← Back
Miscellaneous indoor public assembly
16-61 WEIRFIELD STREET
QUEENS · Ridgewood · BIN 4085586
💬 Discuss this project
1975Year Built
1.5Stories
P9Building Class
M1-4DZoning
11,185 sfGross Floor Area
1Units
0 Open Violations
Miscellaneous indoor public assembly · Owner of record: RIDGEWOOD WEIRFIELD LLC · 7,680 sf lot · 1.46 FAR built · Flood zone X
Locations of Work
ArchitectureMechanicalPlumbingFire ProtectionGeneral
Filed — no permit issued57p · 4 filings · 18 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
MALACHITE GROUP LTD803/21/2026
AMTK REALTY403/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
FRANK J QUATELA ARCHITECT P.C401/27/2023
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
RIP CC403/21/2026
Manetta architecture design pllc403/21/2026
Building Lifecycle
All (57)Filed (4)Violation (5)Objection (31)Special Inspection (17)
01/30/2023
Objection raised — Zoning
01/30/2023
Objection resolved — Addressed
01/30/2023
Objection raised — Fire_Protection
01/30/2023
Objection resolved — Addressed
01/30/2023
Objection raised — Fire_Protection
01/30/2023
Objection resolved — Addressed
01/30/2023
Objection raised — Admin
01/30/2023
Objection resolved — Addressed
01/30/2023
Objection raised — Structural
01/30/2023
Objection resolved — Addressed
01/30/2023
Objection raised — Zoning
01/30/2023
Objection resolved — Addressed
01/30/2023
Objection raised — Scope
01/30/2023
Objection resolved — Addressed
01/30/2023
Objection raised — Scope
01/30/2023
Objection resolved — Addressed
01/30/2023
Objection raised — Structural
01/30/2023
Objection resolved — Addressed
01/30/2023
Objection raised — Structural
01/30/2023
Objection resolved — Addressed
01/30/2023
Objection raised — Fire_Protection
01/30/2023
Objection resolved — Addressed
01/30/2023
Objection raised — Fire_Protection
01/30/2023
Objection resolved — Addressed
01/27/2023
Filed — No Work
Q00818340-I1
01/25/2023
Filed — Alteration CO
2 STORY EXISTING COMMERCIAL BUILDING. FILING FOR CHANGE OF USE FROM PHYSICAL CULTURE ESTABLISHMENT (UG 9) TO EATING AND DRINKING ESTABLISHMENT (UG 12). INTERIOR RENOVATIONS AS SHOWN ON PLANS.
Q00813363-I1
01/16/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
01/16/2023
Special inspection requirement — Masonry
01/16/2023
Special inspection requirement — Energy Code Compliance Inspections
01/16/2023
Special inspection requirement — Fire-Resistance Rated Construction
01/16/2023
Special inspection requirement — Insulation placement and R values
01/16/2023
Special inspection requirement — Vestibules
01/16/2023
Special inspection requirement — Air barrier - visual inspection
05/24/2022
Objection raised — Structural
05/24/2022
Objection raised — Scope
05/24/2022
Objection raised — Mechanical
05/24/2022
Objection raised — Fire_Protection
05/24/2022
Objection raised — Accessibility
05/24/2022
Objection raised — Fire_Protection
05/24/2022
Objection raised — Mechanical
05/12/2022
Filed — Alteration
INTERIOR RENOVATION TO EXISTING PHYSICAL CULTURE ESTABLISHMENT. NEW PARTITIONS, FINISHES, AND DOOR AS PER PLANS. NEW PLUMBING FIXTURES FILED UNDER SEPARATE APPLICATION. NO CHANGE TO USE EGRESS, OR OCCUPANCY.
Q00726220-I1
05/12/2022
Filed — Alteration
Q00726142-I1
05/06/2022
Special inspection requirement — Air barrier - visual inspection
05/06/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
05/06/2022
Special inspection requirement — Fenestration air leakage
05/06/2022
Special inspection requirement — Fenestration and door U-factor and product ratings
05/06/2022
Special inspection requirement — Energy Code Compliance Inspections
05/06/2022
Special inspection requirement — Fire-Resistance Rated Construction
05/06/2022
Special inspection requirement — Fenestration areas
05/06/2022
Special inspection requirement — Interior lighting power
05/06/2022
Special inspection requirement — Lighting controls
05/06/2022
Special inspection requirement — Vestibules
12/31/2009
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
01/01/2009
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
12/15/2008
Violation issued (ECB, closed)
Construction
01/03/2008
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
01/03/2008
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
BISOTISSUEDJRS CONSTRUCTION & EXPEDITING07/06/2010
BISOTISSUEDJRS CONSTRUCTION & EXPEDITING07/06/2010
BIS—ISSUEDJOVIL CONTRACTING CORP.10/15/2004
BISSPISSUEDJ. CAIAZZO PLBG & HTG CORP05/27/2004
BIS—ISSUEDJOVIL CONTRACTING CORP.03/24/2004
BISPLISSUEDLEMODE PLBG & HTG CORP12/29/2003
BISPLISSUEDMATIELO PLUMBING & HEATING INC11/18/2003
BIS—ISSUEDNEW CENTURY CONSTRUCTION CO09/09/2003
1 project · most recent 01/25/2023
