← Back
BuildNYC
Elevator apt, fireproof without stores
Starrett City
160 SCHROEDERS AVENUE · BIN 3343606
💬 Discuss this project
1975Year Built
17Stories
D3Building Class
R5Zoning
1,420,000 sfGross Floor Area
2,229Units
LL97 CoveredRent Stabilized16 Active Violations ▸FISP: SAFEFDNY Report ↗
Elevator apt, fireproof without stores · Owner of record: BSC Housing Company · 854,159 sf lot · 1.66 FAR built · Flood zone AE
Locations of Work
ArchitectureStructuralPlumbingEquipmentGeneral
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
RoofBsc Housing Company, INC1p · 1 filing · 14 docs
Floor 1Bsc Housing Company, INC10p · 1 filing · 8 docs
Site & exteriorBsc Housing Company, INC9p · 2 filings · 17 docs
Filed — no permit issuedBsc Housing Company, INC15p · 1 filing · 9 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
Starrett City603/21/2026
BSC Owner403/21/2026
Grenadire Realty403/21/2026
BSC Housing Company203/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
New York & Company202/04/2025
2LS Consulting Engineering108/30/2023
Sandeep Gunnala Engineering108/18/2023
Cowley Engineering212/21/2022
Stavros I. Malliaros, P.E106/23/2022
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
Theresa Voltaggio203/21/2026
Core Consultants NYC203/21/2026
Bay Restoration203/21/2026
New York & Company403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
Bay Restorationspecialty_contractor203/21/2026
Bay RestorationScaffold107/08/2026
Advanced Plumbing MechanicalPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
New York Engineering Associates851202/04/2025
Sandeep Gunnala Engineering8482208/30/2023
Cowley Engineering186212/21/2022
Building Lifecycle
All (103)Filed (7)Permit Issued (3)Signed Off (3)Facade (FISP) (13)Violation (60)Inspection (3)Special Inspection (14)
01/03/2026
Violation issued (HPD, closed)
C
12/21/2025
Violation issued (HPD, closed)
C
03/28/2025
Signed off — Alteration
REGISTER GAS DRYERS. (BUILDING G5)
B01094897-I1
03/25/2025
Violation issued (HPD, closed)
B
02/04/2025
Filed — Alteration
REGISTER GAS DRYERS. (BUILDING G5)
B01094897-P3
02/04/2025
Special inspection requirement — Tenant Protection Plan Compliance
LOUIS ARENA
01/29/2025
Special inspection requirement — Tenant Protection Plan Compliance
LOUIS ARENA
11/13/2024
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
10/18/2024
Violation issued (HPD, closed)
C
10/18/2024
Violation issued (HPD, closed)
C
10/08/2024
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
09/26/2024
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
09/06/2024
Permit issued — Plumbing
B01094897-I1-PL
08/30/2024
Filed — Alteration
REGISTER GAS DRYERS. (BUILDING G5)
B01094897-I1
05/03/2024
Violation issued (HPD, closed)
B
05/03/2024
Violation issued (HPD, closed)
C
05/03/2024
Violation issued (HPD, closed)
B
05/03/2024
Violation issued (HPD, closed)
B
08/30/2023
Filed — Alteration
PLUMBING WORK IN CONJUCTION WITH GC/EA #B00907611
B00907611-S1
08/29/2023
Special inspection requirement — Tenant Protection Plan Compliance
Sandeep Gunnala
08/18/2023
Filed — Alteration
PLUMBING WORK IN CONJUCTION WITH GC/EA #B00907611
B00907611-I1
08/18/2023
Special inspection requirement — Tenant Protection Plan Compliance
Sandeep Gunnala
07/27/2023
Special inspection requirement — Post-installed Anchors
Sandeep Gunnala
07/27/2023
Special inspection requirement — Concrete - Cast-In-Place
Sandeep Gunnala
07/20/2023
Special inspection requirement — Final
Sandeep Gunnala
05/19/2023
Cycle 9 facade report signed — SAFE
02/22/2023
Cycle 9 facade report submitted
02/08/2023
Violation issued (HPD, closed)
C
01/05/2023
Cycle 9 facade inspection completed
12/27/2022
Signed off — Alteration
Facade Repairs as per plans filed herewith. No change to use, egress, or occupancy.
