DOB06/23/2024Failure to submit an eer per ad. Code sec. 28-308.4 - multiple years (2023)
ECB04/19/2024Failure to file acceptable amended cycle 8C and 9C report indicating correction of unsafe conditons described in initial facades report required by 28-302.5 for control #914172. Remedy: file acceptable report.$6K due
ECB04/12/2023Class 1 item: missing dlm as now required by code. Class 2 items: replace worn gibs where needed. Inoperative car phone. Shorten governor rope. Buffers missing 5 year tag. Missing in case of fire signs. Remove$6K due
ECB04/12/2023Class 1 item: missing dlm as now required by code. Class 2 items: replace worn gibs where needed. Inoperative car phone. Shorten governor rope. Buffers missing 5 year tag.$6K due
ECB03/06/2020No door lock monitoring installed in this controller as mandated by 3.10.12 of appendix K3 of the 2014 nycbc. This is a controller feature which ensures passenger safety. Remedy; file application, install dlm a2 identical filings$1K due
ECB05/31/2011Work does not conform to approoved construction documents for new BLDGNB301774195.nonconforming elements noted:@west end of parking lot,drawing deficts the north facing retaining/curb wall w/a 6INCH reveal abovNothing owed — awaiting certificate of correction
ECB03/05/2009Failure to maintain building in code-compliant manner. Noted: concrete retaining wall,approx 4"-5'h at rear of building,separating parking lot from adjacent properties,has numerous vertical cracks & continuousNothing owed — awaiting certificate of correction
Likely answered · the city's own records show a filing, but DOB's feed still lists these as active
DOB11/14/2025Violation issued-failure to file 2024 external low pressure inspectionThe owner has filed since: boiler inspection reports are on file for later years (latest 2025). This one is not shown as answered
DOB09/23/2024Violation issued-failure to file 2023 external low pressure inspectionThe owner has filed since: boiler inspection reports are on file for later years (latest 2025). This one is not shown as answered
DOB09/06/2019Vio issued to elevator - fail to correct defects on 2017 cat 1 insp/tst tstThe owner has filed since: Category 1 elevator reports are on file for later years (latest 2025). This one is not shown as answered2 identical filings
Old · issued 3+ years ago and still listed by DOB; nothing on the city's records either way
DOB10/04/2023Failure to certify correction on immediately hazardous (class 1) ECB violationIssued 2023; DOB's record still lists it as active2 identical filings
DOB04/22/2023Failure to submit an eer per ad. Code sec. 28-308.4 in 2022Issued 2023; DOB's record still lists it as active
DOB09/02/2020Failure to certify correction on immediately hazardous (class 1) ECB violationIssued 2020; DOB's record still lists it as active2 identical filings
DOB08/02/2020Failure to file benchmarking report of energy use as per ad. Code sec. 28-309.4Issued 2020; DOB's record still lists it as active
DOB05/02/2020Failure to file benchmarking report of energy use as per ad. Code sec. 28-309.4Issued 2020; DOB's record still lists it as active
DOB02/02/2020Failure to file benchmarking report of energy use as per ad. Code sec. 28-309.4Issued 2020; DOB's record still lists it as active
DOB11/02/2019Failure to file benchmarking report of energy use as per ad. Code sec. 28-309.4Issued 2019; DOB's record still lists it as active
DOB08/02/2019Failure to file benchmarking report of energy use as per ad. Code sec. 28-309.4Issued 2019; DOB's record still lists it as active
DOB05/02/2019Failure to file benchmarking report of energy use as per ad. Code sec. 28-309.4Issued 2019; DOB's record still lists it as active
DOB04/30/2019Failed to file FISP cycle 8C technical report by 02/21/2019Issued 2019; DOB's record still lists it as active
DOB02/16/2019Failure to file benchmarking report of energy use as per ad. Code sec. 28-309.4Issued 2019; DOB's record still lists it as active