← Back
One story retail building
1580 FULTON STREET
BROOKLYN · Bedford-Stuyvesant (East) · BIN 3047956
💬 Discuss this project
1920Year Built
1Stories
K1Building Class
R7DZoning
900 sfGross Floor Area
1Units
One story retail building · 1,600 sf lot · 0.56 FAR built · Flood zone X
Locations of Work
ArchitectureElectricalMechanicalPlumbing
Permit Issued — active, not yet Signed-off
RoofUnder Construction7p · 1 filing · 20 docs
Floor 1Under Construction13p · 1 filing · 20 docs
CellarUnder Construction20p · 1 filing · 20 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
NEW AIR SOLUTION INC.705/04/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
KLE CONSTRUCTION INCGeneral Contractor303/21/2026
XH&RC PLBG AND HTG INCPlumbing210/02/2026
UNITED ELEC'L CONT'G CORPElectrical103/22/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
NEW AIR SOLUTION INC8418705/04/2026
Building Lifecycle
All (51)Filed (7)Permit Issued (3)Signed Off (1)Inspection (10)Special Inspection (30)
10/01/2026
Permit issued — Plumbing
B01104960-S1-PL
05/05/2026
Special inspection requirement — HVAC-R and service water heating equipment
Tianchen Hu
05/05/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
Tianchen Hu
05/05/2026
Special inspection requirement — HVAC-R and service water heating system controls
Tianchen Hu
05/05/2026
Special inspection requirement — Energy Code Compliance Inspections
Tianchen Hu
05/05/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Tianchen Hu
05/04/2026
Filed — Alteration
PROPOSED RENOVATION FOR A FOOD SERVICE AND INSTALLATION OF KITCHEN HOOD EXHAUST SYSTEM, AND WALK-IN COOLER & FREEZER AT FIRST FLOOR. NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
B01104960-P5
04/21/2026
Special inspection requirement — HVAC-R and service water heating system controls
Tianchen Hu
04/21/2026
Special inspection requirement — HVAC-R and service water heating equipment
Tianchen Hu
04/21/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
Tianchen Hu
04/21/2026
Special inspection requirement — Energy Code Compliance Inspections
Tianchen Hu
04/21/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Tianchen Hu
03/13/2026
Filed — Alteration
PROPOSED RENOVATION FOR A FOOD SERVICE AND INSTALLATION OF KITCHEN HOOD EXHAUST SYSTEM, AND WALK-IN COOLER & FREEZER AT FIRST FLOOR. NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
B01104960-P4
01/28/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Tianchen Hu
03/11/2025
Signed off — Alteration
PROPOSED RENOVATION FOR A FOOD SERVICE AND INSTALLATION OF KITCHEN HOOD EXHAUST SYSTEM, AND WALK-IN COOLER & FREEZER AT FIRST FLOOR. NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
B01104960-I1
03/06/2025
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
03/03/2025
Special inspection requirement — Mechanical Systems
Tianchen Hu
03/03/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Tianchen Hu
03/03/2025
Special inspection requirement — Energy Code Compliance Inspections
Tianchen Hu
03/03/2025
Special inspection requirement — Fire-Resistance Rated Construction
Tianchen Hu
03/03/2025
Special inspection requirement — Final
Tianchen Hu
03/03/2025
Special inspection requirement — Interior lighting power
Tianchen Hu
03/03/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
Tianchen Hu
03/03/2025
Special inspection requirement — HVAC-R and service water heating equipment
Tianchen Hu
03/03/2025
Special inspection requirement — HVAC-R and service water heating system controls
Tianchen Hu
03/03/2025
Special inspection requirement — Lighting controls
Tianchen Hu
02/27/2025
Filed — Alteration
PROPOSED RENOVATION FOR A FOOD SERVICE AND INSTALLATION OF KITCHEN HOOD EXHAUST SYSTEM, AND WALK-IN COOLER & FREEZER AT FIRST FLOOR. NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
