← Back
One story retail building
3-24 ST NICHOLAS AVENUE
QUEENS · Ridgewood · BIN 4082319
💬 Discuss this project
1971Year Built
1Stories
K1Building Class
C4-3Zoning
25,000 sfGross Floor Area
1Units
0 Open Violations
One story retail building · Owner of record: 1580 GATES CO · 59,540 sf lot · 0.42 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbingFire Protection
Roof15p · 5 filings · 20 docs
Floor 26p · 2 filings · 20 docs
Floor 115p · 6 filings · 20 docs
Cellar2p · 1 filing · 3 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
BOGOPA SERVICE4107/08/2026
1580 GATES CO203/22/2026
LINE VENTURE GROUP103/22/2026
MSS CONST. CORP103/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
SAM MATHER ARCHITECT208/20/2024
NEWTEC ENGINEERING507/27/2023
MDG DESIGN GROUP209/06/2022
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
ZIUM ARCH403/21/2026
SAM MATHER ARCHITECT503/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
LINE VENTURE GROUP LLCGeneral Contractor2807/08/2026
AVON PLBG & HTG INCPlumbing307/08/2026
AVON PLBG & HTG INCFire Protection207/08/2026
ALLY HAZRATElectrical103/21/2026
ASKO ELEC CONST & MAIN INElectrical103/22/2026
HAZRAT ALLYElectrical103/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
APPLIED HVAC ENGINEERING,7563208/20/2024
OBAID MIAN849307/27/2023
SEAD ENGINEERING PC2665209/06/2022
Building Lifecycle
All (86)Filed (9)Permit Issued (15)Signed Off (1)Violation (4)Inspection (10)Objection (26)Special Inspection (21)
06/03/2026
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
04/22/2026
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
04/09/2026
Inspection — Fail-Final CND-Occupancy Inspection
Fail
View inspection ↗
02/03/2025
Signed off — Alteration
RENOVATE EXISTING GROCERY STORE:REMOVE NON-LOAD BEARING PARTITIONS, REMOVE DROPCEILING, RELOCATE EXISTING STORE ENTRY, NEW NON-LOADBEARING PARTITIONS, NEW FINISH FLOORING AND MILLWORK ASPER PLANS FILED. NO CHANGE IN USE, EGRESS OROCCUPANCY.
Q00577260-I1
11/15/2024
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
10/07/2024
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
10/04/2024
Inspection — Certified Sprinkler-SP-Fixtures-Finish
Certified
View inspection ↗
10/01/2024
Permit issued — Plumbing
Q00649621-I1-PL
09/30/2024
Permit issued — Sprinklers
Q00640661-I1-EW-SP
09/27/2024
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
09/20/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
Alexandra Herrera
09/20/2024
Special inspection requirement — Energy Code Compliance Inspections
Alexandra Herrera
09/20/2024
Special inspection requirement — Final
Alexandra Herrera
09/20/2024
Special inspection requirement — Interior lighting power
Alexandra Herrera
09/20/2024
Special inspection requirement — Insulation placement and R values
Alexandra Herrera
09/20/2024
Special inspection requirement — Lighting controls
Alexandra Herrera
08/29/2024
Objection resolved — Addressed
08/29/2024
Objection resolved — Addressed
08/28/2024
Objection raised — Other
08/28/2024
Objection raised — Structural
08/20/2024
Filed — Alteration
RENOVATE EXISTING GROCERY STORE:REMOVE NON-LOAD BEARING PARTITIONS, REMOVE DROPCEILING, RELOCATE EXISTING STORE ENTRY, NEW NON-LOADBEARING PARTITIONS, NEW FINISH FLOORING AND MILLWORK ASPER PLANS FILED. NO CHANGE IN USE, EGRESS OROCCUPANCY.