B00624830-I1
12/21/2022
Filed — Alteration
Facade Repairs as per plans filed herewith. No change to use, egress, or occupancy.
B00624830-P1
12/21/2022
Special inspection requirement — Structural Stability – Alterations of existing buildings
Eric Cowley
12/21/2022
Special inspection requirement — Final
Eric Cowley
12/21/2022
Special inspection requirement — Post-installed Anchors
Eric Cowley
12/16/2022
Special inspection requirement — Structural Stability – Alterations of existing buildings
Eric Cowley
12/16/2022
Special inspection requirement — Post-installed Anchors
Eric Cowley
12/16/2022
Special inspection requirement — Final
Eric Cowley
09/13/2022
Signed off — Alteration
ALTERATION TYPE 3 - CONSTRUCTION EQUIPMENT - SIDEWALK- SHED PROPOSED INSTALLATION OF HEAVY DUTY SIDEWALK SHED. NO CHANGE IN USE OCCUPANCY OR EGRESS UNDER THIS APPLICATION. LIVE LOAD 300 PER SQUARE FEET. SIDEWALK SHED SHALL COMPLY WITH CHAPTER # 33.
B00748364-I1
08/19/2022
Violation issued (ECB, closed)
Construction
07/06/2022
Permit issued — Sidewalk Shed
B00748364-I1-SH
06/23/2022
Filed — Alteration
ALTERATION TYPE 3 - CONSTRUCTION EQUIPMENT - SIDEWALK- SHED PROPOSED INSTALLATION OF HEAVY DUTY SIDEWALK SHED. NO CHANGE IN USE OCCUPANCY OR EGRESS UNDER THIS APPLICATION. LIVE LOAD 300 PER SQUARE FEET. SIDEWALK SHED SHALL COMPLY WITH CHAPTER # 33.
B00748364-I1
06/02/2022
Permit issued — General Construction
B00624830-I1-GC
05/31/2022
Special inspection requirement — Final
STAVROS MALLIAROS
04/22/2022
Violation issued (HPD, closed)
C
04/22/2022
Violation issued (HPD, closed)
C
03/02/2022
Filed — Alteration
Facade Repairs as per plans filed herewith. No change to use, egress, or occupancy.
B00624830-I1
05/20/2021
Violation issued (ECB, closed)
Elevators
12/17/2020
Violation issued (HPD, closed)
A
12/17/2020
Violation issued (HPD, closed)
B
12/17/2020
Violation issued (HPD, closed)
B
09/24/2020
Violation issued (HPD, closed)
A
09/24/2020
Violation issued (HPD, closed)
A
09/24/2020
Violation issued (HPD, closed)
A
10/31/2019
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
11/09/2018
Violation issued (HPD, closed)
C
10/10/2018
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
04/30/2018
Cycle 8 facade report signed — SAFE
04/10/2018
Cycle 8 facade inspection completed
01/26/2018
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
10/27/2017
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
Latest 60 of 103 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offAdvanced Plumbing Mechanical09/06/2024
DOB NOWSidewalk ShedSigned-offBay Restoration07/06/2022
DOB NOWGeneral ConstructionSigned-offBay Restoration06/02/2022
BISEQISSUEDAdvanced Construction Equipment11/02/2012
BISEQISSUEDAdvanced Construction Equipment08/28/2012
BISOTISSUEDAllstate Restoration08/22/2012
BISOTISSUEDAllstate Restoration05/04/2007
BIS—ISSUEDMartin Fleming Gen. Contractor I06/08/2001
BISOTISSUEDNJK Contracting05/11/2001
BISOTISSUEDNJK Contracting03/21/2001
BISEQRE-ISSUEDBridgeworks09/14/1993
1 project · most recent 08/30/2023
Water/Sanitary
FiledStatusContractorScope
08/30/2023——Water/Sanitary
1 project · most recent 08/30/2023
FiledStatusContractorScope
08/30/2023——1 scope_items
▾Field Inspections (DOB CAP) — 3
DateTypeResultReport
11/13/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
10/08/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
09/26/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