B01104960-P3
02/21/2025
Inspection — Fail-Final General Construction Non-Directive 14
Fail
View inspection ↗
02/07/2025
Filed — Alteration
PROPOSED RENOVATION FOR A FOOD SERVICE AND INSTALLATION OF KITCHEN HOOD EXHAUST SYSTEM, AND WALK-IN COOLER & FREEZER AT FIRST FLOOR. NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
B01104960-P2
02/05/2025
Special inspection requirement — HVAC-R and service water heating system controls
Tianchen Hu
02/05/2025
Special inspection requirement — Lighting controls
Tianchen Hu
02/05/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
Tianchen Hu
02/05/2025
Special inspection requirement — Interior lighting power
Tianchen Hu
02/05/2025
Special inspection requirement — HVAC-R and service water heating equipment
Tianchen Hu
02/05/2025
Special inspection requirement — Fire-Resistance Rated Construction
Tianchen Hu
02/05/2025
Special inspection requirement — Final
Tianchen Hu
02/05/2025
Special inspection requirement — Energy Code Compliance Inspections
Tianchen Hu
02/05/2025
Special inspection requirement — Mechanical Systems
Tianchen Hu
01/31/2025
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
12/24/2024
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
12/24/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
12/24/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
11/14/2024
Filed — Alteration
PROPOSED RENOVATION FOR A FOOD SERVICE AND INSTALLATION OF KITCHEN HOOD EXHAUST SYSTEM, AND WALK-IN COOLER & FREEZER AT FIRST FLOOR. NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
B01104960-P1
09/23/2024
Permit issued — Plumbing
B01104960-S1-PL
09/18/2024
Permit issued — Mechanical Systems
B01104960-I1-GC-CX
09/11/2024
Filed — Alteration
PROPOSED RENOVATION FOR A FOOD SERVICE AND INSTALLATION OF KITCHEN HOOD EXHAUST SYSTEM, AND WALK-IN COOLER & FREEZER AT FIRST FLOOR. NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
B01104960-I1
09/11/2024
Filed — Alteration
PROPOSED RENOVATION FOR A FOOD SERVICE AND INSTALLATION OF KITCHEN HOOD EXHAUST SYSTEM, AND WALK-IN COOLER & FREEZER AT FIRST FLOOR. NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
B01104960-S1
10/26/2023
Inspection — Pass-Final PL - Up to 9 Requested Floors
Pass
View inspection ↗
06/15/2023
Inspection — Pass-Final PL - Up to 9 Requested Floors
Pass
View inspection ↗
04/04/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
08/24/2022
Inspection — Pass-Final PL - Underground
Pass
View inspection ↗
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedXH&RC PLBG AND HTG INC10/01/2026
DOB NOWPlumbingPermit IssuedXH&RC PLBG AND HTG INC09/23/2024
DOB NOWMechanical SystemsSigned-offKLE CONSTRUCTION INC09/18/2024
BISEQISSUEDARSENAL SCAFFOLD INC08/20/2010
1 project · most recent 05/04/2026
Refrigeration Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
05/04/2026Signed-offKLE CONSTRUCTION INCRefrigeration Systems, Ventilation Systems
Ventilation
Floaire DU180H 3,920 CFM · Kitchen Exhaust ×3
N/A N/A 3,920 CFM · Kitchen Exhaust ×3
Refrigeration
Norlake KLF88-C 4,400 BTU · Refrigeration Unit ×3
1 project · most recent 05/04/2026
Gas Water/Sanitary
FiledStatusContractorScope
05/04/2026Permit IssuedXH&RC PLBG AND HTG INCGas, Water/Sanitary
1 project · most recent 04/07/2025
FiledStatusContractorScope
04/07/2025CompleteUNITED ELEC'L CONT'G CORP1 meters, 1 new_meters
▾Field Inspections (DOB CAP) — 10
DateTypeResultReport
03/06/2025Pass-Final General Construction Non-Directive 14PassView ↗
02/21/2025Fail-Final General Construction Non-Directive 14FailView ↗
01/31/2025Pass-Final PL - Up to 3 Requested FloorsPassView ↗
12/24/2024Certified Gas-Gas-Piping-RoughingCertifiedView ↗
12/24/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
