← Back
Two family frame
159 MILTON AVENUE
STATEN ISLAND · New Dorp-Midland Beach · BIN 5056094
💬 Discuss this project
1960Year Built
2Stories
B2Building Class
R3-1Zoning
1,800 sfGross Floor Area
2Units
Two family frame · 6,200 sf lot · 0.29 FAR built · Flood zone AE
Locations of Work
ArchitectureElectrical
Roof2p · 1 filing · 10 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
TOM PETERSEN ARCHITECT, LLC110/18/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
KAMTECH RESTORATION CORP203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
KAMTECH RESTORATION CORPGeneral Contractor104/09/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
THOMAS PETERSEN ARCHITECT7854110/18/2025
Building Lifecycle
All (9)Filed (1)Permit Issued (1)Signed Off (1)Special Inspection (6)
12/30/2025
Signed off — Alteration
S01304579-I1
10/24/2025
Permit issued — Solar
S01304579-I1-SL
10/18/2025
Filed — Alteration
S01304579-I1
10/17/2025
Special inspection requirement — Flood Zone Compliance (attach FEMA elevation/dry floodproofing certificate where applicable)
TOM PETERSEN
10/17/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
TOM PETERSEN
10/17/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
TOM PETERSEN
10/17/2025
Special inspection requirement — Energy Code Compliance Inspections
TOM PETERSEN
10/17/2025
Special inspection requirement — Final
TOM PETERSEN
10/17/2025
Special inspection requirement — Air barrier - visual inspection
TOM PETERSEN
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarSigned-offKAMTECH RESTORATION CORP10/24/2025
1 project · most recent 10/13/2025
FiledStatusContractorScope
10/13/2025CompleteBERGER QUALITY ELEC'L CON—
▾Special Inspection Requirements (DOB NOW) — 6
DateRequirementInspectorRole
10/17/2025Flood Zone Compliance (attach FEMA elevation/dry floodproofing certificate where applicable)TOM PETERSENspecial
10/17/2025Fire-Resistant Penetrations and JointsTOM PETERSENspecial
10/17/2025Structural Stability – Alterations of existing buildingsTOM PETERSENspecial
10/17/2025Energy Code Compliance InspectionsTOM PETERSENprogress
10/17/2025FinalTOM PETERSENprogress
10/17/2025Air barrier - visual inspectionTOM PETERSENenergy_progress
▾Documents — 10 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/18/2026S01304579-I1Request digital key ↗
▸Seals & Professional Certifications7
▸DOB NOWProgress Inspector Seal & Signature3
08/27/2026S01304579-I1Open ↗
08/27/2026S01304579-I1Open ↗
08/27/2026S01304579-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature3
08/27/2026S01304579-I1Open ↗
08/27/2026S01304579-I1Open ↗
08/27/2026S01304579-I1Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/13/2026S01304579-I1Open ↗
▸Environmental & Asbestos1
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/13/2026S01304579-I1Open ↗
▸Approvals, Objections & Sign-offs1
▸DOB NOWUtility Company Final Acceptance Letter1
08/13/2026S01304579-I1Open ↗