← Back
Two family frame
16-33 166 STREET
QUEENS · BIN 4128718
💬 Discuss this project
1950Year Built
2Stories
B2Building Class
R3XZoning
4,526 sfGross Floor Area
2Units
0 Open ViolationsFDNY Report ↗
Two family frame · Owner of record: LIN, MEI NA · 7,800 sf lot · 0.58 FAR built · Flood zone X
Locations of Work
ArchitectureStructural
Floor 213p · 1 filing · 20 docs
Floor 113p · 1 filing · 20 docs
Cellar14p · 1 filing · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
SPLEN CONSTRUCTION603/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
05/28/2024$2.3M—— → —$517/sf building
05/27/2021$1.1M—— → —$243/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
MEI ARCHITECT PLLC705/19/2023
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
IBUILD CONSULTING1403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
L&L CONSTRUCTION DEVELOPGeneral Contractor603/21/2026
SPLEN CONSTRUCTION INCGeneral Contractor407/08/2026
HP SERVICES INCPlumbing107/08/2026
XH&RC PLBG AND HTG INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
MEHDI GHAZI, P.E. P.C.7129505/19/2023
TRIANGLE INSPECTION & TES7495305/16/2023
Building Lifecycle
All (71)Filed (7)Permit Issued (6)Signed Off (4)Violation (6)Inspection (8)Objection (10)Special Inspection (30)
01/22/2025
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
02/02/2024
Signed off — ALT-CO - New Building with Existing Elements to Remain
PROPOSED ENLARGEMENT FOR TWO-FAMILY DETACHED RESIDENCE. OBTAN A NEW CERTIFICATE OF OCCUPANCY.
Q00586128-I1
09/28/2023
Signed off — Alteration
INSTALLATION OF PLUMBING WORK IN CONJUNCTION WITH JOB #Q00586128 AND #Q00693100 AS PER PLAN FILED HEREWITH. NO CHANGE IN USE, OCCUPANCY OR EGRESS.
Q00625135-I1
08/24/2023
Signed off — Alteration
INSTALLATION OF NEW CURB CUT AS PER PLAN FILED HEREWITH. NO CHANGE IN USE, OCCUPANCY OR EGRESS.
Q08021815-I1
08/22/2023
Signed off — Alteration
INSTALLATION OF CONSTRUCTION FENCE AS PER PLAN FILED HEREWITH. NO CHANGE IN USE, OCCUPANCY OR EGRESS.
Q00627089-I1
08/22/2023
Inspection — Pass-Final Curb Cut Non-Directive 14
Pass
View inspection ↗
08/21/2023
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
08/18/2023
Permit issued — Curb Cut
Q08021815-I1-CC
06/13/2023
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
06/07/2023
Permit issued — Plumbing
Q00625135-I1-PL
05/24/2023
Special inspection requirement — Fire-Resistance Rated Construction
MEHDI GHAZI
05/24/2023
Special inspection requirement — HVAC-R and service water heating system controls
MEHDI GHAZI
05/24/2023
Special inspection requirement — Chimneys and vents
MEHDI GHAZI
05/24/2023
Special inspection requirement — Structural Wood Frame
MEHDI GHAZI
05/24/2023
Special inspection requirement — Ventilation and air distribution system
MEHDI GHAZI
05/24/2023
Special inspection requirement — Permanent certificate
MEHDI GHAZI
05/24/2023
Special inspection requirement — Concrete - Cast-In-Place
MEHDI GHAZI
05/24/2023
Special inspection requirement — Heating Systems
MEHDI GHAZI
05/24/2023
Special inspection requirement — Subsurface Investigations (Borings/Test Pits)
Rajasekhar Sakhamuri
05/24/2023
