← Back
Elevator apt, fireproof without stores
159 ALASKA STREET
STATEN ISLAND · West New Brighton-Silver Lake-Grymes Hill · BIN 5095821
💬 Discuss this project
1962Year Built
8Stories
D3Building Class
R3-2Zoning
550,010 sfGross Floor Area
634Units
Rent Stabilized240 Open Violations 230 unresolved · 10 paperwork only ▸FDNY Report ↗
Elevator apt, fireproof without stores · Owner of record: NYC HOUSING AUTHORITY · 550,992 sf lot · 1 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbing
Permit Issued — active, not yet Signed-off
RoofUnder Construction45p · 2 filings · 20 docs
Floor 1Under Construction61p · 2 filings · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
PLATINUM SERVICES NY407/08/2026
AJS CONSTRUCTON CORP103/21/2026
N.Y.C HOUSING AUTHORITY103/21/2026
NEW YORK CITY HOUSING AUTHORITY203/21/2026
NYCHA103/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
EP ENGINEERING LLC408/21/2026
WARE MALCOMB406/01/2026
OCV ARCHITECTS204/15/2026
ALWAYS FAST SERVICES CORP101/08/2026
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
JM ZONING, LLC.1203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
WEST BRIGHTON BUILDER LLCGeneral Contractor307/08/2026
JAMAL DUDLEYElectrical103/21/2026
STEPHENS, KENNETHElectrical103/21/2026
AIRCRAFT AIR COND CORPGeneral Contractor107/08/2026
PLATINUM SERVICES NY LLCGeneral Contractor107/08/2026
DUAL FUEL PLUBING & HTINGPlumbing106/07/2026
DUDLEY JAMALElectrical103/21/2026
M. EARLY PLBG & HTG CORPPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
SPECIAL TESTING & CONSULT1688708/21/2026
Building Lifecycle
All (64)Filed (11)Permit Issued (7)Violation (4)Inspection (8)Objection (4)Special Inspection (30)
08/31/2026
Inspection — Pass-Final PL - Up to 9 Requested Floors
Pass
View inspection ↗
08/21/2026
Filed — Alteration
FOUNDATION DESIGN & RENOVATION FOR ONE STORY COMMUNITY FACILITY
S01132863-P5
08/21/2026
Special inspection requirement — Exhaust and Vent Systems in Plenums and Ducts
SEBASTIAN SETTEDUCATE JR., P.E
08/21/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
SEBASTIAN SETTEDUCATE JR., P.E
08/21/2026
Special inspection requirement — Mechanical Systems
SEBASTIAN SETTEDUCATE JR., P.E
08/21/2026
Special inspection requirement — Energy Code Compliance Inspections
SEBASTIAN SETTEDUCATE JR., P.E
08/21/2026
Special inspection requirement — Final
SEBASTIAN SETTEDUCATE JR., P.E
08/21/2026
Special inspection requirement — Duct leakage testing, insulation and design
SEBASTIAN SETTEDUCATE JR., P.E
08/21/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
SEBASTIAN SETTEDUCATE JR., P.E
08/21/2026
Special inspection requirement — HVAC-R and service water heating equipment
SEBASTIAN SETTEDUCATE JR., P.E
08/21/2026
Special inspection requirement — HVAC-R and service water heating system controls
SEBASTIAN SETTEDUCATE JR., P.E
08/21/2026
Special inspection requirement — Maintenance information
SEBASTIAN SETTEDUCATE JR., P.E
08/05/2026
Inspection — Pass-Final PL - Up to 9 Requested Floors
Pass
View inspection ↗
06/22/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
06/03/2026
Permit issued — Structural
S01132863-S7-ST
06/02/2026
Special inspection requirement — Final
SEBASTIAN SETTEDUCATE JR., P.E
06/02/2026
Special inspection requirement — Concrete - Cast-In-Place
SEBASTIAN SETTEDUCATE JR., P.E
06/02/2026
