← Back
Single or multiple dwelling with stores or offices
160 CRESCENT STREET
BROOKLYN · Cypress Hills · BIN 3091687
💬 Discuss this project
1915Year Built
3Stories
S9Building Class
R5Zoning
5,925 sfGross Floor Area
7Units
Rent Stabilized7 Open Violations ▸FDNY Report ↗
Single or multiple dwelling with stores or offices · Owner of record: ZHENG RICHMOND REALTY INC. · 2,458 sf lot · 2.41 FAR built · Flood zone X
Locations of Work
Mechanical
Roof2p · 1 filing · 3 docs
Floor 13p · 1 filing · 3 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
160 CRESCENT DELI & GROCERY INC503/22/2026
ZHENG RICHMOND REALTY703/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
11/30/2016$1.8M—— → —$304/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
ASHRAF CORP111/27/2023
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
SUPERIOR FIRE CONTROL103/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
SUPERIOR FIRE CONTROL INCGeneral Contractor303/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
JAY KAVI CORPORATION8500111/27/2023
Building Lifecycle
All (29)Filed (1)Permit Issued (1)Violation (27)
12/16/2025
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
07/21/2025
Violation issued (FDNY_ORDER, closed)
07/21/2025
Violation issued (FDNY_ORDER, closed)
07/21/2025
Violation issued (FDNY_ORDER, closed)
07/21/2025
Violation issued (FDNY_ORDER, closed)
06/09/2025
Violation issued (HPD, closed)
A
11/26/2024
Violation issued (HPD, closed)
I
12/01/2023
Permit issued — Mechanical Systems
B00966194-I1-MS
11/27/2023
Filed — Alteration
INSTALL DELI KITCHEN HOOD AND DUCTWORK AS PER PLANS. NO CHANGE IN USE, ERGRESS OR OCCUPANCY.
B00966194-I1
03/22/2023
Violation issued (HPD, closed)
A
11/07/2022
Violation issued (HPD, closed)
I
02/24/2022
Violation issued (HPD, closed)
A
02/24/2022
Violation issued (HPD, closed)
I
04/08/2021
Violation issued (HPD, closed)
A
06/11/2020
Violation issued (HPD, open)
C
06/11/2020
Violation issued (HPD, open)
B
06/11/2020
Violation issued (HPD, closed)
C
06/11/2020
Violation issued (HPD, open)
B
10/29/2019
Violation issued (HPD, closed)
I
11/21/2017
Violation issued (HPD, closed)
I
09/14/2017
Violation issued (HPD, closed)
C
09/14/2017
Violation issued (HPD, open)
B
09/14/2017
Violation issued (HPD, open)
B
12/13/2011
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
04/27/2009
Violation issued (ECB, closed)
Construction
01/03/2008
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
01/19/2007
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
01/06/2006
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
08/16/1993
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsPermit IssuedSUPERIOR FIRE CONTROL INC12/01/2023
BISBLISSUEDWATSON'S PLBG, HTG, & BDG06/21/2017
BISPLISSUEDWATSON'S PLBG, HTG, & BDG06/21/2017
BISOTISSUEDT&S HOME IMPROVEMENT INC04/18/2017
BISPLISSUEDBARMOR REHAB INC04/18/2017
BISCCISSUEDL & C BUILDERS09/18/2003
1 project · most recent 11/27/2023
Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
11/27/2023Permit IssuedSUPERIOR FIRE CONTROL INCVentilation Systems
Ventilation
Pen Vent USBI18DD 1,500 CFM · Kitchen Exhaust ×1
Nothing on file for this building.
▾Documents — 39 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/26/2026B00966194-I1Request digital key ↗
▸Applications & Permits9
▸BISWORK PERMIT APPLICATION5
06/22/2017340494272Open ↗
04/17/2017340494272Open ↗
04/17/2017340494272Open ↗
Showing 3 of 5 on file for this type
▸BISPLAN / WORK APPROVAL APPLICATION4
01/09/2018340494272Open ↗
05/08/2017340494272Open ↗
04/21/2017340494272Open ↗
Showing 3 of 4 on file for this type
▸Seals & Professional Certifications6
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION2
04/24/2019340494272Open ↗
04/24/2019340494272Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
04/17/2017340494272Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
04/17/2017340494272Open ↗
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION1
04/17/2017340494272Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/26/2026B00966194-I1Open ↗
▸Trade Schedules & Equipment6
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE2
01/09/2018340494272Open ↗
05/08/2017340494272Open ↗
▸BISSCHEDULE B - PLUMBING2
04/21/2017340494272Open ↗
04/17/2017340494272Open ↗
▸BISPLUMBING - SUPPORTING DOCUMENTATION1
04/24/2019340494272Open ↗
▸BISSCHEDULE C - HEATING & COMBUSTION EQUIPMENT1
04/17/2017340494272Open ↗
▸Environmental & Asbestos2
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
04/17/2017340494272Open ↗
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/26/2026B00966194-I1Open ↗
▸Energy Compliance5
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS2
04/24/2019340494272Open ↗
04/24/2019340494272Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY1
04/17/2017340494272Open ↗
▸BISAS-BUILT ENERGY ANALYSIS1
04/24/2019340494272Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY FOR ENERGY CODE PROGRESS INSPECTIONS1
04/17/2017340494272Open ↗
▸Inspections & Test Reports2
▸BISTECHNICAL REPORT: RESPONSIBILITY1
04/17/2017340494272Open ↗
▸BISINSPECTION REPORT - SUPPORTING DOCUMENTATION1
04/24/2019340494272Open ↗
▸Approvals, Objections & Sign-offs1
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
04/24/2019340494272Open ↗
▸Cost, Insurance & Ownership2
▸BISCOST AFFIDAVIT2
04/24/2019340494272Open ↗
04/17/2017340494272Open ↗
▸Filing & Intake Forms5
▸BISADDITIONAL INFORMATION3
01/09/2018340494272Open ↗
06/13/2017340494272Open ↗
05/08/2017340494272Open ↗
▸BISEFILING JOB APPLICATION COVER SHEET1
04/17/2017340494272Open ↗
▸BISBOROUGH INTAKE FORM1
04/24/2019340494272Open ↗