Q00577260-P1
07/29/2024
Special inspection requirement — Interior lighting power
Alexandra Herrera
07/29/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
Alexandra Herrera
07/29/2024
Special inspection requirement — Energy Code Compliance Inspections
Alexandra Herrera
07/29/2024
Special inspection requirement — Final
Alexandra Herrera
07/29/2024
Special inspection requirement — Insulation placement and R values
Alexandra Herrera
07/29/2024
Special inspection requirement — Lighting controls
Alexandra Herrera
02/21/2024
Permit issued — General Construction
Q00577260-I1-GC
09/15/2023
Permit issued — Mechanical Systems
Q00906820-I1-MS
08/21/2023
Objection resolved — Addressed
08/21/2023
Objection resolved — Addressed
08/21/2023
Objection resolved — Addressed
08/21/2023
Objection resolved — Addressed
08/21/2023
Objection resolved — Addressed
08/21/2023
Objection resolved — Addressed
08/03/2023
Objection raised — Admin
08/03/2023
Objection raised — Fire_Protection
08/03/2023
Objection raised — Scope
08/03/2023
Objection raised — Inspections
08/03/2023
Objection raised — Scope
08/03/2023
Objection raised — Zoning
07/27/2023
Filed — Alteration
INSTALLATION OF COMMERCIAL COOKING HOOD AND VENTILATION SYSTEM AS PER PLANS FILED. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
Q00906820-I1
05/02/2023
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/21/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
03/17/2023
Permit issued — Plumbing
Q00649621-I1-PL
03/03/2023
Permit issued — Sprinklers
Q00640661-I1-EW-SP
02/03/2023
Permit issued — Structural
Q00775046-I1-ST
02/03/2023
Permit issued — Mechanical Systems
Q00601693-I1-MS
02/03/2023
Permit issued — General Construction
Q00577260-I1-GC
12/08/2022
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
12/08/2022
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
12/07/2022
Permit issued — Mechanical Systems
Q00601693-I1-MS
09/21/2022
Violation issued (ECB, closed)
Unknown
09/09/2022
Permit issued — Structural
Q00775046-I1-ST
09/09/2022
Special inspection requirement — Structural Cold-Formed Steel
INHWAN CHANG
09/09/2022
Special inspection requirement — Structural Steel - Details
INHWAN CHANG
09/09/2022
Special inspection requirement — Masonry
INHWAN CHANG
09/09/2022
Special inspection requirement — Structural Steel - Welding
INHWAN CHANG
09/09/2022
Special inspection requirement — Structural Steel - High Strength Bolting
INHWAN CHANG
09/09/2022
Special inspection requirement — Structural Stability – Alterations of existing buildings
INHWAN CHANG
Latest 60 of 86 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedAVON PLBG & HTG INC10/01/2024
DOB NOWSprinklersPermit IssuedAVON PLBG & HTG INC09/30/2024
DOB NOWGeneral ConstructionSigned-offLINE VENTURE GROUP LLC02/21/2024
DOB NOWMechanical SystemsPermit IssuedLINE VENTURE GROUP LLC09/15/2023
DOB NOWPlumbingPermit IssuedAVON PLBG & HTG INC03/17/2023
DOB NOWSprinklersPermit IssuedAVON PLBG & HTG INC03/03/2023
DOB NOWStructuralSigned-offLINE VENTURE GROUP LLC02/03/2023
DOB NOWMechanical SystemsPermit IssuedLINE VENTURE GROUP LLC02/03/2023
DOB NOWGeneral ConstructionSigned-offLINE VENTURE GROUP LLC02/03/2023
DOB NOWMechanical SystemsPermit IssuedLINE VENTURE GROUP LLC12/07/2022
DOB NOWStructuralSigned-offLINE VENTURE GROUP LLC09/09/2022
DOB NOWGeneral ConstructionSigned-offLINE VENTURE GROUP LLC09/08/2022
DOB NOWPlumbingPermit IssuedAVON PLBG & HTG INC02/08/2022
DOB NOWMechanical SystemsPermit IssuedLINE VENTURE GROUP LLC01/01/2022
DOB NOWGeneral ConstructionSigned-offLINE VENTURE GROUP LLC10/05/2021
BISOTISSUEDJSEO STUDIO INC08/15/2014
BISMHISSUEDRELIABLE H.I. INC01/20/2011
BISOTISSUEDRELIABLE H.I. INC01/20/2011
BISOTISSUEDTHREE STAR CONSTRUCTION C04/21/2010
BIS—ISSUEDNEW YORK SIGN CONTRACTOR04/21/2010
BIS—ISSUEDNEW YORK SIGN CONTRACTOR04/21/2010