Special inspection requirement — Structural Steel - High Strength Bolting
SEBASTIAN SETTEDUCATE JR., P.E
06/02/2026
Special inspection requirement — Structural Steel - Details
SEBASTIAN SETTEDUCATE JR., P.E
06/02/2026
Special inspection requirement — Structural Steel - Welding
SEBASTIAN SETTEDUCATE JR., P.E
06/02/2026
Special inspection requirement — Masonry
SEBASTIAN SETTEDUCATE JR., P.E
06/02/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
SEBASTIAN SETTEDUCATE JR., P.E
06/02/2026
Special inspection requirement — Structural Cold-Formed Steel
SEBASTIAN SETTEDUCATE JR., P.E
06/01/2026
Filed — Alteration
FOUNDATION DESIGN & RENOVATION FOR ONE STORY COMMUNITY FACILITY
S01132863-P4
05/07/2026
Violation issued (HPD, open)
A
04/24/2026
Special inspection requirement — Concrete - Cast-In-Place
SEBASTIAN SETTEDUCATE JR., P.E
04/24/2026
Special inspection requirement — Masonry
SEBASTIAN SETTEDUCATE JR., P.E
04/24/2026
Special inspection requirement — Structural Cold-Formed Steel
SEBASTIAN SETTEDUCATE JR., P.E
04/24/2026
Special inspection requirement — Final
SEBASTIAN SETTEDUCATE JR., P.E
04/24/2026
Special inspection requirement — Structural Steel - Welding
SEBASTIAN SETTEDUCATE JR., P.E
04/24/2026
Special inspection requirement — Structural Steel - High Strength Bolting
SEBASTIAN SETTEDUCATE JR., P.E
04/24/2026
Special inspection requirement — Structural Steel - Details
SEBASTIAN SETTEDUCATE JR., P.E
04/24/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
SEBASTIAN SETTEDUCATE JR., P.E
04/22/2026
Permit issued — Foundation
S01132863-S5-FO
04/15/2026
Filed — Alteration
FOUNDATION DESIGN & RENOVATION FOR ONE STORY COMMUNITY FACILITY
S01132863-S7
04/15/2026
Filed — Alteration
FOUNDATION DESIGN & RENOVATION FOR ONE STORY COMMUNITY FACILITY
S01132863-S5
04/13/2026
Permit issued — Mechanical Systems
S01132863-S1-MS
03/24/2026
Special inspection requirement — Footing and Foundation
SEBASTIAN SETTEDUCATE JR., P.E
03/24/2026
Special inspection requirement — Final
SEBASTIAN SETTEDUCATE JR., P.E
03/24/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
SEBASTIAN SETTEDUCATE JR., P.E
03/24/2026
Special inspection requirement — Post-installed Anchors
SEBASTIAN SETTEDUCATE JR., P.E
03/11/2026
Permit issued — General Construction
S01145357-I1-GC
03/11/2026
Permit issued — Plumbing
S01132863-S2-PL
02/11/2026
Filed — Alteration
FOUNDATION DESIGN & RENOVATION FOR ONE STORY COMMUNITY FACILITY
S01132863-S2
02/10/2026
Filed — Alteration
FOUNDATION DESIGN & RENOVATION FOR ONE STORY COMMUNITY FACILITY
S01132863-P3
01/26/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
01/15/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
01/08/2026
Filed — Alteration
S01343720-I1
01/08/2026
Permit issued — Construction Fence
S01343720-I1-FN
01/07/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
12/01/2025
Filed — Alteration
FOUNDATION DESIGN & RENOVATION FOR ONE STORY COMMUNITY FACILITY
S01132863-P2
11/24/2025
Violation issued (HPD, open)
I
11/07/2025
Inspection — Certified Gas-Gas-Piping-Underground
Certified
View inspection ↗
09/18/2025
Permit issued — Plumbing
S01132863-I1-PL
09/11/2025
Objection resolved — Addressed
09/10/2025
Objection raised — Admin
08/28/2025
Filed — Alteration
FOUNDATION DESIGN & RENOVATION FOR ONE STORY COMMUNITY FACILITY
S01132863-S1
06/12/2025
