← Back
Walk-up apt, over six families with stores
1584 YORK AVENUE
MANHATTAN · Upper East Side-Yorkville · BIN 1051181
💬 Discuss this project
1910Year Built
5Stories
C7Building Class
R10Zoning
8,788 sfGross Floor Area
9Units
Rent Stabilized26 Open Violations ▸
Walk-up apt, over six families with stores · Owner of record: CALYPHIL REALTY CORP · 2,548 sf lot · 3.45 FAR built · Flood zone X
Locations of Work
ArchitectureMechanicalPlumbingGeneral
Permit Issued — active, not yet Signed-off
RoofUnder Construction1p · 1 filing · 20 docs
Floor 1Under Construction15p · 1 filing · 20 docs
CellarUnder Construction10p · 1 filing · 20 docs
Filed — no permit issued7p · 1 filing · 1 doc
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
CALYPHIL REALTY803/22/2026
CALLYPHIL REALTY603/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
IKRA CONSULTING LLC207/16/2026
XC ENGINEERING PC205/26/2026
LEDER-LUIS ARCHITECTURAL DESIGN, PL110/18/2023
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
MCSS REST203/21/2026
MUNICIPAL BUILDING CONSULTANTS103/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
IIEMAR LLCGeneral Contractor208/01/2026
VALDINEI LOPESElectrical103/21/2026
SMART PLBG & HTG CORPPlumbing106/27/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
IKRA CONSULTING LLC7032407/16/2026
Building Lifecycle
All (85)Filed (5)Permit Issued (3)Violation (54)Inspection (6)Objection (2)Special Inspection (15)
08/19/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
08/19/2026
Inspection — Fail-Final General Construction Non-Directive 14
Fail
View inspection ↗
08/05/2026
Inspection — Certified Sprinkler-SP-Fixtures-Finish
Certified
View inspection ↗
07/31/2026
Permit issued — Mechanical Systems
M01323989-S5-MS
07/31/2026
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
07/16/2026
Filed — Alteration
Installation of plumbing fixtures as per plans filed herewith, No change to use, egress or occupancy
M01323989-S5
07/15/2026
Special inspection requirement — Tenant Protection Plan Compliance
MD MOSTAFA
07/06/2026
Special inspection requirement — Mechanical Systems
MD MOSTAFA
07/06/2026
Special inspection requirement — Final
MD MOSTAFA
06/30/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
06/30/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
06/25/2026
Permit issued — Plumbing
M01323989-S4-PL
06/09/2026
Filed — Alteration
Installation of plumbing fixtures as per plans filed herewith, No change to use, egress or occupancy
M01323989-S4
06/08/2026
Special inspection requirement — Tenant Protection Plan Compliance
MD MOSTAFA
05/31/2026
Special inspection requirement — Lighting controls
MD MOSTAFA
05/31/2026
Special inspection requirement — Interior lighting power
MD MOSTAFA
05/31/2026
Special inspection requirement — Maintenance information
MD MOSTAFA
05/31/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
MD MOSTAFA
05/31/2026
Special inspection requirement — Tenant Protection Plan Compliance
05/26/2026
Filed — Alteration
Installation of plumbing fixtures as per plans filed herewith, No change to use, egress or occupancy
M01323989-P1
02/09/2026
Permit issued — General Construction
M01323989-I1-GC
01/21/2026
Objection resolved — Addressed
11/28/2025
Objection raised — Scope
11/26/2025
Filed — Alteration
Installation of plumbing fixtures as per plans filed herewith, No change to use, egress or occupancy
M01323989-I1
11/14/2025
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
06/04/2025
Violation issued (HPD, closed)
A
11/22/2024
Violation issued (HPD, closed)
I
09/23/2024
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
04/02/2024
