← Back
Primarily 5-6 family with 1 store or office
158 SUMMIT STREET
BROOKLYN · BIN 3005057
💬 Discuss this project
1900Year Built
4Stories
S5Building Class
R6BZoning
6,500 sfGross Floor Area
6Units
10 Open Violations ▸
Primarily 5-6 family with 1 store or office · Owner of record: 629 HICKS STREET LLC · 2,500 sf lot · 2.6 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbing
Permit Issued — active, not yet Signed-off
RoofUnder Construction14p · 1 filing · 20 docs
Floor 3Under Construction39p · 1 filing · 20 docs
Floor 2Under Construction39p · 1 filing · 20 docs
Floor 1Under Construction39p · 1 filing · 20 docs
CellarUnder Construction34p · 1 filing · 20 docs
BasementUnder Construction31p · 1 filing · 20 docs
1 job · most recent 04/28/2026
Heating and Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
04/28/2026Permit IssuedARTUR KALAJHeating and Air Conditioning Systems
Heat / Cool
Lg ZRUM060GSS0 5 tons · Vrf Outdoor ×2
1 job · most recent 05/06/2026
General Wiring
FiledStatusContractorScope
05/06/2026Permit IssuedTITANIUM ELECTRICAL CORPGeneral Wiring
1 job · most recent 04/28/2026
Wood
FiledStatusContractorScope
04/28/2026Permit IssuedARTUR KALAJWood
Building Lifecycle
All (79)Filed (4)Permit Issued (4)Violation (10)Inspection (6)Objection (30)Special Inspection (25)
08/19/2026
Inspection — Fail-Final PL - Up to 3 Requested Floors
Fail
View inspection ↗
08/13/2026
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
07/16/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
05/26/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
05/22/2026
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
05/19/2026
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
05/06/2026
Violation issued (HPD, open)
A
05/05/2026
Permit issued — Mechanical Systems
B01318232-S2-MS
05/05/2026
Permit issued — Structural
B01318232-S3-ST
05/05/2026
Permit issued — General Construction
B01318232-I1-GC
05/04/2026
Permit issued — Plumbing
B01318232-S1-PL
04/28/2026
Filed — Alteration CO
STRUCTURAL WORK FILED IN CONJUNCTION WITH EXISTING BUILDING ALTERATION APPLICATION INCLUDING REINFORCEMENT OF EXISTING WOOD FLOOR AND ROOF FRAMING, TEMPORARY SHORING WORK FOR RELIEF WALL WORK, AND RELIEF WOOD WALL FRAMING WORK.
B01318232-S2
04/28/2026
Filed — Alteration CO
STRUCTURAL WORK FILED IN CONJUNCTION WITH EXISTING BUILDING ALTERATION APPLICATION INCLUDING REINFORCEMENT OF EXISTING WOOD FLOOR AND ROOF FRAMING, TEMPORARY SHORING WORK FOR RELIEF WALL WORK, AND RELIEF WOOD WALL FRAMING WORK.
B01318232-S1
04/28/2026
Special inspection requirement — Maintenance information
Brian Bisram
04/28/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
ILYA VILNITS
04/28/2026
Special inspection requirement — Shutoff dampers
Brian Bisram
04/28/2026
Special inspection requirement — Permanent certificate
Brian Bisram
04/28/2026
Special inspection requirement — Permanent certificate
Brian Bisram
04/21/2026
Objection resolved — Resolved
03/26/2026
Objection resolved — Addressed
03/26/2026
Objection resolved — Addressed
03/26/2026
Objection resolved — Addressed
03/26/2026
Objection resolved — Addressed
03/25/2026
Objection raised — Admin
03/25/2026
Objection raised — Admin
03/25/2026
Objection raised — Structural
03/25/2026
Objection raised — Admin
03/25/2026
Objection raised — Admin
03/19/2026
Objection resolved — Addressed
03/19/2026
Special inspection requirement — HVAC-R and service water heating system controls
Brian Bisram
03/19/2026
Special inspection requirement — HVAC-R and service water heating equipment
Brian Bisram
03/19/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
Brian Bisram
03/13/2026
Filed — Alteration CO
STRUCTURAL WORK FILED IN CONJUNCTION WITH EXISTING BUILDING ALTERATION APPLICATION INCLUDING REINFORCEMENT OF EXISTING WOOD FLOOR AND ROOF FRAMING, TEMPORARY SHORING WORK FOR RELIEF WALL WORK, AND RELIEF WOOD WALL FRAMING WORK.
B01318232-S3
03/12/2026
Special inspection requirement — Structural Cold-Formed Steel
Nizar Khoury
03/12/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
Nizar Khoury
03/12/2026
Special inspection requirement — Final
Nizar Khoury
03/12/2026
Special inspection requirement — Structural Wood Frame
Nizar Khoury
03/03/2026
Objection resolved — Addressed
03/03/2026
Objection resolved — Addressed
03/03/2026
Special inspection requirement — HVAC-R and service water heating system controls
Brian Bisram
03/03/2026
Special inspection requirement — Mechanical Systems
Brian Bisram
03/03/2026
Special inspection requirement — Energy Code Compliance Inspections
Brian Bisram
03/03/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
Brian Bisram
03/03/2026
Special inspection requirement — HVAC-R and service water heating equipment
Brian Bisram
03/03/2026
Special inspection requirement — Maintenance information
Brian Bisram
03/03/2026
Special inspection requirement — Final
Brian Bisram
03/03/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
ILYA VILNITS
02/04/2026
Objection resolved — Addressed
02/04/2026
Objection resolved — Addressed
02/04/2026
Objection resolved — Addressed
02/03/2026
Objection raised — Mechanical
01/24/2026
Objection resolved — Addressed
01/14/2026
Objection raised — Scope
12/23/2025
Objection resolved — Addressed
12/19/2025
Objection resolved — Addressed
12/19/2025
Objection resolved — Addressed
12/12/2025
Objection raised — Admin
12/12/2025
Objection raised — Cost
12/12/2025
Objection raised — Fire_Protection
12/10/2025
Objection raised — Admin
Latest 60 of 79 events.
