1899Year Built
2Stories
B9Building Class
R6Zoning
2,109 sfGross Floor Area
2Units
8 Open Violations ▸FDNY Report ↗
Miscellaneous two family · 1,088 sf lot · 1.94 FAR built · Flood zone X
Locations of Work
ArchitectureElectricalGeneral
Roof2p · 1 filing · 9 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
HPD203/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
TOM PETERSEN ARCHITECT, LLC203/18/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
SUNCO CAPITAL403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
BERGER QUALITY ELEC'L CONElectrical103/22/2026
FRANK, SEYMOURElectrical103/21/2026
SUNCO CAPITAL LLCGeneral Contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
THOMAS PETERSEN ARCHITECT7854203/18/2025
Building Lifecycle
All (18)Filed (2)Permit Issued (1)Signed Off (1)Violation (8)Special Inspection (6)
11/24/2025
Violation issued (HPD, open)
I
05/23/2025
Signed off — Alteration
INSTALLATION OF SOLAR PANELS ON ROOF. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
B01169102-I1
03/19/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
TOM PETERSEN
03/19/2025
Special inspection requirement — Flood Zone Compliance (attach FEMA elevation/dry floodproofing certificate where applicable)
TOM PETERSEN
03/19/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
TOM PETERSEN
03/19/2025
Special inspection requirement — Final
TOM PETERSEN
03/19/2025
Special inspection requirement — Energy Code Compliance Inspections
TOM PETERSEN
03/19/2025
Special inspection requirement — Air barrier - visual inspection
TOM PETERSEN
03/18/2025
Filed — Alteration
INSTALLATION OF SOLAR PANELS ON ROOF. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
B01169102-P1
02/04/2025
Permit issued — Solar
B01169102-I1-SL
01/24/2025
Filed — Alteration
INSTALLATION OF SOLAR PANELS ON ROOF. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
B01169102-I1
12/03/2024
Violation issued (HPD, open)
I
11/28/2023
Violation issued (HPD, open)
I
11/17/2022
Violation issued (HPD, open)
I
03/16/2022
Violation issued (HPD, open)
I
04/21/2021
Violation issued (HPD, open)
I
11/08/2019
Violation issued (HPD, open)
I
01/10/2018
Violation issued (HPD, open)
I
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarSigned-offSUNCO CAPITAL LLC02/04/2025
BISPLISSUEDQNS,THE MECHANICAL CORP11/12/2002
BIS—ISSUEDPENTA HOUSING GROUP07/25/2002
BISEQISSUEDPENTA HOUSING GROUP07/25/2002
1 project · most recent 01/27/2025
FiledStatusContractorScope
01/27/2025CompleteBERGER QUALITY ELEC'L CON—
▾Special Inspection Requirements (DOB NOW) — 6
DateRequirementInspectorRole
03/19/2025Structural Stability – Alterations of existing buildingsTOM PETERSENspecial
03/19/2025Flood Zone Compliance (attach FEMA elevation/dry floodproofing certificate where applicable)TOM PETERSENspecial
03/19/2025Fire-Resistant Penetrations and JointsTOM PETERSENspecial
03/19/2025FinalTOM PETERSENprogress
03/19/2025Energy Code Compliance InspectionsTOM PETERSENprogress
03/19/2025Air barrier - visual inspectionTOM PETERSENenergy_progress
▾Documents — 9 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/22/2026B01169102-P1Request digital key ↗
08/22/2026B01169102-I1Request digital key ↗
▸Seals & Professional Certifications6
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/22/2026B01169102-P1Open ↗
08/22/2026B01169102-I1Open ↗
▸DOB NOWProgress Inspector Seal & Signature2
08/22/2026B01169102-I1Open ↗
08/22/2026B01169102-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
08/22/2026B01169102-I1Open ↗
08/22/2026B01169102-I1Open ↗
▸Approvals, Objections & Sign-offs1
▸DOB NOWUtility Company Final Acceptance Letter1
08/13/2026B01169102-I1Open ↗