BISEQISSUEDM.S.S. CONSTRUCTION CORP08/12/2009
BISPLISSUEDPLUMBING & HTG DOCTOR INC04/09/2009
BISMHISSUEDGRACECON CORP11/19/2008
BISOTISSUEDKANG SAN CONSTRUCTION, INC.09/08/2008
1 project · most recent 07/27/2023
Heating Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
07/27/2023Permit IssuedLINE VENTURE GROUP LLCHeating Systems, Ventilation Systems
Heating
Captiveaire A2-D250-20D 3,200 CFM ×1
Ventilation
Dayton 56JN94 36,000 CFM · Exhaust Fan ×1
1 project · most recent 01/06/2022
FiledStatusContractorScope
01/06/2022Permit IssuedAVON PLBG & HTG INC—
1 project · most recent 12/22/2021
Gas Water/Sanitary
FiledStatusContractorScope
12/22/2021Permit IssuedAVON PLBG & HTG INCGas, Water/Sanitary
7 projects · most recent 01/23/2026
General Wiring
FiledStatusContractorScope
01/23/2026Permit IssuedJAM ELECTRICAL CORP—
10/10/2023Permit IssuedASKO ELEC CONST & MAIN IN—
10/10/2023Permit IssuedASKO ELEC CONST & MAIN IN—
10/27/2022Permit IssuedJAM ELECTRICAL CORP—
09/12/2022Permit IssuedASKO ELEC CONST & MAIN IN—
09/09/2022Permit IssuedASKO ELEC CONST & MAIN IN—
08/30/2022Permit IssuedASKO ELEC CONST & MAIN INGeneral Wiring
1 project · most recent 09/06/2022
Steel Concrete Masonry
FiledStatusContractorScope
09/06/2022Signed-offLINE VENTURE GROUP LLCSteel, Concrete, Masonry
▾Field Inspections (DOB CAP) — 10
DateTypeResultReport
06/03/2026Pass-Final CND-Occupancy InspectionPassView ↗
04/22/2026Pass-Final CND-Occupancy InspectionPassView ↗
04/09/2026Fail-Final CND-Occupancy InspectionFailView ↗
11/15/2024Pass-Final CND-Occupancy InspectionPassView ↗
10/07/2024Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
10/04/2024Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
09/27/2024Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
03/21/2023Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
12/08/2022Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
12/08/2022Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 21
DateRequirementInspectorRole
09/20/2024Fire-Resistant Penetrations and JointsAlexandra Herreraspecial
09/20/2024Energy Code Compliance InspectionsAlexandra Herreraprogress
09/20/2024FinalAlexandra Herreraprogress
09/20/2024Interior lighting powerAlexandra Herreraenergy_progress
09/20/2024Insulation placement and R valuesAlexandra Herreraenergy_progress
09/20/2024Lighting controlsAlexandra Herreraenergy_progress
07/29/2024Interior lighting powerAlexandra Herreraenergy_progress
07/29/2024Fire-Resistant Penetrations and JointsAlexandra Herreraspecial
07/29/2024Energy Code Compliance InspectionsAlexandra Herreraprogress
07/29/2024FinalAlexandra Herreraprogress
07/29/2024Insulation placement and R valuesAlexandra Herreraenergy_progress
07/29/2024Lighting controlsAlexandra Herreraenergy_progress
09/09/2022Structural Cold-Formed SteelINHWAN CHANGspecial
09/09/2022Structural Steel - DetailsINHWAN CHANGspecial
09/09/2022MasonryINHWAN CHANGspecial
09/09/2022Structural Steel - WeldingINHWAN CHANGspecial
09/09/2022Structural Steel - High Strength BoltingINHWAN CHANGspecial
09/09/2022Structural Stability – Alterations of existing buildingsINHWAN CHANGspecial
09/09/2022Concrete - Cast-In-PlaceINHWAN CHANGspecial
09/09/2022FinalYUNHO LEEprogress
12/02/2021Sprinkler SystemsObaid Mianspecial
▾Documents — 189 on file (BIS + DOB NOW)
▸Plans & Drawings9
▸DOB NOWPlans/Sketch9
08/27/2026Q00577260-P1Request digital key ↗
08/27/2026Q00577260-I1Request digital key ↗
08/27/2026Q00601674-I1Request digital key ↗
Showing 3 of 9 on file for this type
▸Applications & Permits31
▸BISPLAN / WORK APPROVAL APPLICATION17
12/26/2014420996514Open ↗
08/20/2014420996514Open ↗
01/11/2011410194622Open ↗
Showing 3 of 17 on file for this type
▸BISWORK PERMIT APPLICATION10
08/26/2014420996514Open ↗
01/24/2011410194622Open ↗
01/24/2011420303184Open ↗