Air Conditioning Systems Heating and Air Conditioning Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
01/25/2023——Air Conditioning Systems, Heating and Air Conditioning Systems, Ventilation Systems
Cooling
Trane OAKD300D3 316,500 BTU · Rooftop Unit ×1
Heat / Cool
Trane NTXMSM48A182AA 43,000 BTU · Condensing Unit ×1
Ventilation
Neptronic CMU10G080DD 26,000 BTU · Makeup Air ×1
Task TGU430RT-NG-RAP 518,000 BTU · Makeup Air ×1
1 project · most recent 01/25/2023
Sprinkler System
FiledStatusContractorScope
01/25/2023——Sprinkler System
1 project · most recent 01/25/2023
Gas Water/Sanitary
FiledStatusContractorScope
01/25/2023——Gas, Water/Sanitary
▾Special Inspection Requirements (DOB NOW) — 17
DateRequirementInspectorRole
01/16/2023Fire-Resistant Penetrations and Joints—special
01/16/2023Masonry—special
01/16/2023Energy Code Compliance Inspections—progress
01/16/2023Fire-Resistance Rated Construction—progress
01/16/2023Insulation placement and R values—energy_progress
01/16/2023Vestibules—energy_progress
01/16/2023Air barrier - visual inspection—energy_progress
05/06/2022Air barrier - visual inspection—energy_progress
05/06/2022Fire-Resistant Penetrations and Joints—special
05/06/2022Fenestration air leakage—energy_progress
05/06/2022Fenestration and door U-factor and product ratings—energy_progress
05/06/2022Energy Code Compliance Inspections—progress
05/06/2022Fire-Resistance Rated Construction—progress
05/06/2022Fenestration areas—energy_progress
05/06/2022Interior lighting power—energy_progress
05/06/2022Lighting controls—energy_progress
05/06/2022Vestibules—energy_progress
▾Documents — 67 on file (BIS + DOB NOW)
▸Plans & Drawings6
▸DOB NOWPlans/Sketch5
08/26/2026Q00726142-I1Request digital key ↗
08/25/2026Q00813363-S1Request digital key ↗
08/25/2026Q00813363-S2Request digital key ↗
Showing 3 of 5 on file for this type
▸DOB NOWPlans/Sketch - Place of Assembly1
08/25/2026Q00818340-I1Request digital key ↗
▸Applications & Permits11
▸BISPLAN / WORK APPROVAL APPLICATION6
03/15/2023421815655Open ↗
10/24/2022401713428Open ↗
03/28/2011410223388Open ↗
Showing 3 of 6 on file for this type
▸BISPLACE OF ASSEMBLY2
03/25/2011410223388Open ↗
03/04/2009410223388Open ↗
▸BISWORK PERMIT APPLICATION2
07/06/2010420210532Open ↗
07/06/2010420210523Open ↗
▸BISPLACE OF ASSEMBLY APPLICATION1
04/27/2011410223388Open ↗
▸Zoning, Tax Lot & Property Records2
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026Q00813363-I1Open ↗
▸DOB NOWZoning Exhibit form (1-5)1
08/13/2026Q00813363-I1Open ↗
▸Seals & Professional Certifications21
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION8
07/19/2010420210532Open ↗
07/16/2010420210523Open ↗
07/06/2010420210532Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature4
08/26/2026Q00726142-I1Open ↗
08/25/2026Q00818340-I1Open ↗
08/13/2026Q00726220-I1Open ↗
Showing 3 of 4 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM3
07/06/2010420210532Open ↗
07/06/2010420210523Open ↗
03/04/2009410223388Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST3
07/06/2010420210532Open ↗
07/06/2010420210523Open ↗
03/04/2009410223388Open ↗
▸DOB NOWProgress Inspector Seal & Signature2
08/26/2026Q00726220-I1Open ↗
08/26/2026Q00726220-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/26/2026Q00726220-I1Open ↗
▸Safety & Tenant Protection2
▸BISSTREET TREE CHECKLIST1
03/04/2009410223388Open ↗
▸DOB NOWStreet Tree Checklist1
08/13/2026Q00813363-I1Open ↗
▸Environmental & Asbestos7
▸DOB NOWDEP ACP-5: Asbestos Assessment Report4
08/13/2026Q00726220-I1Open ↗
08/13/2026Q00813363-I1Open ↗
08/13/2026Q00813363-S1Open ↗
Showing 3 of 4 on file for this type
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'2
07/06/2010420210532Open ↗
07/06/2010420210523Open ↗
▸BISASBESTOS EXEMPTION CERTIFICATION LETTER1
03/04/2009410223388Open ↗
▸Approvals, Objections & Sign-offs8
▸BISLETTERS - SUPPORTING DOCUMENTATION3
04/27/2011410223388Open ↗
07/19/2010420210532Open ↗
07/16/2010420210523Open ↗
▸BISADMINISTRATIVE OBJECTIONS3
03/12/2011410223388Open ↗
07/06/2010420210532Open ↗
07/06/2010420210523Open ↗
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST2
07/19/2010420210532Open ↗
07/16/2010420210523Open ↗
▸Cost, Insurance & Ownership4
▸BISCOST AFFIDAVIT4
07/19/2010420210532Open ↗
07/16/2010420210523Open ↗
07/06/2010420210532Open ↗
Showing 3 of 4 on file for this type
▸Filing & Intake Forms4
▸BISEFILING COVER SHEET3
03/15/2023421815655Open ↗
07/06/2010420210532Open ↗
07/06/2010420210523Open ↗
▸BISBOROUGH INTAKE FORM1
03/15/2023421815655Open ↗
▸Other Documents2
▸DOB NOWProperty Ownership Certification1
08/13/2026Q00813363-I1Open ↗
▸DOB NOWAlternate Plan 11
08/25/2026Q00818340-I1Open ↗