Violation issued (HPD, closed)
A
01/04/2024
Special inspection requirement — Interior lighting power
01/04/2024
Special inspection requirement — Maintenance information
12/27/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
11/03/2023
Special inspection requirement — Fire-Resistance Rated Construction
11/03/2023
Special inspection requirement — Lighting controls
10/18/2023
Filed — Alteration CO
M00930660-I1
09/22/2023
Special inspection requirement — Tenant Protection Plan Compliance
06/30/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
06/30/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
06/20/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
06/20/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
04/30/2023
Violation issued (HPD, open)
B
04/30/2023
Violation issued (HPD, open)
B
04/30/2023
Violation issued (HPD, open)
B
04/30/2023
Violation issued (HPD, open)
C
04/30/2023
Violation issued (HPD, closed)
B
04/25/2023
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/16/2022
Violation issued (HPD, closed)
A
10/11/2017
Violation issued (HPD, closed)
B
07/06/2017
Violation issued (HPD, closed)
B
01/13/2017
Violation issued (HPD, closed)
A
11/12/2015
Violation issued (HPD, closed)
B
11/12/2015
Violation issued (HPD, closed)
B
10/01/2015
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/26/2015
Violation issued (HPD, closed)
A
03/16/2015
Violation issued (HPD, closed)
A
10/20/2009
Violation issued (HPD, closed)
B
10/20/2009
Violation issued (HPD, closed)
B
10/20/2009
Violation issued (HPD, closed)
B
10/20/2009
Violation issued (HPD, open)
B
12/09/2007
Violation issued (HPD, closed)
A
Latest 60 of 85 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsPermit IssuedIIEMAR LLC07/31/2026
DOB NOWPlumbingPermit IssuedSMART PLBG & HTG CORP06/25/2026
DOB NOWGeneral ConstructionPermit IssuedIIEMAR LLC02/09/2026
BISPLISSUEDAMERICAN STANDARD P&H CORORP.05/20/2014
BISFBISSUEDAMERICAN STANDARD P&H CORORP.05/20/2014
BISPLISSUEDB H PLBG & HTG CORP05/01/2007
BISPLISSUEDB H PLBG & HTG CORP06/02/2004
BISOTISSUEDDA HAI CONSTRUCTION INC05/13/2004
BISOTISSUEDADR CONSTR CORP INC10/02/1997
BISOTISSUEDLARRY BENTON09/04/1997
BISOTISSUEDARCH CONSTRUCTION CO. INC.07/26/1993
BIS—ISSUEDYEAR ROUND REFRIGERATION08/21/1990
1 project · most recent 07/16/2026
Heating and Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
07/16/2026Permit IssuedIIEMAR LLCHeating and Air Conditioning Systems
Heat / Cool
Mitsubishi Electric MXZ-SM60NAM2 66,000 BTU · Condensing Unit ×2
PEFY-P18NMAU-E4 20,000 BTU · Vrf Indoor ×2
PEFY-P36NMHU-E2 40,000 BTU · Vrf Indoor ×2
1 project · most recent 07/16/2026
FiledStatusContractorScope
07/16/2026———
1 project · most recent 07/16/2026
Water/Sanitary
FiledStatusContractorScope
07/16/2026Permit IssuedSMART PLBG & HTG CORPWater/Sanitary
4 projects · most recent 03/10/2026
General Wiring
FiledStatusContractorScope
03/10/2026Permit IssuedGMJ ELECTRIC CORPGeneral Wiring
08/05/2021CompleteGREEN APPLE ELECL SVCS LL—
07/15/2021Permit IssuedTEMPEST ELEC'L CONTRG, IN—
09/15/2019CompleteTEMPEST ELEC'L CONTRG, IN10 meters, 9 new_meters
▾Field Inspections (DOB CAP) — 6
DateTypeResultReport
08/19/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
08/19/2026Fail-Final General Construction Non-Directive 14FailView ↗
08/05/2026Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
07/31/2026Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
06/30/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
06/30/2026Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 15
DateRequirementInspectorRole
07/15/2026Tenant Protection Plan ComplianceMD MOSTAFAspecial
