← Back
Parochial school, yeshiva
1573 39 STREET
BROOKLYN · BIN 3125863
💬 Discuss this project
1930Year Built
4Stories
W2Building Class
R6Zoning
19,440 sfGross Floor Area
0Units
Rent Stabilized19 Open Violations ▸FDNY Report ↗
Parochial school, yeshiva · 6,000 sf lot · 3.24 FAR built · Flood zone X
Locations of Work
ArchitectureMechanical
Roof3p · 2 filings · 8 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
JERRICK ASSOCIATES704/09/2026
OWNER OF PREMISES=1573 39103/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
ASHER ARCHITECT101/27/2026
PRAMODRAY SHAH, P.E.109/29/2025
ANDREW KATZ ENGINEERS206/06/2024
ASR ENGINEERING PC105/30/2024
SCALAR ARCHITECTURE PC208/06/2019
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
YOEL SHEINBERGER203/21/2026
AE DESIGN SOLUTION403/21/2026
ADVANCED BUILDERS SERVICES103/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
JERRICK ASSOCIATES INCGeneral Contractor204/09/2026
RICHARD NEUElectrical103/22/2026
BROOKLYN CONTRACTOR INCGeneral Contractor104/09/2026
PINNOCK, LENFORDElectrical103/21/2026
PHILIP NABLEGeneral Contractor104/09/2026
TOPLINE NYC INCGeneral Contractor104/09/2026
ELBE CONSTRUCTION LLCGeneral Contractor104/09/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
DAVID KATZ, P.E.6087107/26/2021
Building Lifecycle
All (67)Filed (7)Permit Issued (6)Signed Off (5)Violation (38)Inspection (8)Objection (1)Special Inspection (2)
05/01/2026
Violation issued (HPD, closed)
A
02/11/2026
Objection raised — Other
01/27/2026
Filed — Alteration
B01351550-I1
12/11/2025
Inspection — Fail-Final Curb Cut Non-Directive 14
Fail
View inspection ↗
11/20/2025
Signed off — Alteration
B01058694-I1
11/14/2025
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
11/14/2025
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
10/30/2025
Permit issued — Curb Cut
B01286940-I1-CC
09/29/2025
Filed — Alteration
PROPOSED CURB CUT WORK TYPE, WORK AS PER PLAN.
B01286940-I1
09/22/2025
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
08/28/2025
Inspection — No Access-Final PL - Up to 3 Requested Floors
No Access
View inspection ↗
06/09/2025
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
06/09/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
02/27/2025
Violation issued (ECB, closed)
Boilers
02/27/2025
Violation issued (ECB, closed)
Boilers
02/13/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
12/23/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
10/02/2024
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
09/23/2024
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
09/23/2024
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
08/16/2024
Signed off — Alteration
B01062043-I1
06/21/2024
Permit issued — General Construction
B01062043-I1-GC
06/06/2024
Filed — Alteration
B01062043-I1
05/31/2024
Permit issued — Sidewalk Shed
B01058694-I1-SH
05/30/2024
Filed — Alteration
B01058694-I1
06/30/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
06/30/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
06/30/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
06/30/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
06/20/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
06/20/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
04/25/2023
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
04/25/2023
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
08/05/2021
Signed off — Alteration
HEAT PUMP UNITS ON EXISITNG STEEL DUNNAGE. OBTAIN CERTIFICATE OF COMPLIANCE. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B00560158-I1
