← Back
Two family frame
160-18 107 AVENUE
QUEENS · South Jamaica · BIN 4215985
💬 Discuss this project
1955Year Built
2Stories
B2Building Class
R4Zoning
2,992 sfGross Floor Area
2Units
0 Open ViolationsFDNY Report ↗
Two family frame · 2,501 sf lot · 1.2 FAR built · Flood zone X
Locations of Work
ElectricalGeneral
Roof7p · 1 filing · 13 docs
Floor 11p · 1 filing · 13 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
05/19/2015$400K—Private party → Private party$134/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
PARKER AND WEST ENGINEERING, PLLC209/12/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
SUNRUN203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
SUNRUN INSTALLATION SVCGeneral Contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
PARKER AND WEST ENGINEERI5272209/12/2024
Building Lifecycle
All (17)Filed (2)Permit Issued (1)Signed Off (1)Violation (3)Special Inspection (10)
12/30/2024
Signed off — Alteration
FILING HEREWITH TAX ABATEMENT APPLICATION FOR INSTALLATION OF ROOF MOUNTED SOLAR PANELS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
Q01066418-I1
09/12/2024
Filed — Alteration
FILING HEREWITH TAX ABATEMENT APPLICATION FOR INSTALLATION OF ROOF MOUNTED SOLAR PANELS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
Q01066418-P1
09/12/2024
Special inspection requirement — Structural Stability – Alterations of existing buildings
Walid Abdulla
09/12/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
Walid Abdulla
09/12/2024
Special inspection requirement — Energy Code Compliance Inspections
Walid Abdulla
09/12/2024
Special inspection requirement — Final
Walid Abdulla
09/12/2024
Special inspection requirement — Air barrier - visual inspection
Walid Abdulla
08/13/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
Walid Abdulla
08/13/2024
Special inspection requirement — Structural Stability – Alterations of existing buildings
Walid Abdulla
08/13/2024
Special inspection requirement — Energy Code Compliance Inspections
Walid Abdulla
08/13/2024
Special inspection requirement — Final
Walid Abdulla
08/13/2024
Special inspection requirement — Air barrier - visual inspection
Walid Abdulla
07/03/2024
Permit issued — Solar
Q01066418-I1-SL
06/20/2024
Filed — Alteration
FILING HEREWITH TAX ABATEMENT APPLICATION FOR INSTALLATION OF ROOF MOUNTED SOLAR PANELS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
Q01066418-I1
08/24/2014
Violation issued (HPD, closed)
B
08/24/2014
Violation issued (HPD, closed)
A
08/24/2014
Violation issued (HPD, closed)
B
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarSigned-offSUNRUN INSTALLATION SVC07/03/2024
1 project · most recent 08/22/2024
General Wiring
FiledStatusContractorScope
08/22/2024CompleteSUNRUN SOLAR ELECTL CORPGeneral Wiring
▾Special Inspection Requirements (DOB NOW) — 10
DateRequirementInspectorRole
09/12/2024Structural Stability – Alterations of existing buildingsWalid Abdullaspecial
09/12/2024Fire-Resistant Penetrations and JointsWalid Abdullaspecial
09/12/2024Energy Code Compliance InspectionsWalid Abdullaprogress
09/12/2024FinalWalid Abdullaprogress
09/12/2024Air barrier - visual inspectionWalid Abdullaenergy_progress
08/13/2024Fire-Resistant Penetrations and JointsWalid Abdullaspecial
08/13/2024Structural Stability – Alterations of existing buildingsWalid Abdullaspecial
08/13/2024Energy Code Compliance InspectionsWalid Abdullaprogress
08/13/2024FinalWalid Abdullaprogress
08/13/2024Air barrier - visual inspectionWalid Abdullaenergy_progress
▾Documents — 13 on file (BIS + DOB NOW)
▸Seals & Professional Certifications11
▸DOB NOWProgress Inspector Seal & Signature6
08/24/2026Q01066418-I1Open ↗
08/24/2026Q01066418-I1Open ↗
08/24/2026Q01066418-I1Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature4
08/24/2026Q01066418-I1Open ↗
08/24/2026Q01066418-I1Open ↗
08/22/2026Q01066418-P1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/13/2026Q01066418-P1Open ↗
▸Environmental & Asbestos1
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/13/2026Q01066418-P1Open ↗
▸Approvals, Objections & Sign-offs1
▸DOB NOWUtility Company Final Acceptance Letter1
08/13/2026Q01066418-I1Open ↗