Special inspection requirement — Mechanical Systems
MEHDI GHAZI
05/24/2023
Special inspection requirement — Final
MEHDI GHAZI
05/24/2023
Special inspection requirement — Air barrier continuity plan testing
MEHDI GHAZI
05/24/2023
Special inspection requirement — Interior lighting power
MEHDI GHAZI
05/24/2023
Special inspection requirement — Air barrier - visual inspection
MEHDI GHAZI
05/24/2023
Special inspection requirement — Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation
MEHDI GHAZI
05/24/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
MEHDI GHAZI
05/24/2023
Special inspection requirement — Structural Steel - Details
MEHDI GHAZI
05/24/2023
Special inspection requirement — Structural Steel - Welding
MEHDI GHAZI
05/24/2023
Special inspection requirement — Structural Stability – Alterations of existing buildings
MEHDI GHAZI
05/24/2023
Special inspection requirement — Structural Steel - High Strength Bolting
MEHDI GHAZI
05/24/2023
Special inspection requirement — Masonry
MEHDI GHAZI
05/24/2023
Special inspection requirement — Excavations - Sheeting, Shoring, and Bracing
MEHDI GHAZI
05/24/2023
Special inspection requirement — Energy Code Compliance Inspections
MEHDI GHAZI
05/24/2023
Special inspection requirement — Footing and Foundation
MEHDI GHAZI
05/24/2023
Special inspection requirement — Electric vehicle service equipment requirements
MEHDI GHAZI
05/24/2023
Special inspection requirement — Metering
MEHDI GHAZI
05/24/2023
Special inspection requirement — Air barrier — testing
MEHDI GHAZI
05/24/2023
Special inspection requirement — Fenestration and door U-factor and product ratings
MEHDI GHAZI
05/24/2023
Special inspection requirement — HVAC-R and service water heating equipment
MEHDI GHAZI
05/24/2023
Special inspection requirement — Insulation placement and R values
MEHDI GHAZI
05/19/2023
Filed — ALT-CO - New Building with Existing Elements to Remain
PROPOSED ENLARGEMENT FOR TWO-FAMILY DETACHED RESIDENCE. OBTAN A NEW CERTIFICATE OF OCCUPANCY.
Q00586128-P1
05/16/2023
Filed — Alteration
INSTALLATION OF PLUMBING WORK IN CONJUNCTION WITH JOB #Q00586128 AND #Q00693100 AS PER PLAN FILED HEREWITH. NO CHANGE IN USE, OCCUPANCY OR EGRESS.
Q00625135-P2
04/04/2023
Objection raised — Inspections
04/04/2023
Objection resolved — Addressed
03/28/2023
Objection raised — Inspections
03/28/2023
Objection resolved — Addressed
03/21/2023
Filed — Alteration
INSTALLATION OF NEW CURB CUT AS PER PLAN FILED HEREWITH. NO CHANGE IN USE, OCCUPANCY OR EGRESS.
Q08021815-I1
03/07/2023
Permit issued — Structural
Q00586128-I1-GC-CX
09/29/2022
Violation issued (ECB, closed)
Construction
09/07/2022
Violation issued (ECB, closed)
Construction
07/08/2022
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
07/08/2022
Inspection — Certified Storm Drainage-ST-Piping-Underground
Certified
View inspection ↗
07/08/2022
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
07/08/2022
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
06/11/2022
Filed — Alteration
INSTALLATION OF PLUMBING WORK IN CONJUNCTION WITH JOB #Q00586128 AND #Q00693100 AS PER PLAN FILED HEREWITH. NO CHANGE IN USE, OCCUPANCY OR EGRESS.
