← Back
Two stories - detached, small or mid-size
160-43 96 STREET
QUEENS · Howard Beach-Lindenwood · BIN 4295577
💬 Discuss this project
1930Year Built
2.5Stories
A1Building Class
R2Zoning
1,952 sfGross Floor Area
1Units
Two stories - detached, small or mid-size · 4,000 sf lot · 0.49 FAR built · Flood zone VE
Locations of Work
ArchitecturePlumbing
Cellar6p · 2 filings · 16 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
06/29/2018$665K—TIGER GATE LLC → Private party$341/sf building
11/22/2017$405K—— → —$207/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
ARCALHEK206/18/2021
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
A&A BUILDING CONSULTANTS INC.403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
CITY BUILDING CONSULTANTSGeneral Contractor303/21/2026
SIGNORE & SONS PLBG CORPPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
ARCALHEK PC3340206/18/2021
Building Lifecycle
All (13)Filed (2)Permit Issued (2)Objection (2)Special Inspection (7)
08/19/2021
Permit issued — Plumbing
Q00542390-I1-PL
07/26/2021
Permit issued — General Construction
Q00541895-I1-GC
07/06/2021
Objection raised — Zoning
07/06/2021
Objection resolved — Addressed
06/18/2021
Filed — Alteration
propose new entrance to cellar.
Q00541895-I1
06/18/2021
Filed — Alteration
propose 3 pc bathroom in cellar.
Q00542390-I1
06/18/2021
Special inspection requirement — Fire-Resistant Penetrations and Joints
RAYMOND CALAMARI
06/18/2021
Special inspection requirement — Structural Stability – Alterations of existing buildings
RAYMOND CALAMARI
06/18/2021
Special inspection requirement — Energy Code Compliance Inspections
RAYMOND CALAMARI
06/18/2021
Special inspection requirement — Fire-Resistance Rated Construction
RAYMOND CALAMARI
06/18/2021
Special inspection requirement — Fenestration air leakage
RAYMOND CALAMARI
06/18/2021
Special inspection requirement — Fenestration and door U-factor and product ratings
RAYMOND CALAMARI
06/18/2021
Special inspection requirement — Insulation placement and R values
RAYMOND CALAMARI
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedSIGNORE & SONS PLBG CORP08/19/2021
DOB NOWGeneral ConstructionPermit IssuedCITY BUILDING CONSULTANTS07/26/2021
1 project · most recent 06/18/2021
Water/Sanitary
FiledStatusContractorScope
06/18/2021Permit IssuedSIGNORE & SONS PLBG CORPWater/Sanitary
▾Special Inspection Requirements (DOB NOW) — 7
DateRequirementInspectorRole
06/18/2021Fire-Resistant Penetrations and JointsRAYMOND CALAMARIspecial
06/18/2021Structural Stability – Alterations of existing buildingsRAYMOND CALAMARIspecial
06/18/2021Energy Code Compliance InspectionsRAYMOND CALAMARIprogress
06/18/2021Fire-Resistance Rated ConstructionRAYMOND CALAMARIprogress
06/18/2021Fenestration air leakageRAYMOND CALAMARIenergy_progress
06/18/2021Fenestration and door U-factor and product ratingsRAYMOND CALAMARIenergy_progress
06/18/2021Insulation placement and R valuesRAYMOND CALAMARIenergy_progress
▾Documents — 16 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/27/2026Q00542390-I1Request digital key ↗
08/14/2026Q00541895-I1Request digital key ↗
▸Zoning, Tax Lot & Property Records2
▸DOB NOWRestrictive Declaration/Easement 12
08/13/2026Q00542390-I1Open ↗
08/13/2026Q00541895-I1Open ↗
▸Seals & Professional Certifications9
▸DOB NOWProgress Inspector Seal & Signature5
08/23/2026Q00541895-I1Open ↗
08/23/2026Q00541895-I1Open ↗
08/23/2026Q00541895-I1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/27/2026Q00541895-I1Open ↗
08/13/2026Q00542390-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
08/23/2026Q00541895-I1Open ↗
08/23/2026Q00541895-I1Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/14/2026Q00541895-I1Open ↗
08/13/2026Q00542390-I1Open ↗
▸Energy Compliance1
▸DOB NOWEN2: As Built Energy Analysis.1
08/13/2026Q00541895-I1Open ↗