Violation issued (HPD, open)
A
05/03/2025
Inspection — Pass-Final PL - Up to 9 Requested Floors
Pass
View inspection ↗
02/26/2025
Objection resolved — Addressed
Latest 60 of 64 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWStructuralPermit IssuedWEST BRIGHTON BUILDER LLC06/03/2026
DOB NOWFoundationPermit IssuedWEST BRIGHTON BUILDER LLC04/22/2026
DOB NOWMechanical SystemsPermit IssuedAIRCRAFT AIR COND CORP04/13/2026
DOB NOWGeneral ConstructionPermit IssuedWEST BRIGHTON BUILDER LLC03/11/2026
DOB NOWPlumbingPermit IssuedM. EARLY PLBG & HTG CORP03/11/2026
DOB NOWConstruction FencePermit IssuedPLATINUM SERVICES NY LLC01/08/2026
DOB NOWPlumbingPermit IssuedDUAL FUEL PLUBING & HTING09/18/2025
BISPLISSUEDACCURATE PLBG & HTG CORP11/23/2011
BISOTISSUEDA.J.S. PROJECT MGMT INC11/18/2011
BISOTISSUEDCANEA MARE CONTRACTING CORP03/07/2000
BISPLISSUEDCANEA MARE CONTRACTING CORP03/07/2000
1 project · most recent 08/21/2026
Heating and Air Conditioning Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
08/21/2026Permit IssuedWEST BRIGHTON BUILDER LLCHeating and Air Conditioning Systems, Ventilation Systems
Heat / Cool
Mitsubishi Electric PUHY-EP120TNU-A1 120,000 BTU · Vrf Outdoor ×2
PUHY-EP168TNU-A1 168,000 BTU · Vrf Outdoor ×2
PUHY-EP192TNU-A1 192,000 BTU · Vrf Outdoor ×2
Ventilation
Greenheck CSP-A1050-VG 825 CFM · Exhaust Fan ×2
CSP-A390-VG 300 CFM · Exhaust Fan ×2
SP-A710-VG 400 CFM · Exhaust Fan ×2
Mitsubishi Electric LGH-F940RVX2-E 910 CFM · Erv ×2
1 project · most recent 08/21/2026
Gas Water/Sanitary
FiledStatusContractorScope
08/21/2026Permit IssuedM. EARLY PLBG & HTG CORPGas, Water/Sanitary
1 project · most recent 06/22/2026
General Wiring
FiledStatusContractorScope
06/22/2026Permit IssuedTRITECH ELECTRICAL & DATA INCGeneral Wiring
1 project · most recent 08/21/2026
Steel Concrete
FiledStatusContractorScope
08/21/2026Permit IssuedWEST BRIGHTON BUILDER LLCSteel, Concrete
▾Field Inspections (DOB CAP) — 8
DateTypeResultReport
08/31/2026Pass-Final PL - Up to 9 Requested FloorsPassView ↗
08/05/2026Pass-Final PL - Up to 9 Requested FloorsPassView ↗
06/22/2026Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
01/26/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
01/15/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
01/07/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
11/07/2025Certified Gas-Gas-Piping-UndergroundCertifiedView ↗
05/03/2025Pass-Final PL - Up to 9 Requested FloorsPassView ↗
▾Special Inspection Requirements (DOB NOW) — 56
DateRequirementInspectorRole
08/21/2026Exhaust and Vent Systems in Plenums and DuctsSEBASTIAN SETTEDUCATE JR., P.Especial
08/21/2026Fire-Resistant Penetrations and JointsSEBASTIAN SETTEDUCATE JR., P.Especial
08/21/2026Mechanical SystemsSEBASTIAN SETTEDUCATE JR., P.Especial
08/21/2026Energy Code Compliance InspectionsSEBASTIAN SETTEDUCATE JR., P.Eprogress
08/21/2026FinalSEBASTIAN SETTEDUCATE JR., P.Eprogress
08/21/2026Duct leakage testing, insulation and designSEBASTIAN SETTEDUCATE JR., P.Eenergy_progress
08/21/2026HVAC-R and service water piping design and insulationSEBASTIAN SETTEDUCATE JR., P.Eenergy_progress
08/21/2026HVAC-R and service water heating equipmentSEBASTIAN SETTEDUCATE JR., P.Eenergy_progress
08/21/2026HVAC-R and service water heating system controlsSEBASTIAN SETTEDUCATE JR., P.Eenergy_progress