07/06/2026Mechanical SystemsMD MOSTAFAspecial
07/06/2026FinalMD MOSTAFAprogress
06/08/2026Tenant Protection Plan ComplianceMD MOSTAFAspecial
05/31/2026Lighting controlsMD MOSTAFAenergy_progress
05/31/2026Interior lighting powerMD MOSTAFAenergy_progress
05/31/2026Maintenance informationMD MOSTAFAenergy_progress
05/31/2026Fire-Resistant Penetrations and JointsMD MOSTAFAspecial
05/31/2026Tenant Protection Plan Compliance—special
01/04/2024Interior lighting power—energy_progress
01/04/2024Maintenance information—energy_progress
12/27/2023Fire-Resistant Penetrations and Joints—special
11/03/2023Fire-Resistance Rated Construction—progress
11/03/2023Lighting controls—energy_progress
09/22/2023Tenant Protection Plan Compliance—special
▾Documents — 53 on file (BIS + DOB NOW)
▸Plans & Drawings6
▸DOB NOWPlans/Sketch6
08/17/2026M01323989-S4Request digital key ↗
08/17/2026M01323989-I1Request digital key ↗
08/17/2026M01323989-S5Request digital key ↗
Showing 3 of 6 on file for this type
▸Applications & Permits6
▸BISWORK PERMIT APPLICATION3
05/20/2014140093002Open ↗
05/20/2014140093002Open ↗
11/06/2008110367656Open ↗
▸BISPLAN / WORK APPROVAL APPLICATION2
07/02/2013140093002Open ↗
10/25/2008110367656Open ↗
▸BISPLACE OF ASSEMBLY1
08/29/2008110240052Open ↗
▸Seals & Professional Certifications19
▸DOB NOWDPL-1: Design Professional Seal & Signature4
08/17/2026M01323989-S4Open ↗
08/17/2026M01323989-I1Open ↗
08/17/2026M01323989-S5Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWProgress Inspector Seal & Signature4
08/29/2026M01323989-I1Open ↗
08/29/2026M01323989-I1Open ↗
08/29/2026M01323989-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature4
08/29/2026M01323989-I1Open ↗
08/25/2026M01323989-S4Open ↗
08/25/2026M01323989-S5Open ↗
Showing 3 of 4 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION2
10/25/2008110367656Open ↗
08/29/2008110240052Open ↗
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION1
07/02/2013140093002Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
07/02/2013140093002Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
10/25/2008110367656Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
07/02/2013140093002Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM1
10/25/2008110367656Open ↗
▸Trade Schedules & Equipment3
▸BISSCHEDULE B - PLUMBING1
07/02/2013140093002Open ↗
▸BISSCHEDULE C - HEATING & COMBUSTION EQUIPMENT1
07/02/2013140093002Open ↗
▸BISSELF-CERT PLUMBING NOTICE1
08/26/2014140093002Open ↗
▸Safety & Tenant Protection2
▸BISST-1: Street Tree Checklist1
10/25/2008110367656Open ↗
▸DOB NOWStreet Tree Checklist1
08/13/2026M00930660-I1Open ↗
▸Environmental & Asbestos8
▸DOB NOWDEP ACP-5: Asbestos Assessment Report6
08/17/2026M01323989-S4Open ↗
08/17/2026M01323989-I1Open ↗
08/17/2026M01323989-S5Open ↗
Showing 3 of 6 on file for this type
▸BISASBESTOS EXEMPTION CERTIFICATION LETTER1
10/25/2008110367656Open ↗
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
07/02/2013140093002Open ↗
▸Energy Compliance2
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY1
07/02/2013140093002Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY FOR ENERGY CODE PROGRESS INSPECTIONS1
07/02/2013140093002Open ↗
▸Inspections & Test Reports1
▸BISTECHNICAL REPORT: RESPONSIBILITY1
07/02/2013140093002Open ↗
▸Approvals, Objections & Sign-offs2
▸BISADMINISTRATIVE OBJECTIONS2
10/25/2008110367656Open ↗
08/29/2008110240052Open ↗
▸Cost, Insurance & Ownership2
▸BISCOST AFFIDAVIT2
07/02/2013140093002Open ↗
10/25/2008110367656Open ↗
▸Filing & Intake Forms2
▸BISeFiling Job Application Cover Sheet2
10/25/2008110367656Open ↗
07/02/2013140093002Open ↗