07/27/2021
Permit issued — Mechanical Systems
B00560158-I1-MS
07/26/2021
Filed — Alteration
HEAT PUMP UNITS ON EXISITNG STEEL DUNNAGE. OBTAIN CERTIFICATE OF COMPLIANCE. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B00560158-I1
04/15/2021
Signed off — Alteration
INSTALLATION OF SIDEWALK SHED AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B00181045-I1
03/12/2021
Signed off — Alteration
B00194820-I1
08/07/2019
Permit issued — Supported Scaffold
B00194820-I1-SF
08/06/2019
Filed — Alteration
B00194820-I1
07/17/2019
Special inspection requirement — Final
JULIO SALCEDO-FERNANDEZ
07/03/2019
Permit issued — Sidewalk Shed
B00181045-I1-SH
07/02/2019
Filed — Alteration
INSTALLATION OF SIDEWALK SHED AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B00181045-I1
06/17/2019
Special inspection requirement — Final
JULIO SALCEDO-FERNANDEZ
03/01/2013
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
12/31/2009
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
12/31/2009
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
12/31/2009
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
01/06/2006
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
01/06/2006
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
01/06/2006
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
01/06/2006
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
01/31/2005
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
05/04/1998
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
05/04/1998
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
05/04/1998
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
09/16/1997
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
09/16/1997
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
09/16/1997
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
07/25/1994
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
Latest 60 of 67 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWCurb CutPermit IssuedBROOKLYN CONTRACTOR INC10/30/2025
DOB NOWGeneral ConstructionSigned-offELBE CONSTRUCTION LLC06/21/2024
DOB NOWSidewalk ShedSigned-offTOPLINE NYC INC05/31/2024
DOB NOWMechanical SystemsSigned-offPHILIP NABLE07/27/2021
DOB NOWSupported ScaffoldSigned-offGE 2A CONSTRUCTION08/07/2019
DOB NOWSidewalk ShedSigned-offGE 2A CONSTRUCTION07/03/2019
BIS—ISSUEDYCK CONTRACTING CORP06/30/2009
BISSPISSUEDTMS PLUMBING & HTG CORP04/10/2009
BISEQISSUEDJERRICK ASSOCIATES INC12/18/2008
BISPLISSUEDBMB MECHANICAL CORP.09/10/2008
BIS—ISSUEDYCK CONTRACTING CORP08/21/2008
BISFPISSUEDFIREMASTERS04/26/2007
BISFPISSUEDB&J FIRE INC T/A FIRE MASTERS04/21/1997
BISPLISSUEDBEST PLUMBING PARTNERS09/18/1996
BISOTISSUEDYESHIVA DERECH CHAIM09/17/1996
2 projects · most recent 06/15/2024
FiledStatusContractorScope
06/15/2024CompleteRICHARD NEU—
07/02/2019CompleteBOROWIDE ELECT'L CONTR'S—
▾Field Inspections (DOB CAP) — 8
DateTypeResultReport
12/11/2025Fail-Final Curb Cut Non-Directive 14FailView ↗
09/22/2025Certified Gas-Gas-Piping-RoughingCertifiedView ↗
08/28/2025No Access-Final PL - Up to 3 Requested FloorsNo AccessView ↗
06/09/2025Certified Gas-Gas-Piping-RoughingCertifiedView ↗
06/09/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
02/13/2025Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
12/23/2024Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
10/02/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
▾Special Inspection Requirements (DOB NOW) — 2
DateRequirementInspectorRole
07/17/2019FinalJULIO SALCEDO-FERNANDEZprogress
06/17/2019FinalJULIO SALCEDO-FERNANDEZprogress
