HPD08/17/2026§ 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 11, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST
HPD08/17/2026§ 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 11, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST
HPD05/29/2026§ 27-2005 HMC: REFIT DOOR IN THE 2nd ROOM FROM EAST LOCATED AT APT 1, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST
HPD05/29/2026§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING. IN THE KITCHEN LOCATED AT APT 1, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST
HPD05/29/2026§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE VINYL FLOORTILES IN THE 3rd ROOM FROM EAST LOCATED AT APT 1, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST
ECB10/21/2025WORK WITHOUT PERMIT ELECTRICAL WORK ON EXTENSION WORK AREA OUTSIDE OF THE BUILDING WITH METAL AND PLASTIC APPROX. 35FT L X8FT W X 9FT H SETTING AREA WITH TABLE AND CHAIR AT THAT AREA ELECTRICAL LIGHT HANGING.,$6K due
ECB10/21/2025WORK WITHOUT PERMIT ELECTRICAL WORK INDIRECT LIGHT " PIZZA & PASTA CORP" , SIGN WITH ELECTRICAL LIGHT MENTION " CHUROS THAI" ., OBTAIN ALL PERMITS$6K due
ECB10/21/2025WORK WITHOUT PERMIT TWO BUSINESS ACCESSORY SIGN FACING 101 STREET, ONE SIGN APPROX. 35FT X 2.5FT MENTION "PIZZA &PASTA CORP& ONE SIGN ON AWNING APPROX.25 FT X2.5FFT X2.5FT MENTION " ROSENTHAL WINE MERCHANT" . L$500 due
ECB10/21/2025WORK WITHOUT PERMIT EXTENSION WORK OUTSIDE OF THE BUILDING WITH METAL AND PLASTIC APPROX. 35FT L X8FT W X 9FT H SETTING AREA WITH TABLE AND CHAIR., OBTAIN PERMIT OR RESTORE PREMISES TO PRIOR LEGAL CONDITION$500 due
DOB10/02/2025FTC W/COMMISSIONER'S ORDER CONTROL#341125 VIO#072525PI11102HZ DATED 07/29/25 REQUIRING OWNER TO START BLDG REPAIRS UNDER PERMIT. AS OF 10/2/25 THERE ARE NO JOBS IN BIS OR DOBNOW TO REPAIR BLDG. IMMED COMPLY W/COMMISSIONER'S ORDER 341425 VIO#072925PI11102HZ TO REPAIR THE BUILDING UNDER PERMIT
DOB07/29/2025FTM BLDG IN CODE COMPLIANT MANNER-OBSVD CRACKED ORNAMENTAL LIMESTONE HEADER WINDOW & MISSING MORTAR BTWN STONES @ VARIOUS LOCATIONS FACING LEXINGTON AVE AND ON EAST 101 ST. OWNER TO IMMED RETAIN NYSPE TO EVAL ENTIRE BLDG TO DETEMINE THE STRUCT STAB & PREPARE/FILE DWGS. REPAIR BLDG UNDER PERMIT STARTING BY 08/28/25 COMPL/SIGNED OFF BY 09/29/25
HPD06/06/2025§ 27-2005 ADM CODE PAINT METAL IN ACCORDANCE WITH DEPT. REGULATION AT HEATRISER AT WEST WALL IN THE 2nd ROOM FROM EAST AT SOUTH LOCATED AT APT 1, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST
DOB09/23/2024VIOLATION ISSUED-FAILURE TO FILE 2023 EXTERNAL LOW PRESSURE INSPECTION
DOB04/25/2023VIOLATION ISSUED-FAILURE TO FILE 2022 EXTERNAL LOW PRESSURE INSPECTION
HPD01/03/2023§ 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK AT CEILING IN THE 1st ROOM FROM NORTH LOCATED AT APT 21, 6th STORY, 1st APARTMENT FROM SOUTH AT WEST
HPD04/04/2022§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE VINYL FLOOR TILES IN THE 1st ROOM FROM NORTH LOCATED AT APT 9, 3rd STORY, 3rd APARTMENT FROM SOUTH AT WEST
HPD04/04/2022§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE 1st BATHROOM FROM NORTH LOCATED AT APT 9, 3rd STORY, 3rd APARTMENT FROM SOUTH AT WEST
HPD04/04/2022§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 1st BATHROOM FROM NORTH LOCATED AT APT 9, 3rd STORY, 3rd APARTMENT FROM SOUTH AT WEST
HPD01/22/2022§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT EAST WALL IN THE 2nd ROOM FROM NORTH LOCATED AT APT 21, 6th STORY, 1st APARTMENT FROM EAST AT SOUTH
HPD01/22/2022§ 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK AT CEILING IN THE 1st ROOM FROM NORTH LOCATED AT APT 21, 6th STORY, 1st APARTMENT FROM EAST AT SOUTH
HPD09/30/2020§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE UNEVEN WOOD FLOOR IN THE 1st ROOM FROM EAST LOCATED AT APT 9, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST
HPD08/08/2017§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE KITCHEN LOCATED AT APT 9, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST
HPD08/08/2017§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE AT WOOD FLOOR IN THE 3rd ROOM FROM NORTH LOCATED AT APT 9, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST
HPD08/08/2017§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE AT WOOD FLOOR IN THE 2nd ROOM FROM NORTH LOCATED AT APT 9, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST