← Back
Primarily 3 family with 1 store or office
158 9 AVENUE
MANHATTAN · Chelsea-Hudson Yards · BIN 1013241
💬 Discuss this project
1852Year Built
4Stories
S3Building Class
C2-6AZoning
4,448 sfGross Floor Area
4Units
Rent Stabilized0 Open Violations
Primarily 3 family with 1 store or office · Owner of record: SEMINARY ASSOCIATES LLC · 1,760 sf lot · 2.53 FAR built · Flood zone X
Locations of Work
ArchitectureMechanicalPlumbing
Permit Issued — active, not yet Signed-off
RoofUnder Construction1 filing · 20 docs
Floor 4Under Construction1 filing · 20 docs
Floor 3Under Construction1 filing · 20 docs
Floor 2Under Construction1 filing · 20 docs
Floor 1Under Construction4p · 1 filing · 20 docs
CellarUnder Construction4p · 1 filing · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
SEMINARY ASSOCIATES1403/22/2026
▾Design Consultants (Architect / Engineer of Record)
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
BOYD CONSULTING203/21/2026
Rigid Structural Design, LLC203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
FRANCO REMODELING CORPGeneral Contractor404/09/2026
STEWART, DUDLEYElectrical103/21/2026
FINE LINE MIC CORPGeneral Contractor104/09/2026
ASHLEY, ANTHONYElectrical103/21/2026
MILLENNIUM HVAC NY INCGeneral Contractor108/14/2026
UNIQUE FIRE SYSTEMS INCGeneral Contractor108/11/2026
CROSSFIELD PLBG.&HTGPlumbing106/28/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
CMSC, INC6098506/26/2026
Building Lifecycle
All (38)Filed (7)Permit Issued (7)Signed Off (2)Violation (5)Inspection (6)Special Inspection (11)
08/13/2026
Permit issued — Mechanical Systems
M01110984-S2-MS
08/10/2026
Permit issued — Mechanical Systems
M01110984-I1-MS
07/31/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
EDUARD GRINFELD
07/31/2026
Special inspection requirement — Tenant Protection Plan Compliance
EDUARD GRINFELD
06/26/2026
Filed — Alteration
INTERIOR RENOVATION FOR EX. RESTAURANT ON 1ST FLOOR; AND TO ADD FIRE RATED WALL AND DOOR FOR EX. STAIRWAY ON CELLAR. REPLACE BLOWER ON ROOF W/ CHIMNEY CONNECTING EX. 1ST FLOOR DUCT WORK EXHAUST FROM 1ST FLOOR TO ROOF. REPLACE STEPCASE AT REAR YARD. NO CHA
M01110984-S2
06/25/2026
Filed — Alteration
INTERIOR RENOVATION FOR EX. RESTAURANT ON 1ST FLOOR; AND TO ADD FIRE RATED WALL AND DOOR FOR EX. STAIRWAY ON CELLAR. REPLACE BLOWER ON ROOF W/ CHIMNEY CONNECTING EX. 1ST FLOOR DUCT WORK EXHAUST FROM 1ST FLOOR TO ROOF. REPLACE STEPCASE AT REAR YARD. NO CHA
M01110984-P1
06/25/2026
Filed — Alteration
INTERIOR RENOVATION FOR EX. RESTAURANT ON 1ST FLOOR; AND TO ADD FIRE RATED WALL AND DOOR FOR EX. STAIRWAY ON CELLAR. REPLACE BLOWER ON ROOF W/ CHIMNEY CONNECTING EX. 1ST FLOOR DUCT WORK EXHAUST FROM 1ST FLOOR TO ROOF. REPLACE STEPCASE AT REAR YARD. NO CHA
M01110984-P2
06/24/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
EDUARD GRINFELD
06/24/2026
Special inspection requirement — HVAC-R and service water heating system controls
EDUARD GRINFELD
06/24/2026
Special inspection requirement — Duct leakage testing, insulation and design
EDUARD GRINFELD
06/24/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
EDUARD GRINFELD
06/24/2026
Special inspection requirement — Tenant Protection Plan Compliance
EDUARD GRINFELD
06/24/2026
Special inspection requirement — Energy Code Compliance Inspections
EDUARD GRINFELD
06/24/2026
Special inspection requirement — HVAC-R and service water heating equipment
EDUARD GRINFELD
03/17/2026
Inspection — Fail-Final PL - Up to 3 Requested Floors
Fail
View inspection ↗
01/20/2026
Permit issued — Plumbing
M01110984-S1-PL
01/16/2026
Signed off — Alteration
M01096724-I1
12/12/2025
Permit issued — Mechanical Systems
M01110984-I1-GC
12/12/2025
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
11/07/2025
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
11/07/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
11/05/2025
Filed — Alteration
INTERIOR RENOVATION FOR EX. RESTAURANT ON 1ST FLOOR; AND TO ADD FIRE RATED WALL AND DOOR FOR EX. STAIRWAY ON CELLAR. REPLACE BLOWER ON ROOF W/ CHIMNEY CONNECTING EX. 1ST FLOOR DUCT WORK EXHAUST FROM 1ST FLOOR TO ROOF. REPLACE STEPCASE AT REAR YARD. NO CHA
M01110984-S1
09/19/2025
Special inspection requirement — Final
BENJAMIN SASSON
09/19/2025
Special inspection requirement — Mechanical Systems
EDUARD GRINFELD
07/16/2025
Permit issued — Construction Fence
M01096724-I1-FN
04/28/2025
Inspection — Certified Storm Drainage-ST-Piping-Underground
Certified
View inspection ↗
04/28/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
02/13/2025
Signed off — Alteration
Limited facade and masonry repairs as per plans. No change in use, egress or occupancy is required under this application.