▾Documents — 90 on file (BIS + DOB NOW)
▸Plans & Drawings7
▸DOB NOWPlans/Sketch5
09/01/2026B00560158-I1Request digital key ↗
08/25/2026B01058694-I1Request digital key ↗
08/24/2026B01062043-I1Request digital key ↗
Showing 3 of 5 on file for this type
▸DOB NOWPlans/Sketch - Sidewalk Shed1
09/02/2026B00181045-I1Request digital key ↗
▸DOB NOWPlans/Sketch - Supported Scaffold1
09/02/2026B00194820-I1Request digital key ↗
▸Applications & Permits14
▸BISPLAN / WORK APPROVAL APPLICATION7
10/23/2009320000020Open ↗
07/23/2009310145955Open ↗
06/04/2009320020721Open ↗
Showing 3 of 7 on file for this type
▸BISWORK PERMIT APPLICATION5
10/20/2009310145955Open ↗
04/10/2009320000020Open ↗
12/19/2008310238150Open ↗
Showing 3 of 5 on file for this type
▸BISPLACE OF ASSEMBLY1
09/17/2014320955962Open ↗
▸BISCERTIFICATE OF OCCUPANCY: APPLICATION1
09/04/2009310145955Open ↗
▸Seals & Professional Certifications23
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION10
10/30/2014320955962Open ↗
10/30/2014320955962Open ↗
10/12/2010320000020Open ↗
Showing 3 of 10 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature7
08/25/2026B01058694-I1Open ↗
08/24/2026B01062043-I1Open ↗
08/20/2026B01286940-I1Open ↗
Showing 3 of 7 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM2
03/27/2009320000020Open ↗
12/19/2008310238150Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST2
03/27/2009320000020Open ↗
12/19/2008310238150Open ↗
▸DOB NOWProgress Inspector Seal & Signature2
09/01/2026B00181045-I1Open ↗
08/31/2026B00194820-I1Open ↗
▸Trade Schedules & Equipment7
▸BISSCHEDULE B - PLUMBING4
10/23/2009320000020Open ↗
07/23/2009310145955Open ↗
03/27/2009320000020Open ↗
Showing 3 of 4 on file for this type
▸BISSELF-CERT PLUMBING NOTICE2
02/18/2010310145955Open ↗
11/09/2009320000020Open ↗
▸BISSPRINKLER INSP REPORT : FP-851
11/09/2009320000020Open ↗
▸Safety & Tenant Protection2
▸BISST-1: Street Tree Checklist2
07/29/2008310145955Open ↗
03/27/2009320000020Open ↗
▸Environmental & Asbestos5
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'3
06/04/2009320020721Open ↗
03/18/2009310305844Open ↗
07/09/2008310145955Open ↗
▸BISASBESTOS EXEMPTION CERTIFICATION LETTER1
12/19/2008310238150Open ↗
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/24/2026B01062043-I1Open ↗
▸Energy Compliance2
▸BISEMERGENCY LIGHTING (IF NOT IN COMPLIANCE WITH MEMEO 2-18-81)1
10/30/2014320955962Open ↗
▸DOB NOWEN2: As Built Energy Analysis.1
08/13/2026B00560158-I1Open ↗
▸Approvals, Objections & Sign-offs20
▸BISADMINISTRATIVE OBJECTIONS6
09/17/2014320955962Open ↗
06/04/2009320020721Open ↗
03/27/2009320000020Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWFee Exempt Supporting Document - DOF ACRIS report or BIB letter6
08/13/2026B01286940-I1Open ↗
08/13/2026B01062043-I1Open ↗
08/13/2026B01351550-I1Open ↗
Showing 3 of 6 on file for this type
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST5
11/17/2010310238150Open ↗
10/12/2010320000020Open ↗
09/03/2010310238150Open ↗
Showing 3 of 5 on file for this type
▸BISFLAME SPREAD/FIRE LETTER1
10/30/2014320955962Open ↗
▸BISLETTERS - SUPPORTING DOCUMENTATION1
11/17/2010310238150Open ↗
▸BISSCHEDULE A - OCCUPANCY / USE1
05/23/2008310145955Open ↗
▸Cost, Insurance & Ownership4
▸BISCOST AFFIDAVIT4
10/12/2010320000020Open ↗
06/04/2009320020721Open ↗
03/27/2009320000020Open ↗
Showing 3 of 4 on file for this type
▸Filing & Intake Forms6
▸BISEFILING COVER SHEET5
06/04/2009320020721Open ↗
03/27/2009320000020Open ↗
03/18/2009310305844Open ↗
Showing 3 of 5 on file for this type
▸BISADDITIONAL INFORMATION1
11/16/2009310145955Open ↗