Q00625135-P1
05/18/2022
Violation issued (ECB, closed)
Construction
05/18/2022
Violation issued (ECB, closed)
Construction
04/20/2022
Permit issued — Plumbing
Q00625135-I1-PL
04/20/2022
Violation issued (ECB, closed)
Construction
04/20/2022
Violation issued (ECB, closed)
Construction
Latest 60 of 71 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWCurb CutSigned-offL&L CONSTRUCTION DEVELOP08/18/2023
DOB NOWPlumbingSigned-offHP SERVICES INC06/07/2023
DOB NOWStructuralPermit IssuedL&L CONSTRUCTION DEVELOP03/07/2023
DOB NOWPlumbingSigned-offXH&RC PLBG AND HTG INC04/20/2022
DOB NOWGeneral ConstructionPermit IssuedSPLEN CONSTRUCTION INC04/12/2022
DOB NOWConstruction FenceSigned-offSPLEN CONSTRUCTION INC03/22/2022
1 project · most recent 05/19/2023
Heating Systems
FiledStatusContractorScopeMake / Model / Capacity
05/19/2023Permit IssuedL&L CONSTRUCTION DEVELOPHeating Systems
Heating
Williamson GWA-140 140,000 BTU · Boiler ×4
1 project · most recent 03/22/2022
General Wiring
FiledStatusContractorScope
03/22/2022CompleteKJK ELECTRIC INCGeneral Wiring
1 project · most recent 05/19/2023
Steel Wood
FiledStatusContractorScope
05/19/2023Permit IssuedL&L CONSTRUCTION DEVELOPSteel, Wood
1 project · most recent 05/19/2023
Earthwork
FiledStatusContractorScope
05/19/2023Permit IssuedL&L CONSTRUCTION DEVELOPEarthwork
▾Field Inspections (DOB CAP) — 8
DateTypeResultReport
01/22/2025Pass-Final CND-Occupancy InspectionPassView ↗
08/22/2023Pass-Final Curb Cut Non-Directive 14PassView ↗
08/21/2023Pass-Final CND-Occupancy InspectionPassView ↗
06/13/2023Pass-Final PL - Up to 3 Requested FloorsPassView ↗
07/08/2022Certified Gas-Gas-Piping-RoughingCertifiedView ↗
07/08/2022Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
07/08/2022Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
07/08/2022Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 91
DateRequirementInspectorRole
05/24/2023Air barrier continuity plan testingMEHDI GHAZIenergy_progress
05/24/2023MeteringMEHDI GHAZIenergy_progress
05/24/2023Electric vehicle service equipment requirementsMEHDI GHAZIenergy_progress
05/24/2023FinalMEHDI GHAZIprogress
05/24/2023Footing and FoundationMEHDI GHAZIprogress
05/24/2023Energy Code Compliance InspectionsMEHDI GHAZIprogress
05/24/2023Fenestration air leakageMEHDI GHAZIenergy_progress
05/24/2023HVAC-R and service water piping design and insulationMEHDI GHAZIenergy_progress
05/24/2023Maintenance informationMEHDI GHAZIenergy_progress
05/24/2023Fenestration areasMEHDI GHAZIenergy_progress
05/24/2023Fire-Resistance Rated ConstructionMEHDI GHAZIprogress
05/24/2023Duct leakage testing, insulation and designMEHDI GHAZIenergy_progress
05/24/2023Insulation placement and R valuesMEHDI GHAZIenergy_progress
05/24/2023HVAC-R and service water heating system controlsMEHDI GHAZIenergy_progress
05/24/2023Permanent certificateMEHDI GHAZIenergy_progress
05/24/2023Air barrier - visual inspectionMEHDI GHAZIenergy_progress
05/24/2023HVAC-R and service water heating equipmentMEHDI GHAZIenergy_progress
05/24/2023Interior lighting powerMEHDI GHAZIenergy_progress
05/24/2023Fenestration and door U-factor and product ratingsMEHDI GHAZIenergy_progress
05/24/2023Air barrier — testing MEHDI GHAZIenergy_progress
05/24/2023Ventilation and air distribution systemMEHDI GHAZIenergy_progress
05/24/2023Private On-Site Storm Water Disposal Systems-, and Detention Facilities, InstallationMEHDI GHAZIspecial
05/24/2023Fire-Resistant Penetrations and JointsMEHDI GHAZIspecial
05/24/2023Concrete - Cast-In-PlaceMEHDI GHAZIspecial
05/24/2023Structural Steel - DetailsMEHDI GHAZIspecial
Latest 25 of 91.