M01110534-I1
10/17/2024
Permit issued — General Construction
M01110534-I1-GC
10/01/2024
Filed — Alteration
Limited facade and masonry repairs as per plans. No change in use, egress or occupancy is required under this application.
M01110534-I1
09/26/2024
Filed — Alteration
INTERIOR RENOVATION FOR EX. RESTAURANT ON 1ST FLOOR; AND TO ADD FIRE RATED WALL AND DOOR FOR EX. STAIRWAY ON CELLAR. REPLACE BLOWER ON ROOF W/ CHIMNEY CONNECTING EX. 1ST FLOOR DUCT WORK EXHAUST FROM 1ST FLOOR TO ROOF. REPLACE STEPCASE AT REAR YARD. NO CHA
M01110984-I1
08/15/2024
Filed — Alteration
M01096724-I1
08/15/2024
Permit issued — Construction Fence
M01096724-I1-FN
10/28/2008
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
09/09/2002
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/27/2002
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/18/1994
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/18/1993
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsPermit IssuedMILLENNIUM HVAC NY INC08/13/2026
DOB NOWMechanical SystemsPermit IssuedUNIQUE FIRE SYSTEMS INC08/10/2026
DOB NOWPlumbingPermit IssuedCROSSFIELD PLBG.&HTG01/20/2026
DOB NOWMechanical SystemsPermit IssuedFINE LINE MIC12/12/2025
DOB NOWConstruction FenceSigned-offFRANCO REMODELING CORP07/16/2025
DOB NOWGeneral ConstructionSigned-offFRANCO REMODELING CORP10/17/2024
DOB NOWConstruction FenceSigned-offFRANCO REMODELING CORP08/15/2024
BISOTISSUEDNEW GENERATION CONSTRUCTI06/27/2012
BISPLISSUEDADRIATIC PLBG & HTG CORP03/21/2003
BISPLISSUEDCOLBREN PLBG & HTG INC12/12/2002
BISMHISSUEDSHAN'S HOME IMPROVEMENT11/12/2002
BISOTISSUEDSPANIER CONSTRUCTION LLC07/15/2002
BISPLISSUEDFLYTIGER P & H LTD04/30/2002
BISFPISSUEDNEW YORK BUSINESS FIRE SYSTEM IN03/25/2002
BISOTISSUEDSPANIER CONSTRUCTION LLC03/04/2002
BISPLISSUEDFLYTIGER P & H LTD12/31/2001
BISOTISSUEDRESTAURANT CONSTRUCTION MANAGER10/26/2001
1 project · most recent 06/26/2026
Heating and Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
06/26/2026Permit IssuedMILLENNIUM HVAC NY INCHeating and Air Conditioning Systems
Heat / Cool
Mitsubishi Electric Model# PEAD-AA36NL 36,000 BTU · Vrf Indoor ×2
Model# SUZ-AA36NL 36,000 BTU · Heat Pump Outdoor ×2
1 project · most recent 06/26/2026
Gas Water/Sanitary
FiledStatusContractorScope
06/26/2026Permit IssuedCROSSFIELD PLBG.&HTGGas, Water/Sanitary
1 project · most recent 03/18/2026
General Wiring
FiledStatusContractorScope
03/18/2026Permit IssuedHI-RITE ELECTRIC CORPGeneral Wiring
1 project · most recent 06/26/2026
Tenant Protection Plan 72 Hour
FiledStatusContractorScope
06/26/2026Permit IssuedMILLENNIUM HVAC NY INCTenant Protection Plan 72 Hour
▾Field Inspections (DOB CAP) — 6
DateTypeResultReport
03/17/2026Fail-Final PL - Up to 3 Requested FloorsFailView ↗
12/12/2025Pass-Final PL - Up to 3 Requested FloorsPassView ↗
11/07/2025Certified Gas-Gas-Piping-RoughingCertifiedView ↗
11/07/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
04/28/2025Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
04/28/2025Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 11
DateRequirementInspectorRole
07/31/2026Fire-Resistant Penetrations and JointsEDUARD GRINFELDspecial
07/31/2026Tenant Protection Plan ComplianceEDUARD GRINFELDspecial