Showing 3 of 10 on file for this type
▸BISNon-Directive 14 Construction Sign Off Including Sign Applications4
03/11/2015420996514Open ↗
11/04/2010420160578Open ↗
10/28/2010420160523Open ↗
Showing 3 of 4 on file for this type
▸Seals & Professional Certifications51
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION12
03/11/2015420996514Open ↗
08/20/2014420996514Open ↗
05/03/2011410194622Open ↗
Showing 3 of 12 on file for this type
▸DOB NOWProgress Inspector Seal & Signature11
09/01/2026Q00775046-I1Open ↗
08/25/2026Q00577260-I1Open ↗
08/25/2026Q00577260-I1Open ↗
Showing 3 of 11 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature10
09/01/2026Q00775046-I1Open ↗
09/01/2026Q00775046-I1Open ↗
09/01/2026Q00775046-I1Open ↗
Showing 3 of 10 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature9
08/27/2026Q00601674-I1Open ↗
08/26/2026Q00601693-I1Open ↗
08/26/2026Q00649621-I1Open ↗
Showing 3 of 9 on file for this type
▸BISPROFESSIONAL CERTIFIED CHECKLIST5
12/26/2014420996514Open ↗
08/20/2014420996514Open ↗
11/19/2008410194622Open ↗
Showing 3 of 5 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM3
11/19/2008410194622Open ↗
06/25/2008410130246Open ↗
06/10/2008410122362Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
08/20/2014420996514Open ↗
▸Trade Schedules & Equipment23
▸BISEQUIPMENT USE PERMITS16
03/21/2015420996514Open ↗
03/21/2015420996514Open ↗
03/21/2015420996514Open ↗
Showing 3 of 16 on file for this type
▸BISEQUIPMENT USE APPLICATION-PERMIT4
05/03/2011410194622Open ↗
05/03/2011410194622Open ↗
03/19/2015420996514Open ↗
Showing 3 of 4 on file for this type
▸BISSCHEDULE B - PLUMBING2
05/20/2010420051053Open ↗
11/19/2008410194622Open ↗
▸BISSELF-CERT PLUMBING NOTICE1
04/27/2009410194622Open ↗
▸Safety & Tenant Protection4
▸BISSTREET TREE CHECKLIST4
03/24/2010420160587Open ↗
03/24/2010420160523Open ↗
03/24/2010420160578Open ↗
Showing 3 of 4 on file for this type
▸Environmental & Asbestos19
▸DOB NOWDEP ACP-5: Asbestos Assessment Report9
08/27/2026Q00601674-I1Open ↗
08/26/2026Q00601693-I1Open ↗
08/24/2026Q00906820-I1Open ↗
Showing 3 of 9 on file for this type
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'6
03/24/2010420160587Open ↗
03/24/2010420160523Open ↗
03/24/2010420160578Open ↗
Showing 3 of 6 on file for this type
▸BISASBESTOS EXEMPTION CERTIFICATION LETTER2
01/06/2011420303184Open ↗
06/10/2008410122362Open ↗
▸BISASBESTOS-EXEMPTION (ASB4)1
01/06/2011420303184Open ↗
▸BISACP5 ASBESTOS: CERTIFICATION (DEP ACP5)1
08/20/2014420996514Open ↗
▸Energy Compliance4
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS1
08/20/2014420996514Open ↗
▸BISTR8: Energy Code Progress Inspections1
03/11/2015420996514Open ↗
▸BISAS-BUILT ENERGY ANALYSIS1
03/11/2015420996514Open ↗
▸DOB NOWEN2: As Built Energy Analysis.1
08/13/2026Q00577260-I1Open ↗
▸Approvals, Objections & Sign-offs21
▸BISADMINISTRATIVE OBJECTIONS9
08/20/2014420996514Open ↗
01/06/2011420303184Open ↗
03/24/2010420160587Open ↗
Showing 3 of 9 on file for this type
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST8
03/19/2015420996514Open ↗
03/11/2015420996514Open ↗
05/03/2011410194622Open ↗
Showing 3 of 8 on file for this type
▸BISSUPERSEDING LETTER2
01/24/2011410194622Open ↗
01/24/2011420303184Open ↗
▸BISLETTERS - SUPPORTING DOCUMENTATION1
03/15/2011420303184Open ↗
▸BISSCHEDULE A - OCCUPANCY / USE1
05/20/2010420051053Open ↗
▸Cost, Insurance & Ownership16
▸BISCOST AFFIDAVIT16
03/11/2015420996514Open ↗
08/20/2014420996514Open ↗
05/03/2011410194622Open ↗
Showing 3 of 16 on file for this type
▸Filing & Intake Forms10
▸BISEFILING COVER SHEET9
08/20/2014420996514Open ↗
01/06/2011420303184Open ↗
03/24/2010420160587Open ↗
Showing 3 of 9 on file for this type
▸BISADDITIONAL INFORMATION1
09/14/2010420160523Open ↗
▸Other Documents1
▸BISPLOT DIAGRAM1
05/20/2010420051053Open ↗