12/24/2024Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
10/26/2023Pass-Final PL - Up to 9 Requested FloorsPassView ↗
06/15/2023Pass-Final PL - Up to 9 Requested FloorsPassView ↗
04/04/2023Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
08/24/2022Pass-Final PL - UndergroundPassView ↗
▾Special Inspection Requirements (DOB NOW) — 31
DateRequirementInspectorRole
05/05/2026HVAC-R and service water heating equipmentTianchen Huenergy_progress
05/05/2026HVAC-R and service water piping design and insulationTianchen Huenergy_progress
05/05/2026HVAC-R and service water heating system controlsTianchen Huenergy_progress
05/05/2026Energy Code Compliance InspectionsTianchen Huprogress
05/05/2026Fire-Resistant Penetrations and JointsTianchen Huspecial
04/21/2026HVAC-R and service water heating system controlsTianchen Huenergy_progress
04/21/2026HVAC-R and service water heating equipmentTianchen Huenergy_progress
04/21/2026HVAC-R and service water piping design and insulationTianchen Huenergy_progress
04/21/2026Energy Code Compliance InspectionsTianchen Huprogress
04/21/2026Fire-Resistant Penetrations and JointsTianchen Huspecial
01/28/2026Fire-Resistant Penetrations and JointsTianchen Huspecial
03/03/2025Mechanical SystemsTianchen Huspecial
03/03/2025Fire-Resistant Penetrations and JointsTianchen Huspecial
03/03/2025Energy Code Compliance InspectionsTianchen Huprogress
03/03/2025Fire-Resistance Rated ConstructionTianchen Huprogress
03/03/2025FinalTianchen Huprogress
03/03/2025Interior lighting powerTianchen Huenergy_progress
03/03/2025HVAC-R and service water piping design and insulationTianchen Huenergy_progress
03/03/2025HVAC-R and service water heating equipmentTianchen Huenergy_progress
03/03/2025HVAC-R and service water heating system controlsTianchen Huenergy_progress
03/03/2025Lighting controlsTianchen Huenergy_progress
02/05/2025HVAC-R and service water heating system controlsTianchen Huenergy_progress
02/05/2025Lighting controlsTianchen Huenergy_progress
02/05/2025HVAC-R and service water piping design and insulationTianchen Huenergy_progress
02/05/2025Interior lighting powerTianchen Huenergy_progress
Latest 25 of 31.
▾Documents — 52 on file (BIS + DOB NOW)
▸Plans & Drawings7
▸DOB NOWPlans/Sketch7
08/17/2026B01104960-P4Request digital key ↗
08/17/2026B01104960-P5Request digital key ↗
08/17/2026B01104960-P2Request digital key ↗
Showing 3 of 7 on file for this type
▸Applications & Permits2
▸BISPLAN / WORK APPROVAL APPLICATION1
09/02/2010320205791Open ↗
▸BISWORK PERMIT APPLICATION1
09/02/2010320205791Open ↗
▸Seals & Professional Certifications33
▸DOB NOWProgress Inspector Seal & Signature16
09/30/2026B01104960-S1Open ↗
09/30/2026B01104960-S1Open ↗
09/30/2026B01104960-S1Open ↗
Showing 3 of 16 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature7
08/17/2026B01104960-P1Open ↗
08/17/2026B01104960-P5Open ↗
08/17/2026B01104960-I1Open ↗
Showing 3 of 7 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature7
09/30/2026B01104960-S1Open ↗
09/01/2026B01104960-I1Open ↗
09/01/2026B01104960-I1Open ↗
Showing 3 of 7 on file for this type
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
09/02/2010320205791Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM1
09/02/2010320205791Open ↗
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION1
09/02/2010320205791Open ↗
▸Environmental & Asbestos8
▸DOB NOWDEP ACP-5: Asbestos Assessment Report7
08/17/2026B01104960-P2Open ↗
08/17/2026B01104960-S1Open ↗
08/17/2026B01104960-P5Open ↗
Showing 3 of 7 on file for this type
▸BISASBESTOS EXEMPTION CERTIFICATION LETTER1
09/02/2010320205791Open ↗
▸Approvals, Objections & Sign-offs1
▸BISADMINISTRATIVE OBJECTIONS1
09/02/2010320205791Open ↗
▸Filing & Intake Forms1
▸BISEFILING COVER SHEET1
09/02/2010320205791Open ↗