1955Year Built
1Stories
A2Building Class
R2AZoning
1,272 sfGross Floor Area
1Units
One story - permanent living quarter · 3,600 sf lot · 0.35 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralPlumbing
Roof2p · 2 filings · 14 docs
Floor 22p · 1 filing · 7 docs
Floor 1
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
702 149 STREET REALTY604/09/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
03/27/2017$450K—Private party → Private party$354/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
GREEN RIVER ENVIRONMENTAL ENGINEERI110/14/2025
ANETONNE ARCHITECTURE P.C.104/27/2023
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
NY State Solar LLC203/21/2026
OBUME ASSOCIATES CONSULTING I203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
NYSS LLCGeneral Contractor104/09/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
GREEN RIVER ENVIRONMENTAL7841110/14/2025
Building Lifecycle
All (4)Filed (2)Permit Issued (1)Signed Off (1)
12/12/2025
Signed off — Alteration
INSTALLATION OF PHOTOVOLTAIC SOLAR ARRAY ON EXISTING ROOF SYSTEM AS PER PLANS.
Q01301710-I1
10/20/2025
Permit issued — Solar
Q01301710-I1-SL
10/14/2025
Filed — Alteration
INSTALLATION OF PHOTOVOLTAIC SOLAR ARRAY ON EXISTING ROOF SYSTEM AS PER PLANS.
Q01301710-I1
04/27/2023
Filed — ALT-CO - New Building with Existing Elements to Remain
PROPOSED PARTIAL 2nd STORY FRAME DORMER ADDITION TO THE EAST SIDE OF EXISTING ONE FAMILY RESIDENCE AS PER PLANS AND OBTAIN PERMIT & CERTIFICATE OF COMPLETION.
Q00772202-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarSigned-offNYSS LLC10/20/2025
1 project · most recent 10/14/2025
FiledStatusContractorScope
10/14/2025CompleteNY SOLAR ELECTRICAL LLC—
▾Special Inspection Requirements (DOB NOW) — 16
DateRequirementInspectorRole
10/13/2025Structural Stability – Alterations of existing buildingsROBERT MASONEspecial
10/13/2025Energy Code Compliance InspectionsROBERT MASONEprogress
10/13/2025Fire-Resistant Penetrations and JointsROBERT MASONEspecial
10/13/2025FinalROBERT MASONEprogress
10/13/2025Air barrier - visual inspectionROBERT MASONEenergy_progress
06/11/2024Permanent certificate—energy_progress
06/11/2024Air barrier — testing —energy_progress
06/11/2024Fenestration areas—energy_progress
06/11/2024Air barrier - visual inspection—energy_progress
06/11/2024Insulation placement and R values—energy_progress
10/31/2022Energy Code Compliance InspectionsTOBECHI CHINDOHprogress
10/05/2022Lighting controls—energy_progress
10/05/2022Fenestration air leakage—energy_progress
10/05/2022Interior lighting power—energy_progress
10/05/2022Fenestration and door U-factor and product ratings—energy_progress
10/05/2022Structural Stability – Alterations of existing buildings—special
▾Documents — 14 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/18/2026Q01301710-I1Request digital key ↗
08/15/2026Q00772202-I1Request digital key ↗
▸Zoning, Tax Lot & Property Records1
▸DOB NOWZD1: DOB Zoning Diagram1
08/13/2026Q00772202-I1Open ↗
▸Seals & Professional Certifications5
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/24/2026Q00772202-I1Open ↗
08/18/2026Q01301710-I1Open ↗
▸DOB NOWProgress Inspector Seal & Signature2
08/25/2026Q01301710-I1Open ↗
08/25/2026Q01301710-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/25/2026Q01301710-I1Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/18/2026Q01301710-I1Open ↗
08/15/2026Q00772202-I1Open ↗
▸Approvals, Objections & Sign-offs1
▸DOB NOWUtility Company Final Acceptance Letter1
08/13/2026Q01301710-I1Open ↗
▸Other Documents3
▸DOB NOWSite Survey: Initial1
08/13/2026Q00772202-I1Open ↗
▸DOB NOWProperty Ownership Certification1
08/15/2026Q00772202-I1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone1
08/13/2026Q00772202-I1Open ↗