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
GREEN SOLUTIONS ENGINEERING & ENERG204/28/2026
URBAN ENGINEERING, PC103/13/2026
THE VILNITS GROUP111/19/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
URBAN ENGINEERING, PC203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
ARTUR KALAJGeneral Contractor307/03/2026
AQUEDUCT MECHANICAL CORPPlumbing106/28/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
GREEN SOLUTIONS ENGINEERI5478104/28/2026
THE VILNITS GROUP LLC1223304/28/2026
URBAN ENGINEERING, PC2575103/13/2026
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsPermit IssuedARTUR KALAJ05/05/2026
DOB NOWStructuralPermit IssuedARTUR KALAJ05/05/2026
DOB NOWGeneral ConstructionPermit IssuedARTUR KALAJ05/05/2026
DOB NOWPlumbingPermit IssuedAQUEDUCT MECHANICAL CORP05/04/2026
BISOTISSUEDMANNIO INC05/30/2001
▾Field Inspections (DOB CAP) — 6
DateTypeResultReport
08/19/2026Fail-Final PL - Up to 3 Requested FloorsFailView ↗
08/13/2026Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
07/16/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
05/26/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
05/22/2026Certified Gas-Gas-Piping-RoughingCertifiedView ↗
05/19/2026Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 25
DateRequirementInspectorRole
04/28/2026Maintenance informationBrian Bisramenergy_progress
04/28/2026Fire-Resistant Penetrations and JointsILYA VILNITSspecial
04/28/2026Shutoff dampersBrian Bisramenergy_progress
04/28/2026Permanent certificateBrian Bisramenergy_progress
04/28/2026Permanent certificateBrian Bisramenergy_progress
03/19/2026HVAC-R and service water heating system controlsBrian Bisramenergy_progress
03/19/2026HVAC-R and service water heating equipmentBrian Bisramenergy_progress
03/19/2026HVAC-R and service water piping design and insulationBrian Bisramenergy_progress
03/12/2026Structural Cold-Formed SteelNizar Khouryspecial
03/12/2026Structural Stability – Alterations of existing buildingsNizar Khouryspecial
03/12/2026FinalNizar Khouryprogress
03/12/2026Structural Wood FrameNizar Khouryprogress
03/03/2026HVAC-R and service water heating system controlsBrian Bisramenergy_progress
03/03/2026Mechanical SystemsBrian Bisramspecial
03/03/2026Energy Code Compliance InspectionsBrian Bisramprogress
03/03/2026HVAC-R and service water piping design and insulationBrian Bisramenergy_progress
03/03/2026HVAC-R and service water heating equipmentBrian Bisramenergy_progress
03/03/2026Maintenance informationBrian Bisramenergy_progress
03/03/2026FinalBrian Bisramprogress
03/03/2026Fire-Resistant Penetrations and JointsILYA VILNITSspecial
11/15/2025Interior lighting powerILYA VILNITSenergy_progress
11/15/2025Lighting in dwelling unitsILYA VILNITSenergy_progress
11/15/2025Lighting controlsILYA VILNITSenergy_progress
11/15/2025Fire-Resistance Rated ConstructionILYA VILNITSprogress
11/15/2025Fire-Resistant Penetrations and JointsILYA VILNITSspecial
▾Documents — 34 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch4
08/17/2026B01318232-S3Request digital key ↗
08/17/2026B01318232-S2Request digital key ↗
08/17/2026B01318232-S1Request digital key ↗
Showing 3 of 4 on file for this type
▸Applications & Permits1
▸BISPLAN / WORK APPROVAL APPLICATION1
08/08/2023322113315Open ↗
▸Seals & Professional Certifications18
▸DOB NOWProgress Inspector Seal & Signature8
09/02/2026B01318232-I1Open ↗
09/02/2026B01318232-I1Open ↗
08/27/2026B01318232-S3Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature6
09/02/2026B01318232-I1Open ↗
08/27/2026B01318232-S3Open ↗
08/27/2026B01318232-S3Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature4
08/17/2026B01318232-S3Open ↗
08/17/2026B01318232-S2Open ↗
08/17/2026B01318232-S1Open ↗
Showing 3 of 4 on file for this type
▸Safety & Tenant Protection1
▸DOB NOWStreet Tree Checklist1
08/13/2026B01318232-I1Open ↗
▸Environmental & Asbestos5
▸DOB NOWDEP ACP-5: Asbestos Assessment Report5
08/17/2026B01318232-S1Open ↗
08/17/2026B01318232-S3Open ↗
08/17/2026B01318232-S2Open ↗
Showing 3 of 5 on file for this type
▸Approvals, Objections & Sign-offs1
▸BISSCHEDULE A - OCCUPANCY / USE1
08/08/2023322113315Open ↗
▸Filing & Intake Forms2
▸BISADDITIONAL INFORMATION1
08/08/2023322113315Open ↗
▸BISEFILING COVER SHEET1
08/08/2023322113315Open ↗
▸Other Documents2
▸BISPLOT DIAGRAM1
08/08/2023322113315Open ↗
▸DOB NOWProperty Ownership Certification1
08/13/2026B01318232-I1Open ↗