▾Special Inspection Requirements (DOB NOW) — 14
DateRequirementInspectorRole
02/04/2025Tenant Protection Plan ComplianceLOUIS ARENAspecial
01/29/2025Tenant Protection Plan ComplianceLOUIS ARENAspecial
08/29/2023Tenant Protection Plan ComplianceSandeep Gunnalaspecial
08/18/2023Tenant Protection Plan ComplianceSandeep Gunnalaspecial
07/27/2023Post-installed AnchorsSandeep Gunnalaspecial
07/27/2023Concrete - Cast-In-PlaceSandeep Gunnalaspecial
07/20/2023FinalSandeep Gunnalaprogress
12/21/2022Structural Stability – Alterations of existing buildingsEric Cowleyspecial
12/21/2022FinalEric Cowleyprogress
12/21/2022Post-installed AnchorsEric Cowleyspecial
12/16/2022Structural Stability – Alterations of existing buildingsEric Cowleyspecial
12/16/2022Post-installed AnchorsEric Cowleyspecial
12/16/2022FinalEric Cowleyprogress
05/31/2022FinalSTAVROS MALLIAROSprogress
▾Documents — 73 on file (BIS + DOB NOW)
▸Plans & Drawings7
▸DOB NOWPlans/Sketch7
08/31/2026B00624830-I1Request digital key ↗
08/31/2026B00624830-P1Request digital key ↗
08/29/2026B00748364-I1Request digital key ↗
Showing 3 of 7 on file for this type
▸Applications & Permits15
▸BISPLAN / WORK APPROVAL APPLICATION12
09/27/2022301149987Open ↗
09/27/2022301149987Open ↗
09/12/2022301149987Open ↗
Showing 3 of 12 on file for this type
▸BISWORK PERMIT APPLICATION3
11/05/2012320507233Open ↗
08/29/2012320507233Open ↗
08/23/2012320392286Open ↗
▸Seals & Professional Certifications26
▸DOB NOWSpecial Inspector Seal & Signature8
10/03/2026B00624830-P1Open ↗
10/03/2026B00624830-P1Open ↗
09/23/2026B00624830-I1Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature7
08/31/2026B00624830-P1Open ↗
08/31/2026B00624830-I1Open ↗
08/26/2026B00907611-S1Open ↗
Showing 3 of 7 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION5
12/13/2012320507233Open ↗
08/29/2012320507233Open ↗
11/14/2011320392286Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWProgress Inspector Seal & Signature4
10/03/2026B00624830-P1Open ↗
09/23/2026B00624830-I1Open ↗
09/01/2026B00907611-I1Open ↗
Showing 3 of 4 on file for this type
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
08/29/2012320507233Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM1
08/29/2012320507233Open ↗
▸Environmental & Asbestos4
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'2
11/14/2011320392286Open ↗
11/14/2011320392286Open ↗
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/31/2026B00624830-P1Open ↗
08/31/2026B00624830-I1Open ↗
▸Energy Compliance1
▸BISTECHNICAL REPORT: ENERGY1
11/14/2011320392286Open ↗
▸Approvals, Objections & Sign-offs15
▸DOB NOWFee Exempt Supporting Document - DOF ACRIS report or BIB letter6
08/31/2026B00624830-I1Open ↗
08/31/2026B00624830-P1Open ↗
08/24/2026B01094897-P3Open ↗
Showing 3 of 6 on file for this type
▸BISSCHEDULE A - OCCUPANCY / USE4
09/09/2022301149987Open ↗
08/04/2022301149987Open ↗
07/29/2022301149987Open ↗
Showing 3 of 4 on file for this type
▸BISLETTERS - SUPPORTING DOCUMENTATION2
06/21/2022301149987Open ↗
05/20/2022301149987Open ↗
▸BISADMINISTRATIVE OBJECTIONS2
08/29/2012320507233Open ↗
11/14/2011320392286Open ↗
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
12/13/2012320507233Open ↗
▸Cost, Insurance & Ownership2
▸BISCOST AFFIDAVIT2
12/08/2012320392286Open ↗
11/14/2011320392286Open ↗
▸Filing & Intake Forms3
▸BISEFILING COVER SHEET2
08/29/2012320507233Open ↗
11/14/2011320392286Open ↗
▸BISADDITIONAL INFORMATION1
01/18/2019301149987Open ↗