06/24/2026HVAC-R and service water piping design and insulationEDUARD GRINFELDenergy_progress
06/24/2026HVAC-R and service water heating system controlsEDUARD GRINFELDenergy_progress
06/24/2026Duct leakage testing, insulation and designEDUARD GRINFELDenergy_progress
06/24/2026Fire-Resistant Penetrations and JointsEDUARD GRINFELDspecial
06/24/2026Tenant Protection Plan ComplianceEDUARD GRINFELDspecial
06/24/2026Energy Code Compliance InspectionsEDUARD GRINFELDprogress
06/24/2026HVAC-R and service water heating equipmentEDUARD GRINFELDenergy_progress
09/19/2025FinalBENJAMIN SASSONprogress
09/19/2025Mechanical SystemsEDUARD GRINFELDspecial
▾Documents — 51 on file (BIS + DOB NOW)
▸Plans & Drawings5
▸DOB NOWPlans/Sketch5
08/26/2026M01096724-I1Request digital key ↗
08/26/2026M01110534-I1Request digital key ↗
08/21/2026M01110984-P1Request digital key ↗
Showing 3 of 5 on file for this type
▸Applications & Permits10
▸BISPLAN / WORK APPROVAL APPLICATION5
05/07/2025102502294Open ↗
04/18/2025102502294Open ↗
03/15/2023102502294Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWLPC Approval/Permit4
08/21/2026M01110984-P1Open ↗
08/21/2026M01110984-S2Open ↗
08/21/2026M01110984-P2Open ↗
Showing 3 of 4 on file for this type
▸BISWORK PERMIT APPLICATION1
06/28/2012120986353Open ↗
▸Seals & Professional Certifications13
▸DOB NOWDPL-1: Design Professional Seal & Signature5
08/26/2026M01096724-I1Open ↗
08/26/2026M01110534-I1Open ↗
08/21/2026M01110984-P1Open ↗
Showing 3 of 5 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION3
02/27/2014120986353Open ↗
02/27/2014120986353Open ↗
02/24/2012120986353Open ↗
▸DOB NOWProgress Inspector Seal & Signature3
09/23/2026M01110984-S2Open ↗
09/23/2026M01110984-S2Open ↗
08/27/2026M01110984-S2Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
09/23/2026M01110984-S2Open ↗
08/25/2026M01110984-S1Open ↗
▸Environmental & Asbestos5
▸DOB NOWDEP ACP-5: Asbestos Assessment Report4
08/26/2026M01110534-I1Open ↗
08/21/2026M01110984-S2Open ↗
08/21/2026M01110984-P2Open ↗
Showing 3 of 4 on file for this type
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'1
02/24/2012120986353Open ↗
▸Energy Compliance1
▸BISTECHNICAL REPORT: ENERGY1
02/24/2012120986353Open ↗
▸Inspections & Test Reports4
▸BISTECHNICAL REPORT: RESPONSIBILITY4
05/06/2025102502294Open ↗
05/06/2025102502294Open ↗
05/06/2025102502294Open ↗
Showing 3 of 4 on file for this type
▸Approvals, Objections & Sign-offs7
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST2
05/07/2025102502294Open ↗
02/27/2014120986353Open ↗
▸DOB NOWLandmark Approval2
08/13/2026M01110984-S1Open ↗
08/13/2026M01110984-I1Open ↗
▸BISLANDMARKS APPROVAL1
06/18/2012120986353Open ↗
▸BISADMINISTRATIVE OBJECTIONS1
02/24/2012120986353Open ↗
▸BISLANDMARKS SIGNOFF1
05/07/2025102502294Open ↗
▸Cost, Insurance & Ownership2
▸BISCOST AFFIDAVIT2
02/27/2014120986353Open ↗
02/24/2012120986353Open ↗
▸Filing & Intake Forms2
▸BISEFILING COVER SHEET1
02/24/2012120986353Open ↗
▸BISADDITIONAL INFORMATION1
02/12/2014120986353Open ↗
▸Other Documents2
▸BISEXTERNAL FORMS - SUPPORTING DOCUMENTATION1
05/07/2025102502294Open ↗
▸DOB NOWProof of Historic Building1
08/13/2026M01110534-I1Open ↗