▾Documents — 71 on file (BIS + DOB NOW)
▸Plans & Drawings7
▸DOB NOWPlans/Sketch7
08/26/2026Q00627089-I1Request digital key ↗
08/26/2026Q00625135-P2Request digital key ↗
08/26/2026Q00625135-I1Request digital key ↗
Showing 3 of 7 on file for this type
▸Applications & Permits4
▸BISBPP-5 - Authorization to the Department of Transportation3
05/03/2023440693796Open ↗
10/21/2022440693796Open ↗
11/18/2021440693796Open ↗
▸BISPLAN / WORK APPROVAL APPLICATION1
11/18/2021440693796Open ↗
▸Zoning, Tax Lot & Property Records3
▸DOB NOWZD1: DOB Zoning Diagram2
08/13/2026Q00586128-I1Open ↗
08/13/2026Q00586128-P1Open ↗
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026Q00586128-I1Open ↗
▸Seals & Professional Certifications29
▸DOB NOWSpecial Inspector Seal & Signature10
08/25/2026Q00586128-I1Open ↗
08/25/2026Q00586128-I1Open ↗
08/24/2026Q00625135-I1Open ↗
Showing 3 of 10 on file for this type
▸DOB NOWProgress Inspector Seal & Signature10
08/25/2026Q00586128-I1Open ↗
08/25/2026Q00586128-I1Open ↗
08/24/2026Q00625135-I1Open ↗
Showing 3 of 10 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature7
08/26/2026Q00625135-P2Open ↗
08/26/2026Q00625135-P1Open ↗
08/26/2026Q00625135-I1Open ↗
Showing 3 of 7 on file for this type
▸BISAPPLICANT OWNER SIGNATURE1
11/18/2021440693796Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
11/18/2021440693796Open ↗
▸Trade Schedules & Equipment2
▸DOB NOWDEP: Sewer Certification (Sanitary/Storm)2
08/13/2026Q00586128-P1Open ↗
08/13/2026Q00586128-I1Open ↗
▸Safety & Tenant Protection2
▸BISSTREET TREE CHECKLIST2
05/03/2023440693796Open ↗
11/18/2021440693796Open ↗
▸Environmental & Asbestos5
▸DOB NOWDEP ACP-5: Asbestos Assessment Report5
08/26/2026Q00625135-P2Open ↗
08/26/2026Q00625135-P1Open ↗
08/26/2026Q00625135-I1Open ↗
Showing 3 of 5 on file for this type
▸Energy Compliance2
▸DOB NOWEN2: As Built Energy Analysis.2
08/13/2026Q00625135-I1Open ↗
08/13/2026Q00586128-I1Open ↗
▸Inspections & Test Reports4
▸DOB NOWSOIL REPORT2
08/13/2026Q00586128-P1Open ↗
08/13/2026Q00586128-I1Open ↗
▸DOB NOWTR4 Test Report and Plot Diagram1
08/13/2026Q00586128-I1Open ↗
▸DOB NOWTR4 Plot Diagram1
08/13/2026Q00586128-I1Open ↗
▸Approvals, Objections & Sign-offs1
▸BISBPP-8 - Request Items for Builders Pavement Plan Signoff1
11/22/2023440693796Open ↗
▸Filing & Intake Forms3
▸BISADDITIONAL INFORMATION2
05/03/2023440693796Open ↗
05/03/2023440693796Open ↗
▸BISEFILING JOB APPLICATION COVER SHEET1
11/18/2021440693796Open ↗
▸Other Documents9
▸DOB NOWSite Survey: Initial2
08/13/2026Q00586128-P1Open ↗
08/13/2026Q00586128-I1Open ↗
▸DOB NOWProperty Ownership Certification2
08/24/2026Q00586128-P1Open ↗
08/14/2026Q00586128-I1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone2
08/13/2026Q00586128-I1Open ↗
08/13/2026Q00586128-P1Open ↗
▸BISCONSTRUCTION - SUPPORTING DOCUMENTATION1
11/18/2021440693796Open ↗
▸DOB NOWAdjoining Owners Notification1
08/13/2026Q00586128-I1Open ↗
▸DOB NOWFinal Survey1
08/13/2026Q00586128-I1Open ↗