08/21/2026Maintenance informationSEBASTIAN SETTEDUCATE JR., P.Eenergy_progress
06/02/2026FinalSEBASTIAN SETTEDUCATE JR., P.Eprogress
06/02/2026Concrete - Cast-In-PlaceSEBASTIAN SETTEDUCATE JR., P.Especial
06/02/2026Structural Steel - High Strength BoltingSEBASTIAN SETTEDUCATE JR., P.Especial
06/02/2026Structural Steel - DetailsSEBASTIAN SETTEDUCATE JR., P.Especial
06/02/2026Structural Steel - WeldingSEBASTIAN SETTEDUCATE JR., P.Especial
06/02/2026MasonrySEBASTIAN SETTEDUCATE JR., P.Especial
06/02/2026Structural Stability – Alterations of existing buildingsSEBASTIAN SETTEDUCATE JR., P.Especial
06/02/2026Structural Cold-Formed SteelSEBASTIAN SETTEDUCATE JR., P.Especial
04/24/2026Concrete - Cast-In-PlaceSEBASTIAN SETTEDUCATE JR., P.Especial
04/24/2026MasonrySEBASTIAN SETTEDUCATE JR., P.Especial
04/24/2026Structural Cold-Formed SteelSEBASTIAN SETTEDUCATE JR., P.Especial
04/24/2026FinalSEBASTIAN SETTEDUCATE JR., P.Eprogress
04/24/2026Structural Steel - WeldingSEBASTIAN SETTEDUCATE JR., P.Especial
04/24/2026Structural Steel - High Strength BoltingSEBASTIAN SETTEDUCATE JR., P.Especial
04/24/2026Structural Steel - DetailsSEBASTIAN SETTEDUCATE JR., P.Especial
Latest 25 of 56.
▾Documents — 62 on file (BIS + DOB NOW)
▸Plans & Drawings10
▸DOB NOWPlans/Sketch10
08/20/2026S01145357-I1Request digital key ↗
08/17/2026S01343720-I1Request digital key ↗
08/16/2026S01132863-S1Request digital key ↗
Showing 3 of 10 on file for this type
▸Applications & Permits3
▸BISWORK PERMIT APPLICATION2
11/25/2011520017115Open ↗
11/19/2011520017115Open ↗
▸BISPLAN / WORK APPROVAL APPLICATION1
11/24/2009520017115Open ↗
▸Seals & Professional Certifications25
▸DOB NOWDPL-1: Design Professional Seal & Signature10
08/20/2026S01145357-I1Open ↗
08/17/2026S01343720-I1Open ↗
08/16/2026S01132863-S1Open ↗
Showing 3 of 10 on file for this type
▸DOB NOWProgress Inspector Seal & Signature8
09/23/2026S01132863-P5Open ↗
09/23/2026S01132863-P5Open ↗
09/16/2026S01132863-S7Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature6
09/23/2026S01132863-P5Open ↗
09/16/2026S01132863-S7Open ↗
09/01/2026S01132863-S1Open ↗
Showing 3 of 6 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION1
10/26/2009520017115Open ↗
▸Trade Schedules & Equipment1
▸BISSCHEDULE B - PLUMBING1
10/23/2009520017115Open ↗
▸Safety & Tenant Protection1
▸DOB NOWStreet Tree Checklist1
08/13/2026S01145357-I1Open ↗
▸Environmental & Asbestos6
▸DOB NOWDEP ACP-20/ACP-21: Asbestos Project Conditional Completion Form/Asbestos Project Completion Form5
08/20/2026S01145357-I1Open ↗
08/16/2026S01132863-S1Open ↗
08/16/2026S01132863-S5Open ↗
Showing 3 of 5 on file for this type
▸BISDEP ASBESTOS PROJECT COMPLETION FORM1
11/19/2011520017115Open ↗
▸Approvals, Objections & Sign-offs13
▸DOB NOWFee Exempt Supporting Document - DOF ACRIS report or BIB letter10
08/17/2026S01343720-I1Open ↗
08/16/2026S01132863-S2Open ↗
08/16/2026S01132863-S1Open ↗
Showing 3 of 10 on file for this type
▸BISLETTERS - SUPPORTING DOCUMENTATION2
11/25/2009520017115Open ↗
11/25/2009520017115Open ↗
▸BISADMINISTRATIVE OBJECTIONS1
10/23/2009520017115Open ↗
▸Cost, Insurance & Ownership1
▸BISCOST AFFIDAVIT1
10/23/2009520017115Open ↗
▸Filing & Intake Forms1
▸BISEFILING COVER SHEET1
10/23/2009520017115Open ↗
▸Other Documents1
▸DOB NOWProof of Historic Building1
08/13/2026S01145357-I1Open ↗