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION SUSPENDED CEILING AT PUBLIC HALL, 2nd STORY
HPD11/03/2017§ 27-2046.1 HMC: POST A PROPER NOTICE OF CARBON MONOXIDE DETECTING DEVICE REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, IN A COMMON AREA OF A CLASS A MULTIPLE DWELLING NEAR INSPECTION CERTIFICATE OR PROVIDE NOTICE TO TENANTS IN A PRIVATE DWELLING. AT PUBLIC HALL, 1st STORY
HPD11/03/2017§ 27-2045 ADM CODE POST A PROPER NOTICE OF SMOKE DETECTOR REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, AT OR NEAR THE MAIL BOX MISSING AT PUBLIC HALL, 1st STORY
HPD11/03/2017§ 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDINGS HEATING SYSTEM MISSING AT PUBLIC HALL, 1st STORY
HPD11/03/2017§ 27-2104 ADM CODE POST AND MAINTAIN A PROPER SIGN ON WALL OF ENTRANCE STORY SHOWING THE REGISTRATION NUMBER ASSIGNED BY THE DEPARTMENT AND THE ADDRESS OF THE BUILDING. AT PUBLIC HALL, 1st STORY
HPD11/03/2017§ 27-2053 ADM CODE POST SIGN ON WALL OF ENTRANCE STORY BEARING NAME, ADDRESS INCLUDING APARTMENT NUMBER IF ANY, AND TELEPHONE NUMBER OF SUPERINTENDENT, JANITOR OR HOUSEKEEPER. AT PUBLIC HALL, 1st STORY
HPD11/03/2017§ 26-1103 ADMIN. CODE: POST AND MAINTAIN A PROPER NOTICE ON WALL OF THE ENTRANCE STORY IN ENGLISH AND SPANISH ON THE AVAILABILITY OF THE AGENCYS HOUSING INFORMATION GUIDE. A SAMPLE NOTICE CAN BE FOUND AT WWW.NYC.GOV/HPD. AT PUBLIC HALL, 1st STORY
HPD02/22/2011Section 27-2040 ADM code provide adequate lighting at or near the outside of the front entranceway of the building and keep same burning from sunset every day to sunrise on the day following 200 watts
HPD10/02/2010Section 27-2040 ADM code provide adequate lighting at or near the outside of the front entranceway of the building and keep same burning from sunset every day to sunrise on the day following , 100 watts required.
HPD03/20/2006SECTION 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF NO VENTILATION IN THE BATHROOM LOCATED AT APT 3N, 3rd STORY, APARTMENT AT NORTH
HPD03/20/2006SECTION 27-2005, 2007 ADM CODE ARRANGE AND MAKE SELF-CLOSING THE DOORS , IN THE ENTRANCE LOCATED AT APT 3N, 3rd STORY, APARTMENT AT NORTH
HPD11/10/2004Section 27-2040 ADM code provide adequate lighting at or near the outside of the front entranceway of the building and keep same burning from sunset every day to sunrise on the day following 100 watts lights not on.
ECB03/30/2025Failure to maintain building in code compliant manner. At exposure #1 (right corner) the cornice is is in disrepair with deteriorating materials., repair and/replaceNothing owed — awaiting certificate of correction
ECB04/11/2024Found weil mclain(model# egh 105) gas fired boiler in cellar not registered correct violating condition submit certificate of correctionNothing owed — awaiting certificate of correction
ECB11/02/2013B154,50,51,50B,50C. 50A-second offence, 50B-remove flue pipe fresh airintake; 50C-do not operate hot water heater until all hazardous condi tion are immediately corrected and DOB is call to reinspect to lift thNothing owed — awaiting certificate of correction
ECB11/02/20131,51Nothing owed — awaiting certificate of correction
ECB10/29/2013B154,50A,51. 50A- removed flue/pipe from fresh air ventilation or fresh air intake.Nothing owed — awaiting certificate of correction
ECB10/01/2013B154,15,32A,34A,50A,50B,50C,50D,50E,50F,50G,50H,50I. 50A-hazardous condition metal chimney collapsed; 50B-cannot have more than 1-control ON1/4"pipe; 50C-exposed wires; 50D-holes; 50E-gauge glass dirty; 50F-gapNothing owed — awaiting certificate of correction
Likely answered · the city's own records show a filing, but DOB's feed still lists these as active
DOB11/14/2025Violation issued-failure to file 2024 external low pressure inspectionThe owner has filed since: boiler inspection reports are on file for later years (latest 2026). This one is not shown as answered
DOB06/30/2023Violation issued-failure to file 2021 external low pressure inspectionThe owner has filed since: boiler inspection reports are on file for later years (latest 2026). This one is not shown as answered